Table of Contents

Advertisement

Quick Links

Manual
MWS 3 & 485-Sensors
with Microprocessor
without datalogger
REINHARDT System- und
Messelectronic GmbH
Bergstr. 33, D-86911 Dießen-Obermühlhausen
Tel. 0049 - (0) 8196/934100
Fax 0049 - (0)8196/7005 or 1414
E-Mail:
wetter@reinhardt-testsystem.de
http://www.reinhardt-wetterstationen.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Messelectronic MWS 3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Reinhardt Messelectronic MWS 3

  • Page 1 Manual MWS 3 & 485-Sensors with Microprocessor without datalogger REINHARDT System- und Messelectronic GmbH Bergstr. 33, D-86911 Dießen-Obermühlhausen Tel. 0049 - (0) 8196/934100 Fax 0049 - (0)8196/7005 or 1414 E-Mail: wetter@reinhardt-testsystem.de http://www.reinhardt-wetterstationen.de...
  • Page 2: Table Of Contents

    3.5.1 RS232 / RS422 port .......................13 3.5.2 RS485 port ..........................14 3.6 System requirements ........................14 3.6.1 System requirements (32bit-Versions) ...................14 geändert am 03.11.2015 von DO MWS3_e Page 2 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 3 8.1.1 Input parameters of MWS 3 / 485-Sensors -Microcontroller ..........20 8.2.2 Querying the Microprocessor ....................23 8.2.3 Order of the MWS 3 sensors ....................24 9 Exchange Connectors..........................25 geändert am 03.11.2015 von DO MWS3e.p65 Page 3 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de...
  • Page 4 UVS 485 GSS 485 DFT 485 UVIS 485 FTS 485 DTS 485 WGS 485 WRS 485 RDR 485 HKS 485 geändert am 03.11.2015 von DO MWS3e.p65 Page 4 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de...
  • Page 5: Caution

    1 Caution 1.1 Intended Use The REINHARDT-Weather station MWS 3 & the 485-Sensors (in the rest of the manual always named as MWS3) are designed for stationary operation for short time measuremnts to collect climatic parameters outside. The unit must not be operated on vehicles or machines due to the...
  • Page 6: Setting Up The Weather Station

    (If you want to install the software packages directly, you will find the paths for the single installations in the install.html file.) Now you follow the instructions of the WeatherCD. geändert am 03.11.2015 von DO MWS3e.p65 Page 6 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de...
  • Page 7: Starting The Software

    Operation on a vehicle off road is not recommended due to strong vibrations and strong shocks! geändert am 03.11.2015 von DO MWS3_e Page 7 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 8: The Sensors

    This is a simple formula for reducing pressure. There are other formulas for reducing pressure to sea level. You'll find in the web. You may add one of these formulas into the Reinhardt weather software to reduce pressure with a more complex formula.
  • Page 9: The Wind Speed Sensor

    (i.e. air traffic, ...)! geändert am 03.11.2015 von DO MWS3_e Page 9 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 10: The Light Intensity Sensor Hks 485

    After being set to high the sensor RA stays high for app. 2 minutes. When a new detection is performed within these 2 minutes this countdown is restarted (retriggered). geändert am 03.11.2015 von DO MWS3e.p65 Page 10 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web:...
  • Page 11: Sensor Accuracy

    (!X1) to ensure that the sensor detects even small rain drops. The setting is set to sensitive by default. geändert am 03.11.2015 von DO MWS3_e Page 11 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 12: Power Supply

    GSS 485 ; 1.9mA, Leistungaufnahme: 34mW HKS 485 ; 1.6mA, power consumption: 29mW UVIS 485 ; 2.0mA, Leistungaufnahme: 36mW geändert am 03.11.2015 von DO MWS3e.p65 Page 12 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de...
  • Page 13: Data Format

    Every second the WKS 485 transmits a data record, which includes the light intensity in [lux]. The datastring ends with <CR><LF>. geändert am 03.11.2015 von DO MWS3_e Page 13 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 14: Rs485 Port

    Runs with WIN98 SE, WIN ME, WIN 2k, WIN XP, Vista and WINDOWS 7. Using the F1-key or the "?" in the menu bar, you can call the Online-Help at any time. geändert am 03.11.2015 von DO MWS3e.p65 Page 14 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web:...
  • Page 15: Connections And Pin Assignments

    In case you lengthen the data cable, please take care that the connections in the connector at the computer must be wired. (Connect Pin 4 to Pin6 and Pin7 to Pin8). geändert am 03.11.2015 von DO MWS3_e Page 15 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 16: Allocation Of The Connection Cable For Sensors With Rs422-Port

    > PSU-VCC (pink) 6 (R- of MWS 3) < > wire (green) 7 (T- of MWS 3) < > wire (brown) geändert am 03.11.2015 von DO MWS3e.p65 Page 16 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de...
  • Page 17: Excerpts From The Directions Of Dwd For Automatic Weather Stations

    By standard wind direction and wind speed is measured 10m above ground geändert am 03.11.2015 von DO MWS3_e Page 17 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 18: Trouble Shooting

    Caution! This log-file is overwritten each time, when the software is restarted. To keep this file, store it in another place or rename it. software. geändert am 03.11.2015 von DO MWS3e.p65 Page 18 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de...
  • Page 19: Options

    Small digital meteo display for displaying 10 parameters simultaneously with digit size 13 mm. Available for wall mounting or placing on a table. For indoor use only. geändert am 03.11.2015 von DO MWS3_e Page 19 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 20: Technical Appendix

    '!' 'KX,M0' <#13> Sensor with output-number X is not attenuated '!' 'KX,M1' <#13> Sensor with output-number X is attenuated geändert am 03.11.2015 von DO MWS3e.p65 Page 20 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de...
  • Page 21 In SECURE-mode no address is needed for commands, even when the sensor is set to RS485 mode!! The EEPROM-write protection can be disabled in secure mode. geändert am 03.11.2015 von DO MWS3_e Page 21 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 22 CAUTION: With RS485 after the ! or ? always the device address must be inserted! Other ways the command won't be accepted! (Standard@ = 1) geändert am 03.11.2015 von DO MWS3e.p65 Page 22 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web:...
  • Page 23: Querying The Microprocessor

    Only the info about the sensor 2 (temperature) will be sent..and so on. geändert am 03.11.2015 von DO MWS3_e Page 23 REINHARDT System- und Messelectronic GmbH Bergstr. 33 86911 Diessen-Obermühlhausen Postfach 12 41 D-86908 Diessen Tel. 08196 - 934100...
  • Page 24: Order Of The Mws 3 Sensors

    The number of sensors and the identifiers in the data string depend on the kind of sensor you ordered. geändert am 03.11.2015 von DO MWS3e.p65 Page 24 REINHARDT System- und Messelectronic GmbH Fax: 08196/7005 and 1414 email: wetter@reinhardt-testsystem.de Web: http://www.reinhardt-wetterstationen.de...
  • Page 25: Exchange Connectors

    5way connector (heating / GPS) : 99-0095-102-05 7way connector (data and power-supply) : 99-0475-102-07 8way connector (additional sensors) : 99-0479-102-08 Of course, you can order the connectors also from REINHARDT. I&OE / Specifications subject to change without prior notice ! 11/15 geändert am 03.11.2015 von DO...

Table of Contents