Hallmark MA0345X-9 Manual

Hallmark MA0345X-9 Manual

Shallow well jet

Advertisement

Safety
Important Safety Instructions
SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation, operation, and maintenance of the product.
Save this manual for future reference.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential
for personal injury!
indicates a hazard which, if not avoided, will
result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE addresses practices not related to personal injury.
Carefully read and follow all safety instructions in this
manual and on pump .
Keep safety labels in good condition.
Replace missing or damaged safety labels.
WARNING
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect power
before working on pump,
motor or tank.
Dual voltage motor is preset to 230V. If your power is 115V, you must pull the
red voltage switch on the back of the conduit box to 115V!
HALLMARK INDUSTRIES INC
624 Estes Ave, Schaumburg, IL 60193, USA
Wire motor for correct
voltage . See "Electrical"
section of this manual
and motor nameplate .
Ground motor before
connecting to power
supply .
Meet National Electrical
Code, Canadian
Electrical Code, and
local codes for all
wiring .
Follow wiring
instructions in this
manual when
connecting motor to
power lines .
WARNING
Shallow Well Jet Pumps
Electrical Safety
Capacitor voltage may be hazardous .
To discharge motor capacitor, hold insulated handle
screwdriver BY THE HANDLE and short capacitor
terminals together. Do not touch metal screwdriver blade
or capacitor terminals. If in doubt, consult a qualified
electrician.
General Safety
Do not touch an operating motor. Modern
motors are designed to operate at high temperatures. To
avoid burns when servicing pump, allow it to cool for
20 minutes after shut-down before handling.
Do not allow pump or any system component to freeze.
To do so will void warranty.
Pump water only with this pump.
Periodically inspect pump and system components.
Wear safety glasses at all times when working on pumps.
Keep work area clean, uncluttered and properly lighted;
store properly all unused tools and equipment.
Keep visitors at a safe distance from the work areas.
Pump body may explode if used as a
booster pump unless relief valve capable of passing full
pump flow at 75 psi is installed.
Must reset the voltage!
www.hallmarkind.com
1
WARNING
Hazardous pressure!
Install pressure relief
valve in discharge pipe.
Release all pressure on
system before working on
any component.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MA0345X-9 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hallmark MA0345X-9

  • Page 1 Dual voltage motor is preset to 230V. If your power is 115V, you must pull the red voltage switch on the back of the conduit box to 115V! HALLMARK INDUSTRIES INC Shallow Well Jet Pumps 624 Estes Ave, Schaumburg, IL 60193, USA...
  • Page 2: Installation

    Install a sanitary well seal. 5–10' Figure 2: Cased Well Installation HALLMARK INDUSTRIES INC Shallow Well Jet Pumps 624 Estes Ave, Schaumburg, IL 60193, USA www.hallmarkind.com...
  • Page 3 5.2/2.6 22 lbs MA0345X-8 14 gpm 135 (ft) 33 (ft) 115/230 6.5/3.3 38 lbs MA0345X-9 24 gpm 151 (ft) 33 (ft) 115/230 10.4/5.2 40 lbs HALLMARK INDUSTRIES INC Shallow Well Jet Pumps 624 Estes Ave, Schaumburg, IL 60193, USA www.hallmarkind.com...
  • Page 4: Discharge Pipe And Pressure Tank Connections

    From E. I. DuPont de Demours and Company Corporation, Delaware Well Figure 5: Standard Tank Connections HALLMARK INDUSTRIES INC Shallow Well Jet Pumps 624 Estes Ave, Schaumburg, IL 60193, USA www.hallmarkind.com...
  • Page 5: Wiring Connections

    14.8/7.4 20/15 12/14 (3/2) 8/14 (8.4/2) 6/14 (14/2) 6/12 (4/3) 4/10 (21/5.5) 115/230 19.2/9.6 25/15 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5) HALLMARK INDUSTRIES INC Shallow Well Jet Pumps 624 Estes Ave, Schaumburg, IL 60193, USA www.hallmarkind.com...
  • Page 6: Preparing To Start The Pump

    A small amount of water left in the pump will not harm it if it freezes. NOTE: Our jet pumps are self priming. However, user needs to prime the pump in the first use! HALLMARK INDUSTRIES INC Shallow Well Jet Pumps 624 Estes Ave, Schaumburg, IL 60193, USA www.hallmarkind.com...
  • Page 7 Parts and repair (For reference only. We do not stock spare parts!) Stainless steel jet pump Cast iron jet pump HALLMARK INDUSTRIES INC Shallow Well Jet Pumps 624 Estes Ave, Schaumburg, IL 60193, USA www.hallmarkind.com...
  • Page 8: Troubleshooting

    Consult factory about installing a sleeve in the well. Intermittent over-pumping of well. (Water Lower foot valve if possible, otherwise restrict pump discharge. drawn down below foot valve.) HALLMARK INDUSTRIES INC Shallow Well Jet Pumps 624 Estes Ave, Schaumburg, IL 60193, USA www.hallmarkind.com...
  • Page 9 STEP 2. Open the pressure switch cover, flip the rubber grummets - cone shape is now outside. Figure 2 STEP 3. Connect the motor’s cable wires to the pressure switch (Figure 3). The ground wire (with a ground tag, yellow/green) must be wired to one of the ground screws. Figure 3 HALLMARK INDUSTRIES INC...
  • Page 10 Pressure setting for 3/4HP model may not exceed 30/50 psi setting! Pressure setting for 1 HP model may not exceed 40/60 psi setting! STEP 6. Put the pressure switch cover back on. Tighten the screw by hand. Figure 5 HALLMARK INDUSTRIES INC...