Summary of Contents for Campbell GRANITE

  • Page 1 GRANITE CHASSIS Chassis for GRANITE Data-Acquisition Systems 04/2021 Copyright © 2021 Campbell Scientific, Inc.
  • Page 2: Table Of Contents

    Table of contents 1. Introduction 2. Precautions 3. Initial inspection 3.1 Inspect packaging 3.2 GRANITE CHASSIS parts 4. QuickStart 5. Overview 6. Specifications 6.1 Physical specifications 6.2 Electrical specifications 7. Mounting and installation 7.1 Recommended module locations 7.2 GRANITE modules 7.3 Orientation...
  • Page 3: Introduction

    1. Introduction The GRANITE™CHASSIS is a strong metal enclosure that delivers optimized thermal management and mounting convenience for a collection of GRANITE-series data acquisition (DAQ) modules. As a system that includes a rechargeable backup battery, it can be portable or stationary. Power can be supplied by AC or DC sources such as solar or rackmounted wall-power.
  • Page 4: Precautions

    To avoid ground loops, only allow a single path to ground. The second grounding lug is intended to connect subsequent devices that need to be grounded, such as one or more daisy-chained CHASSIS or GRANITE modules that are mounted external to the CHASSIS.
  • Page 5: Initial Inspection

    3. Initial inspection 3.1 Inspect packaging Upon receiving the GRANITE CHASSIS, inspect the packaging and contents for damage. Claims for shipping damage must be filed with the shipping company. Locate the order packing slip and compare the items listed on the packing slip to the items that were shipped.
  • Page 6: Granite Chassis Parts

    3.2 GRANITE CHASSIS parts Each CHASSIS is shipped with a box of tools and parts used to install GRANITE DAQ and measurement modules (purchased separately). The following table shows the common parts and tools used in CHASSIS setup. Some of the items should be saved for future use.
  • Page 7: Quickstart

    Turn power off while installing hardware and making electrical connections. Set the CH400 Power Switch to Off before starting installation. 1. Use a #2 Phillips Screwdriver to loosen screws for module mounting. NOTE: Mounting screws only need to be loosened two to three turns. GRANITE CHASSIS 5...
  • Page 8 2. Mount the CH400, if used, in left-most position, otherwise mount GRANITE DAQ here. Mount other measurement modules. See Mounting and installation (p. 11) for more details. FIGURE 4-1. Typical CHASSIS setup 3. Using the Flat-Bladed Screwdriver press firmly in the small slot of the Green 4-Pin Terminal Connector to open the wire slot.
  • Page 9: Overview

    CH400 (see FIGURE 4-1 (p. 6)) or other regulator such as the one built- in to the GRANITE 6 DAQ. See the following figure. For complex battery configurations refer to the CH400 product manual. GRANITE CHASSIS 7...
  • Page 10 FIGURE 5-1. Typical wiring for GRANITE 6 Features: Three CHASSIS power configuration options: 36 VDC, 600 W AC/DC Power Supply 24 VDC, 250 W AC/DC Power Supply No internal power supply User-customizable top and rear panels Configurable layout High-performance operations even at maximum operating temperatures...
  • Page 11: Specifications

    31.0 cm (12.21 in) Height (H) 25.3 cm (9.95 in) 24.4 cm (9.61 in) Weight CHASSIS only, no battery: 10.6 kg (23.3 lb) Battery: 3.0 kg (6.7 lb) CHASSIS with GRANITE modules (typical): 20.4 kg (45.0 lb) GRANITE CHASSIS 9...
  • Page 12: Electrical Specifications

    30 mA when on Battery: 12 VDC, 8 Ah, AGM sealed lead-acid in metal casing Maximum recommended storage time before recharge: 24 months at 25 °C or 12.0 VDC, whichever is earlier Atmospheric pressure range: Vacuum to 8 atmospheres GRANITE CHASSIS 10...
  • Page 13: Mounting And Installation

    To deliver optimal thermal performance where maximum heat dissipation is needed, mount the CH400 (when used) in the position furthest to the left as shown in the following image. For wiring convenience, mount the DAQ (GRANITE 6, GRANITE 9, GRANITE 10) next to the CH400. Mount measurement modules in remaining locations. When observing these mounting recommendations, the battery temperature is reduced, improving performance.
  • Page 14: Granite Modules

