USBREC-PTA (REV. D)
ENGLISH
IN U.S.A.: Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293
TR7740 — USB RECEPTACLE
MUST BE INSTALLED AND USED IN ACCORDANCE WITH ELECTRICAL CODES.
WARNING:
Turn circuit breaker OFF or remove fuse(s) and test that power is off.
CAUTION:
• Use only copper wire with this device. Do not use with aluminum wire. When installing these devices, a
neutral wire is required for the outlet.
• Only a single branch circuit should supply this device.
• Use only appropriate Class 2 connectors with interconnecting cables.
• The Class 2 output connections are not intended for supporting products or appliances.
• Any output cable connected to the Class 2 outputs is to be routed away from the receptacle outlet slots
or an inserted attachment plug blades into receptacle outlet.
DESCRIPTION:
The USB Receptacle is a device that provides AC power in one receptacle and 5V - 0.7A DC on the USB
connector for purposes of charging Portable/Mobile devices. The USB ports are for charging purposes only
and not data transfer.
When equipment is being charged, the green LED on the face of the device will be ON and when the
equipment is fully charged the green LED will turn OFF.
TO INSTALL:
1. Suitable for installation in outlet box measuring a minimum 3" x 2" x 2-1/2" deep and wired in accordance with NEC article 314 box fill
requirements.
2. Verify Power is OFF before installation
3. Strip wires to the length of strip gauge on the back of the receptacle.
4. This device must be properly grounded for shock protection. Per NEC 250.146(B), an automatic grounding clip will establish grounding contact
between receptacle and grounded metallic box without a jumper. For non-metallic boxes connect green or bare grounding wire to green colored
terminal screw.
5. Connect hot line (black) wire to black colored screw and neutral wire (white) to silver colored screw. Wires can be connected using one of the
following methods:
To Use Wire Clamps: Insert stripped wire between the wire clamp and terminal and tighten the screw to 14 inch – lbs. Wire clamps accept up
to #12 AWG copper wire.
To Use Terminal Screws: Wrap stripped wires ¾ turn clockwise under heads of screws and tighten the screws to 14 inch – lbs. Terminal
screws accept up to #12 AWG copper wire.
6. Attach wallplate and then restore power.
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1: This device may not cause harmful interference, and
2: This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules as an
unintended radiator. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
FRANÇAIS
IN CANADA: Cooper Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8 • 800-267-1042
PRISE USB — TR7740
DOIT ÊTRE INSTALLÉ ET UTILISÉ SELON LES RÈGLEMENTS ÉLECTRIQUES
MISE EN GARDE :
Coupez le courant au disjoncteur ou enlevez le ou les fusibles et contrôlez que le courant est coupé.
ATTENTION :
• Utilisez uniquement du fil de cuivre sur cet appareil. N'utilisez pas de fil d'aluminium. Pour installer ces appareils, il faut disposer d'un fil de
neutre pour la prise.
• Il ne faut alimenter cet appareil que par un seul circuit en dérivation.
• Utilisez uniquement des connecteurs de classe 2 sur les câbles d'interconnexion.
• Les connexions de sortie de classe 2 ne sont pas conçues pour supporter des produits ou des appareils ménagers.
• Tout câble de sortie raccordé aux sorties de classe 2 doit être éloigné des fentes de la prise ou des fiches d'un accessoire inséré dans la prise.
DESCRIPTION :
La prise USB est un appareil qui fournit une alimentation en C.A. sur une des prises et 5 V C.C. sur le connecteur USB afin de charger des
appareils portatifs ou mobiles. Les connecteurs USB servent uniquement à charger, pas au transfert de données.
Quand un équipement est en train d'être chargé, la diode verte située sur l'avant de l'appareil s'allume et elle s'éteint quand l'équipement est
rechargé à fond.
Green Screw
Vis vert
Tornillo verde
Black Screw
Neutral
Vis Noir
Neutre
Tornillo negro
Neutro
Silver Screw
Vis en argent
Tornillo de plata
Line (Hot)/Ligne (Fase)/Linea (Phase)