Page 3
Upgrade Tab ......................................37 7.5.1 Upgrading the ASMM ...................................38 7.5.2 Upgrading Other Modules ................................38 LED Status Indicators ...............................39 Status Parameter List and Alarm Limits ........................41 10 Declaration of Conformity ............................42 Appendix A: dB Conversion Table ..........................43 Aug/2017 - V1 Technetix Group Limited...
Technetix.NMS3-EPSM - Basic Alarm Management Technetix.NMS3-EPSM - Basic System Management Technetix.NMS3-EPSM - Basic Template Management 1.2 Technical Support Please contact the technical support team at Technetix if you have any problems during ASMM Module installation or maintenance. Europe: Technetix BV...
Outage or overload requiring service and repairs Unplug the unit and refer the servicing to Technetix qualified service personnel only. Servicing and repairs DO NOT attempt to service this unit yourself. Refer all servicing needs to Technetix qualified service personnel only. Aug/2017 - V1...
3 Overview 3.1 About the Product The AIMA3000 System Management Module (ASMM) is the system controller module for the Technetix latest generation Advanced Intelligent Multi-services Access Platform - the AIMA3000. The ASMM control module supervises all Application Modules (AMs), power supplies, and fan modules within the AIMA3000 chassis.
Module reset button LOCAL RJ45 10/100BaseT Ethernet connector CONSOLE Micro-USB Device Type B connector (used by Technetix support engineers) USB Host Type A connector Communications interface (rear panel) Alarm relay contacts Common, N/C and N/O contacts, 0.5 A, 40 Vac or Vdc maximum...
LED status indicators (see Section 6) RST - module reset button* Orange tab-retaining clip LOCAL - RJ-45 10/100BaseT Ethernet connector CONSOLE – Micro USB Device Type B connector (for Technetix support use only) USB - Host Type A connector Module retaining screw Note: (*)The reset button performs a hardware reset of the ASMM module.
- NC (Normally Closed) - NO (Normally Open) NET MGMT (RJ-45 Ethernet Port 0) NET MGMT (RJ-45 Ethernet Port 1) LAN Activity LEDs (green): On - Link established Flashing - Link active Off - No link established Aug/2017 - V1 Technetix Group Limited...
-5 ºC to +55 ºC with the AIMA3000 fans running. Should the temperature exceed the above limits, the AIMA3000 should be relocated in the equipment rack where the ambient temperature is less than 55 ºC. Aug/2017 - V1 Technetix Group Limited...
The ASMM module should be the first module installed and must be fitted into slot 0 of the AIMA3000 chassis. Installing the Module Gently depress the orange retaining clip and release the hinged tab Hinged tab AIMA Module Orange retaining clip Aug/2017 - V1 Technetix Group Limited...
Page 14
When the module is fully seated within the chassis, on the bottom of the AIMA module, fasten the spring- loaded mounting screw. Only use fingers to fasten the mounting screw. DO NOT use a screwdriver. Aug/2017 - V1 Technetix Group Limited...
To avoid damage, do not pull the module by only using the hinged tab. Whenever the module is removed or inserted from the chassis, secure the hinged tab in the closed position behind the orange retaining clip. Aug/2017 - V1 Technetix Group Limited...
5.6 ASMM Connections On the rear panel, connect the: ■ RJ-45 Ethernet Port 0 to a local network switch for network management using Technetix NMSE or a third-party management software. ■ You can also connect the RJ-45 Ethernet Port 1 of the primary ASMM module to Port 0 on the rear panel of a secondary/slave ASMM module in another AIMA3000 chassis to create a daisy chain.
Configuration using an Android device The Android application may not be compatible with all Android devices. The app was developed by Technetix to be used in conjunction with a Lenovo Ideapad A1 07 running Android 2.3.4 Gingerbread. Before installing the application, the installation of unknown sources must be enabled by going to settings >...
Page 18
Product User Manual AIMA3000.ASMM Select the tethering and portable hotspot. Enable USB tethering. Aug/2017 - V1 Technetix Group Limited...
Page 19
A1 07 running Android 2.3.4 Gingerbread assigns 192.168.42.1 by default. This address will vary between devices and manufacturers. The ASMM login page will pop up. Enter the login (default login: admin) and password (default password: Technetix). Passwords are case sensitive. Aug/2017 - V1 Technetix Group Limited...
The ASMM module is controlled via a web interface, by first entering the AIMA3000’s web server IP address in your browser’s address bar. You must then log in to the server by entering your username and password in the pop-up dialogue box that appears. Aug/2017 - V1 Technetix Group Limited...
This will erase all configuration settings and reboot the AIMA3000 with its factory default settings. Backup and Restore AIMA Configuration Backup Download Configuration to a local file. Configuration File Browse to choose a previously saved configuration file. Aug/2017 - V1 Technetix Group Limited...