    7.2 GRANITE modules GRANITE modules mount in the CHASSIS using pre-installed anti-vibration screws; they simply need to be tightened when GRANITE modules are installed. If a screw is damaged, or the anti- vibration patch wears off, it may be replaced.
  • Page 15: Tie-Downs

    Leave slack in fixed cables, such as sensor cables, to allow for cable movement. Use a cable management arm (purchased separately) to keep cable bundles organized and movable. 7.5 Tie-downs Four ear loops on the CHASSIS provide anchor points to secure the CHASSIS. FIGURE 7-2. Ear loop locations GRANITE CHASSIS 13...
  • Page 16: Wiring

    8.3 Routing user-installed cables 8.1 Grounding CHASSIS It is not necessary to use ground lugs on the rear of the GRANITE modules as long as the GRANITE modules are clamped down tightly to the CHASSIS frame. In most cases, use a single ground path to avoid ground loops.
  • Page 17 The Temp cord, with stereo plug, reads a temperature sensor mounted next to the internal CHASSIS battery. This cord plugs into the BATT A Temperature or BATT B Temperature port on the CH400. When the CH400 is not used, tie this cable out of the way. GRANITE CHASSIS 15...
  • Page 18: Routing User-Installed Cables

    Solid aluminum top and rear panels are removable. Take out the four Phillips screws in each top panel to remove them. For the rear panel, loosen the Phillips screws to slide it up and off the keyhole mounting slots. GRANITE CHASSIS 16...
  • Page 19 FIGURE 9-1. Top panels FIGURE 9-2. Rear panel The removable panels can be customized by Campbell Scientific or others. For example, add cutouts for quick-attach connectors. Speak with a Campbell Scientific Sales Engineer about customization. GRANITE CHASSIS 17...
  • Page 20: Linking Multiple Chassis

    4. Set the CH400 Power Switch to On. 11. Maintenance Keep the GRANITE CHASSIS clean and dry. The GRANITE CHASSIS can be expected to deliver many years of reliable service. Eventual maintenance includes battery and cooling fan replacements. See Battery maintenance (p.
  • Page 21: Battery Maintenance

    Before replacing the CHASSIS battery, collect all data from the DAQ. Battery replacement procedure: 1. Unplug Detachable Power Cord (if present). 2. Unplug Green 4-Pin Terminal Connector. 3. Pull knob up. 4. Partially slide drawer out. FIGURE 11-1. Battery drawer GRANITE CHASSIS 19...
  • Page 22 9. Slide the drawer in, connecting the battery plug when about half way, then slide it the rest of the way in. 10. Ensure the knob seats again completely. 11. Plug the Green 4-Pin Terminal Connector back in. 12. Plug in the Detachable Power Cord (if present). GRANITE CHASSIS 20...
  • Page 23 See Product Details on the Ordering Information pages at www.campbellsci.com . Other manufacturer's products, that are resold by Campbell Scientific, are warranted only to the limits extended by the original manufacturer. Refer to www.campbellsci.com/terms#warranty for more information.
  • Page 24 To obtain a Returned Materials Authorization or Repair Reference number, contact your CAMPBELL SCIENTIFIC regional office. Please write the issued number clearly on the outside of the shipping container and ship as directed. For all returns, the customer must provide a “Statement of Product Cleanliness and Decontamination”...
  • Page 25 WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR MAINTENANCE OF TRIPODS, TOWERS, OR...
  • Page 26 Campbell Scientific regional offices Australia France Thailand Location: Garbutt, QLD Australia Location: Vincennes, France Location: Bangkok, Thailand Phone: 61.7.4401.7700 Phone: 0033.0.1.56.45.15.20 Phone: 66.2.719.3399 Email: info@campbellsci.com.au Email: info@campbellsci.fr Email: info@campbellsci.asia Website: www.campbellsci.com.au Website: www.campbellsci.fr Website: www.campbellsci.asia Brazil Germany Location: São Paulo, SP Brazil...