Safety Target group Maintenance and repair on this product may only be performed by skilled persons in accordance with EN IEC 62079:2001. Safety notes • Use only original spare parts when making repairs • Do not modify the product or add any additional modules Explanation of symbols Table 1: Symbols in the instructions...
The infrared interface for communication with the Geberit Service Handy is located in the middle of the cover plate. To make any settings, the Geberit Service Handy must be aimed at this area from a distance of 20 to 30 cm.
Page 6
Menu item Description Application Adjustment Factory [EN] range setting [DE] Block flush. In the event of detection On = <OK> – [BlocFlush] No flush is actuated. The LED flashes malfunctions Off = <OK> [Blockiere] twice every six seconds. The function is deactivated automatically after ten hours Empty pipe.
Page 7
Table 3: Programs Menu item Description Application Adjustment Factory [EN] range setting [DE] Select covered urinal operation. When the open cover of On = [ON] Off = [OFF] [CoverOps] Switches operation with the the covered urinal Off = [OFF] [Deckel-UR] covered urinals on or off blocks the sensor Enable manual flush.
Page 8
Table 4: Parameters Menu item Description Application Adjustment Factory [EN] range setting [DE] Set flush time. Optimum flushing out of 3–15 s [...] 4 s [4] [FlshTime] Duration of the flush after one use the urinal ceramic [Spülzeit] Set detection time. Prevents flushes due to 3–15 s [...] 7 s [7]...
Page 9
Table 5: Counters Menu item Description Output [EN] [DE] Total number of days of operation. [...] days of [Days?] Displays the number of days of operation since commissioning operation [SumBetrT?] Total number of uses. [...] uses [Uses?] Displays the total number of uses since commissioning [SumBenut?] Total number of flushes.
Setting the flush time manually For battery-operated urinal flush control: disconnect the plug connection between the control and the battery for at least 20 seconds and then reconnect it. 2 mm 00:00:20 90º 90º Within five seconds hold your hand around 5 cm away from and in front of the control.
Page 16
Disconnect the plug connections for the mains-operated urinal flush control. PH 3 Disconnect the plug connections for the battery-operated urinal flush control. Connect the plug connections for the mains-operated urinal flush control. PH 3 Connect the plug connections for the battery-operated urinal flush control.