Summary of Contents for fluidra Certikin iSAVER+ DVSD03

  • Page 1 iSAVER+ Frequency Inverter for Swimming Pool Pumps DVSD03, DVSD04 IMPORTANT: READ CAREFULLY BEFORE USE. KEEP FOR FUTURE REFERENCE. Notice to Installer: This document contains important information about the installation, operation and safe use of this product – this information must be read before the installation and start-up of this product.
  • Page 2 Table of contents Content: Page No: Product conformity information Safety notices About the product List of supplied components Installation Settings & operation Maintenance Troubleshooting / protection & error codes Product conformity information This product complies with: • Low Voltage Directive (LVD) 2014/35/EU •...
  • Page 3 About the product The iSAVER+ swimming pool pump frequency inverter is designed to allow the user to control and vary the operational speed of the swimming pool pump in order to gain energy and cost saving efficiencies. The product benefits from multiple time and speed settings, which can be used manually or automated through timers. The easy to read display shows current operational settings and also provides power usage information for the setting in use.
  • Page 4 Technical data DVSD03 DVSD04 Input Power 1 phase AC Input Voltage 220-240V Input Frequency 50Hz Output Power Max 1. 1 kW Max 2.2kW Output Voltage 1ph, 0-240V Phase Type Single phase Max. Current Max 6A Max. 12A Speed Range 1200-2900rpm Cooling Ventilation Ventilation + Fan...
  • Page 5 Locating the device The choice of location for the device must meet the following condition: • Indoors • Ambient temperature of -10 to +40°C • Less than 1000m above sea level • Out of direct sunlight • Good ventilation (see below) For efficient cooling, ensure the unit is installed with a minimum clearance around it of 40cm above and below and 25cm at either side, as per Fig 2.
  • Page 6 Settings & operation CAUTION Do not touch the heat sink whilst the device is operating, or until 30 minute after the device has been switched off. It is normal for the heat sink to get hot during standard operation. Display control panel contents Power consumption Current time Speed in rpm...
  • Page 7 Initial operation When first powered up, will illuminate. Hold for 3 seconds in order to unlock the screen. Press to start the inverter. Upon starting, the pump will run at maximum speed of 2900rpm for one minute in order to ensure priming. This can be increased to up to 10 minutes if required –...
  • Page 8 External control External control can be enabled via the contact shown in Fig. 5 below. However, even if the device is working via an external controller, pressing can stop the device. For example – to enable external speed control via digital input, connect one of the digits from Di2/3/4 to COM NOTICE Do not apply voltage to these input contacts.
  • Page 9 Troubleshooting / protection & error codes The device may show error codes in certain circumstances – these codes could signify a fault, or may be an alert to protect the device form damage. Code Description Analysis / Action E001 Abnormal input voltage No fault –...
  • Page 10 Notes:...