IMPORTANT Questions regarding the use, care, or suitability of this equipment for your application? Contact SAFEWAZE™. IMPORTANT Record initial usage of product on Page 2, and Page 10. Competent Person inspections are required to be documented in the Inspection Log Table on Page 10.
INSTALLATION AND USE ..............8-9 INSPECTION ..................9-10 SAFETY INFORMATION ............... 10 LABELS ....................11 User Information Date of First Use: Serial#: Trainer: User: Do not throw away these instructions! Read and understand these instructions before using equipment! Page 2 V1.0 2018 Copyright SAFEWAZE™...
This manual and any other instructional material must be available to the user of the equipment. The user must understand how to safely and effectively use the FS-EX325 / FS-EX326, and all fall protection equipment used in conjuction with the FS-EX325 / FS-EX326.
Non- compatible connectors may unintentionally disengage (see Figure 3). Connectors must be compatible in size, shape, and strength. Self-locking snap hooks and carabiners are required by ANSI Z359 and OSHA guidelines. Contact SAFEWAZE™ if you have any questions about compatibility.
Ensure all connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all connectors are fully closed and locked. SAFEWAZE™ connectors (snap hooks and carabiners) are designed to be used only as specified in each product’s user’s instructions. See figure 4 for examples of inappropriate connections. Do not connect snap hooks and carabiners: •...
SRL. The structure to which the FS-EX325 / FS-EX326 is attached must withstand loads of at least 1,000 lbs. No free fall is allowed. For Work Positioning applications the FS-EX325 / FS-EX326 allows a worker to to be supported and work freely with both hands.
Wood Installation requires (40) #14-10 2” screws for wood decking To install, place FS-EX325 / FS-EX26 Anchor Post in desired installation location, and install ALL fasteners until snug to wood decking (ALL wood fastener installation holes MUST be used). User must ensure that ALL fasteners are fully embedded into wood decking.
Concrete Installation requires (8) 1/2” Hilti HIT-Z Rods or equivalent, with minimum 3-1/2” embedment To install, place FS-EX325 / FS-EX326 Anchor Post in desired installation location. Installation site must be a minimum 8” from all edges. Install ALL fasteners until snug and ensure FS-EX325 is fully secured to concrete substrate. (ALL concrete fastener installation holes MUST be used).
Fall protection systems must be designed in a manner compliant with all federal, state, and safety regulations. Forces applied to anchors must be calculated by a Competent Person. Page 10 V1.0 2018 Copyright SAFEWAZE™...