Download Print this page
Aiphone LEF-LD Instructions
Aiphone LEF-LD Instructions

Aiphone LEF-LD Instructions

Lef loudspeaker intercom system for long distance and elevator applications

Advertisement

Quick Links

LEF Loudspeaker Intercom System for Long Distance and Elevator Applications
LEF-3-LD, LEF-3L-LD, LEF-5-LD, LEF-10-LD, LEF-10S-LD
The LEF-LD system is designed with the capability to operate at greater distances and for use in
elevators. The sub stations are available in either surface or flush mount styles. Any LEF, LAF-C/CA, or
LDF master can be modified for Long Distance. This is a SINGLE MASTER SYSTEM ONLY. EXTERNAL
SIGNALING WITH THE RY-AC/A RELAY IS NOT SUPPORTED ON THIS SYSTEM.
IMPORTANT:
Only the IF-DA-LD, IE-JA-LD, IE-SS-LD and IE-SSR-LD will function with these "LD" type master stations. Standard
LE- or LS-series sub stations cannot be used with LEF-LD master stations. In addition, the remote stations listed
above will only function with the "LEF-LD, LAF-LD or LDF-LD" model master stations.
Installation Examples:
IF-DA-LD Mounting:
LEF Master Terminal Definitions:
1~10
Selective call/communication
terminal for each call button
E
Common communication
+
12V DC
-
Negative, common call signal
IF-DA-LD Sub Terminal Definitions:
1
Call-in and Communication
2
Common
White
+12V DC (connect to + of PS-1225UL)
WIRING DIAGRAMS:
Method A:
3 conductors homerun
from master to each sub.
Note:
The jumper between E & -
must remain attached on the
master station.
LEF-3C-LD, LEF-5C-LD, LEF-10C-LD
- INSTRUCTIONS -
IE-JA-LD Mounting:
IE-JA-LD
1
2
3
-
+
PS-1225UL
screws
IE-JA-LD Sub Terminal Definitions:
1
Call-in and Communication
2
Common
3
+12V DC (connect to + of PS-1225UL)
IE-SS(R)-LD Sub Wire Definitions:
Red
Call-in and Communication
Black
Common
White
+12V DC (connect to + or PS-1225UL)
Wiring Distance: 22 AWG = 2000'; 18 AWG = 4000'
Use Aiphone #822202 or #821802 wire.
LEF-5-LD
IF-DA-LD
1
2
3
~
5
E
-
+
NOTE: "C" terminal of the
master station is not used
in this system.
IE-SS(R)-LD Mounting:
TORX
IE-SS(R)-LD
1
Red
Blk
2
Wht
Wht
Pg. 1

Advertisement

loading

Summary of Contents for Aiphone LEF-LD

  • Page 1 Only the IF-DA-LD, IE-JA-LD, IE-SS-LD and IE-SSR-LD will function with these “LD” type master stations. Standard LE- or LS-series sub stations cannot be used with LEF-LD master stations. In addition, the remote stations listed above will only function with the "LEF-LD, LAF-LD or LDF-LD" model master stations.
  • Page 2 Pressing the call button at the remote station will activate the call tone, plus light the appropriate station LED at the LEF-LD master. The call tone will be momentary as long as the call button is held down, and the LED light will stay on for approximately 20 seconds.

This manual is also suitable for:

Lef-3-ldLef-3l-ldLef-5-ldLef-10-ldLef-10s-ldLef-3c-ld ... Show all