Page 22
Product User Manual AIMA3000.ASMM Restore Configuration using the chosen configuration file. Reboot button Reboot will take approximately 15 seconds to complete. RF Units dBuV Module Export No initial setting Aug/2017 - V1 Technetix Group Limited...
The System page allows for confi guring for an ASMM’s name, location, and contact information. 7.1.2 Network Confi guration The Network Confi guration page allows an administrator to set an IP address, Net mask, and Gateway. Aug/2017 - V1 Technetix Group Limited...
Product User Manual AIMA3000.ASMM SNMP Confi guration The SNMP Confi guration page is used to set simple network management protocol traps. Aug/2017 - V1 Technetix Group Limited...
7.1.3 TFTP Server The TFTP Server page allows administrators to specify a TFTP Server for module management. This feature only works in conjunction with Technetix NMSE management software. * NMSE is required for the feature * The TFTP rules are confi gured within NMSE, refer to the NMSE Product User Manual for more details...
7.1.4 Syslog Server The Syslog Server page allows administrators to specify an IP address for exporting a system log fi le. This feature only works in conjunction with Technetix NMSE management software. * NMSE is required for the feature Aug/2017 - V1...
Product User Manual AIMA3000.ASMM 7.1.5 User Management The User Management page allows for additional accounts and permissions to be set, created, or modifi ed. Aug/2017 - V1 Technetix Group Limited...
Date and Time The Date and Time page allows administrators to specify a time zone and NTP server allowing the time to be set automatically. Note: There is no default NTP Server specifi ed. Aug/2017 - V1 Technetix Group Limited...
The Factory Defaults page is used to reset all the module settings. It is recommended to backup the current confi guration before resetting the ASMM's settings and alarm parameters. By checking the "Delete All File" check box, it will clear all module confi gurations. Aug/2017 - V1 Technetix Group Limited...
* The Web GUI above only supports the manual operation from a local PC. * The ASMM supports automated fi rmware updates and automatic backup & restore features via TFTP when managed via Technetix NMSE management software. Please refer to the NMSE Product User Manual for more information.
AIMA3000.ASMM 7.1.8 Reboot The Reboot page allows the ASMM to be restarted by simply clicking the Reboot button. 7.1.9 Additional Function Select interface language, set the default units, and exports module characteristics and parameters. Aug/2017 - V1 Technetix Group Limited...
ASMM’s database for future use. You can also view the current Provisioned Confi guration of a module, by clicking on the associated link. To view a page showing specifi c module information, click view under Provisioned Confi guration. Aug/2017 - V1 Technetix Group Limited...
In the Alarm Settings panel, you can view alarm parameter names and the associated settings. 7.2.2 Other Modules Module Information, Confi guration, and Alarm Settings information for other module types can be found in the associated module's manual. Aug/2017 - V1 Technetix Group Limited...
A table to the right of the list shows the current alarm status for all installed modules. Click on the Refresh button to update the table. 7.3.1 ASMM Alarms Click on the ASMM module from the left column of the Alarms page. Aug/2017 - V1 Technetix Group Limited...
If there is more than one page of events, use the Page Up and Page Down links to view other pages. Note: The ASMM can handle no more than 1000 logs Aug/2017 - V1 Technetix Group Limited...
Click on the Upgrade tab on the top menu bar. On the All Modules page, you can view HW/FW assembly number and the current FW version of each installed module. Click on the Refresh button to update the table. Aug/2017 - V1 Technetix Group Limited...
* The Web GUI above only supports the manual operation from a local PC. * The ASMM supports automated fi rmware updates and automatic backup & restore features via TFTP when managed via Technetix NMSE management software. Please refer to the NMSE Product User Manual for more information.
The mode LED is static green, when the slots in 'Hotswap Mode' are all auto mode Flashing amber: Upgrading ASMM firmware Flashing amber: Upgrading AM firmware Static red: HIHI or LOLO alarm; unsynchronised configuration alarm; communications failure Static amber: HI or LO alarm Aug/2017 - V1 Technetix Group Limited...
Page 39
Flashing amber: Upgrading PS2 firmware Static red: FAN Major Alarm Static amber: FAN Minor alarm * When either PS1 or PS2 is missing the STAT LED will appear green for that specific power supply Aug/2017 - V1 Technetix Group Limited...
ASMM Common parameters (not configurable) Threshold Dead Default alarm Parameter Units HIHI Normal LOLO changeable Band enable by user Temperature °C +5V Input Voltage Note: The above parameter values cannot be changed by the user. Aug/2017 - V1 Technetix Group Limited...
10 Declaration of Conformity According to ISO/IEC Guide 22 and EN45014 Manufacturer's Name: Technetix Manufacturer’s Address: Technetix Ltd, Innovation House, Technetix Business Park, Albourne, West Sussex, BN6 9EB Product Name: ASMM – AIMA System Management Module Conforms to the following standards:...