Specifications - Wolf Dual Fuel Range Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

Specifications

Installation Requirements
IMPORTANT NOTE: When installing against a combustible
surface, a minimum 10"
(254)
fuel range with charbroiler or griddle and all 48" and 60"
models. Follow all minimum clearances to combustible
surfaces shown in the illustration on page 7.
riser is required for a 36" dual
Electrical Requirements
Installation must comply with all applicable electrical
codes.
Locate the electrical supply flush with the wall or floor
and within the shaded area shown in the illustration on
page 7. A separate circuit servicing only this appliance is
required.
If a power supply cord is used, the cord must be desig-
nated for use with ranges and rated for 240 V, 30 or 50
amps (refer to the chart below), and must include 3 or 4
conductors. A 4-conductor cord is required for installa-
tions where grounding through the neutral is prohibited.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS—SINGLE OVEN
Electrical Supply
Service
Total Amps
Max Connected Load
ELECTRICAL REQUIREMENTS—DOUBLE OVEN
Electrical Supply
Service
Total Amps
Max Connected Load
RATING PLATE
Rating plate location
grounded, 240/208 VAC, 60 Hz
30 amp dedicated circuit
21
5.2 kW
grounded, 240/208 VAC, 60 Hz
50 amp dedicated circuit
42.5
10.2 kW
wolfappliance.com | 5