User Manual for PH Warming Cabinets Beverage-Air WELCOME Congratulations on your purchase of Beverage-Air food Additionally, Beverage-Air food service equipment has service equipment. Every employee welcomes you to the one of the best warranties in the food service industry, family of satisfied Beverage-Air customers.
User Manual for PH Warming Cabinets Beverage-Air SAFETY This appliance has been designed with your safety in mind. It has many features to keep you from being harmed. However, safe operation and maintenance are your responsibilities. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
User Manual for PH Warming Cabinets Beverage-Air SAFETY CAUTION: If it is necessary to move the Cabinet after removal from the skid, remove all CAUTION doors and carefully push the unit at a point of no more than 36” from the bottom to avoid damage.
User Manual for PH Warming Cabinets Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial The manufacturer has designed and produced this application. That includes bars and restaurants. machine with the finest in materials. The manufacturer...
User Manual for PH Warming Cabinets Beverage-Air CLEARANCE AND PLACEMENT 0" LEFT/RIGHT 10" TOP MINIMUM MINIMUM CLEARANCE CLEARANCE 0" REAR MINIMUM CLEARANCE 0" BOTTOM MINIMUM CLEARANCE Placement Consider the following when selecting a location for your Cabinet: Clearance: • 10 in. at the top •...
User Manual for PH Warming Cabinets Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim.
User Manual for PH Warming Cabinets Beverage-Air UNIT SET-UP FOR ROLL IN UNITS Important: The floor where the new roll-in/roll-thru cabinet is to be permanently located must be level, flat surface prior to installation. Failure to properly level the install your equipment can void equipment warranty.
User Manual for PH Warming Cabinets Beverage-Air SHELF INSTALLATION 1. Determine the proper location for the shelf clips. 6. Place shelves so that the retaining tab on the clip The reference numbers on the pilaster can serve as a captures the shelf as shown.
User Manual for PH Warming Cabinets Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to the machine to confirm the voltage and per the dataplate its own dedicated power supply. Check the dataplate on use the correct fuses or circuit breakers.
User Manual for PH Warming Cabinets Beverage-Air PREHEATING & RECOMMENDED FOOD STORAGE PERIODS Food should not be placed in a cold warming cabinet. To Some food, such as breaded meats, fish, etc., when kept at preheat the warming cabinet, turn it on one (1) hour before proper temperature, requires less degree of moisture in the it will be needed.
User Manual for PH Warming Cabinets Beverage-Air USING THE UNIT Operation is simple, just keep it connected to the correct If equipped with glass doors, holding the SC button in will power supply and the warming cabinet will maintain the turn the cabinet light on or off.
User Manual for PH Warming Cabinets Beverage-Air ELECTRONIC CONTROLLER PARAMETER CHANGES Note: Key pad has a 3 second lock feature. Set key must be pressed for 3 seconds and released before keys will become active. Key pad will beep when unlocked and normal key pad operations performed.
User Manual for PH Warming Cabinets Beverage-Air SETTING THE REAL TIME CLOCK To set the real time clock, press and release the set button to enter the machine status menu. “Set will appear on the menu. Use the up and down button to scroll to the real time clock menu folder. “Rtc” will appear on the display.
User Manual for PH Warming Cabinets Beverage-Air ALARM CODES Code Description Relay Reset Parameters involved to Enable alarm Probe Pb1 failure Active Automatic Ont, Oft Probe Pb2 failure Active Automatic Ont, Oft Probe Pb3 failure Active Automatic Ont, Oft Probe Pb4 failure...
User Manual for PH Warming Cabinets Beverage-Air SEQUENCE OF OPERATIONS The cooler operates based on the air temperature measured by the probe located at the return air. Operation Controller Action Operation Controller Action Heating Elements Elements turn on The element Contact is...
Page 19
User Manual for PH Warming Cabinets Beverage-Air CONTROLLER Relay/Probe Description Terminal Out 1 Heating Elements 10,11 Out 2 Circulating fan 4, 5 Out 3 not used 7, 9 Out 4 Light (or alarm relay if electronic lock) 13, 14 PB1 –...
User Manual for PH Warming Cabinets Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Gaskets Routine maintenance Daily wipe down Daily inspection, check Annually that hinges are tight to Weekly interior the cabinet. Daily Exterior Cleaning It is much easier to clean on a regular basis than to have 3.
User Manual for PH Warming Cabinets Beverage-Air METHODS FOR CLEANING STAINLESS STEEL Cleaning Needed Cleaning Agent Method of Application Affect on Finish Satisfactory for use on all Areal 20, Lac-O-Nu, Lumin Wash Rub with cloth as directed finishes. Smears and fingerprints O’Cedar Cream Polish, Stainless...
User Manual for PH Warming Cabinets Beverage-Air HELP PROBLEM POSSIBLE CAUSE REMEDY Cabinet not operating Fuse blown or circuit breaker tripped Replace fuse or reset circuit breaker Power cord unplugged Plug in power cord to designated receptacle. Cabinet cannot share same outlet with other equipment.
User Manual for PH Warming Cabinets Beverage-Air HELP CONTINUED Product load burning Product load is too close to heating Rearrange product load so that it is not too close or boiling element to heating element(s). Controller setpoint is too high Adjust controller setpoint to a lower setting.
(63) months from the date of normal service rate time, for service performed during shipment from Beverage-Air, provided upon receipt of the normal working hours. Any service requested outside of compressor, manufacturer examination shows the sealed a servicer's normal working hours will be covered under compressor to be defective.
1 year parts & labor from the date of original installation. LIMITATION OF LIABILITY: Beverage-Air Corporation or their affiliates shall not be liable for any indirect, incidental, special or consequential damages, or losses of a commercial nature arising out of malfunction equipment or its parts components thereof, as a result of defects in material or workmanship.
Page 27
User Manual for PH Warming Cabinets Beverage-Air Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below. Cabinet Model Number: _____________________________________________ Date Of Installation: _________________ Cabinet Serial Number: _____________________________________________ Location Of Product Business Name: ____________________________________________________...