Anton IAQ 8494 Quick Start Manual page 2

Advertisement

Setup
To enter the setup mode (Fig. 3) press and hold button 1
for more than a second.
From here use buttons 2 (UP) and 4 (DOWN) to cycle
through the menu screens and button 6 to access the
selected menu screen (Fig. 4).
Buttons 2 and 4 can then be used to alter the alarm
threshold on menu P 1.1 and the temperature scale on
menu P 3.1 (Fig. 4).
Use button 6 to save the current setting and return to the
main menu screen (Fig. 3).
Press button 3 at any time to exit the setup menu.
 
Fresh Air Correction & Calibration
CO
Fresh Air Correction
2
It is strongly suggested that the unit be corrected in a
sunny, outdoor environment that is well ventilated. Do
not correct the unit in places crowded with people or
close to areas with high CO
ventilating outlets or fireplaces.
To correct the unit for CO
calibration site and press and hold buttons 2 and 3
simultaneously. The unit will flash continually for about
5 minutes, then return to normal operation.
To abort correction at any time, simply turn the meter
off.
CAUTION: The meter is corrected at ambient air of
around 400ppm. Do not correct the meter in an
environment with an unknown CO
Doing this could lead to inaccurate measurements.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
concentration such as
2
, place the meter in the
2
concentration.
2
Specification
CO
2
Range of 0 -9999
(maximum alarm threshold 9900
Resolution of 2
Accuracy ± 75
• Temperature
Range of -10 º to 60 ºC (14 -140 ºF)
Resolution of 0.1 ºC (0.1 ºF)
Accuracy ± 0.6 ºC
• Warm Up
30 seconds
• Operating Ranges
From 0~50ºC, 0 ~ 95% RH (avoid
condensation)
• Storage
From -20 º ~ 60 ºC, 0 ~ 99% RH (avoid
condensation)
• Power
4 pcs AA batteries, DC Adaptor
• Battery Life
10 hours (Alkaline)
• Warranty Period
3 years (anticipated sensor life 15 years)
Troubleshooting
• Fails to power up
Press button 1 for more than 0.3 seconds
and try again. Check whether batteries are
in good contact and correct polarity is
observed.
• Fixed readings
Check whether data hold function was
activated.
• Slow response
Check whether the air flow channels on the
rear are blocked.
• Error messages
E01: CO
sensor damaged
2
E02:The value is under range
E03:The value is over range
E04:The original data error results in this
error
E07: Voltage to measure CO
batteries or use an adaptor
E17: Retry CO
E31:   T emperature   s ensor   d amaged  
 
 
ppm
)
ppm
ppm
±5%
ppm
. Replace
2
calibration
2