Advertisement

Quick Links

InKjel P
Digestion Unit
User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InKjel P and is the answer not in the manual?

Questions and answers

Summary of Contents for BEHR InKjel P

  • Page 1 InKjel P Digestion Unit User‘s Manual...
  • Page 2 Please read this operating manual carefully before starting use of your new InKjel P digestion unit! The manual introduces you to the use of the apparatus with clear and simple guidance. For reasons of safety in use of the system, please follow all safety warnings carefully. These are designated in the...
  • Page 3: Safety Advice

    Safety Advice Danger of burns! The digestion tubes and the heating slot get hot! Never touch the hot glasses, the sample rack, the heating slot or the exhaust tubes with the bare hands. Danger of electric shock! Always install all cables in such a way that they cannot come into contact with the hot zone of the heating cavity; they could otherwise smoulder through! Always ensure that no liquids can come into contact with cable connections or the interior of device! Always withdraw the mains plug before opening the unit! Repairs on electrical, electronic and mechanical modules of this appli‑ ance may be performed only by authorized specialist staff. Danger: glass can break and cause injury! In working with glass components, observe all appro‑ priate safety precautions. Be careful in working with corrosive substances! Follow the safety guidance in the pertinent Safety Data Sheets. Hazard from toxic gases! During the Kjeldahl digestion, vapours of sulfuric acid (and other toxic gases) are set free. They could harm your health and damage the apparatus and your lab equipment. When performing digesting operations that can set free toxic or corrosive vapours, always use a scrubber system! Place the digester and the scrubber in a fume cupboard. Never operate the digestion unit in wet, humid or explosion‑endangered areas! Maximum air humidity = 80% Maximum temperature = 40° C...
  • Page 4: Table Of Contents

    Switching the Device On............................9 Using the InKjel P ..............................9 The operating unit ................................9 The Start menu................................10 Configuring the InKjel P to meet your needs ....................... 10 Write a heating program ............................... 12 Processing samples ..............................13 Maintenance ................................16 Cleaning the Exhaust Collector ............................
  • Page 5: Scope Of Supply

    InKjel P Scope of supply Correct use of the InKjel P The behr InKjel P digestion unit is used for heating Please check the contents of the pack for completeness samples in the appropriate digestion tubes. It is used, and freedom from damage immediately upon receipt.
  • Page 6: Overview Of The Behr Inkjel P

    InKjel P Overview of the behr InKjel P Exhaust collector Drip pan Suction hose Mounting rack Sample rack Heating slot with IR radiators InKjel base unit Control unit Mains switch – 6 –...
  • Page 7: Setting Up The Inkjel P

    InKjel P Setting Up the InKjel P Danger of electric shock! Always install all cables in such a way that they cannot come into contact with the hot zone of the heating cavity; they could oth‑ erwise smoulder through! Always ensure that no liquids can come into contact with cable connections or the interior of device! Always withdraw the mains plug before opening the unit! Repairs on electrical, electronic and mechanical modules of this appliance may be performed only by authorized specialist staff. Fixing the mounting rack Place the base unit on a level horizontal surface in  such a way tha the mounting brackets point to the rear.
  • Page 8: Connecting To Mains Power

    InKjel P. Make sure the mains switch on the front of the device  is in 0 position. Plug the InKjel P power cable into a grounded mains  socket. – 8 –...
  • Page 9: Switching The Device On

    Switch the mains switch on the front of the appliance to the „I“ position. The mains switch of the behr InKjel P performs two functions. It is used, on the one hand, to switch the unit on and off. There is, in addition, a fuse inte- grated into the switch.
  • Page 10: The Start Menu

    InKjel P The Start menu Configuring the InKjel P to meet your needs You can, in fact, use your InKjel P for analyses right 14:05 now. You should, however, take a couple of minutes to perform one or two settings.
  • Page 11 Autostart The following possibilities can be selected Three languages are permanently programmed in the here: InKjel P : D (German), GB (English), F (French). A fourth Off - the InKjel P will only start to heat language can be added as an option.
  • Page 12: Write A Heating Program

    Write a heating program You will now see for every program step a page, on which you can enter the settings for this step. The InKjel P can be used to write up to 25 different heating programs. Program 01/01 A program can have up to 20 program steps.
  • Page 13: Processing Samples

    Processing samples Which program for which kind of samples? When digesting solid samples, you want to get the Switch the InKjel P on (mains switch on the rear  samples boiling soon. When this is achieved, they panel of the unit).
  • Page 14 The number of the program step which is currently being run is shown at the bottom. The InKjel P does not react to any operation of the operating button while a program is running. The program cannot be interrupted by actuating the oper- Prog 01/01 ==>>...
  • Page 15 InKjel P Finishing digestion and removal of samples Danger of burns! The inner zone of the heating block and the sample vessels get hot! Never touch the hot glasses or the area of the heating block around the mounting holes with the bare hands. Always remove the samples from the heating block using the sample rack and allow them to cool as described here. Caution: there are acid condensates in the exhaust collector. They can burn you and stain the metal parts of your device. Wash your hands with water after contact with the condensate. Insert the drip tray after inserting the exhaust collector in the mounting rack. Grasp the sample rack using the two red handles.  Lift the rack carefully, together with the exhaust col- ...
  • Page 16: Maintenance

    The housing surface of the InKjel P is low-care and largely insensitive to acids. Never use abrasive cleaning agents for cleaning of the front or rear panels. In the drip pan rests of sulfuric acid will collect that have condensed in the exhaust collector.
  • Page 17: Changing The Exhaust Collector Tube

    InKjel P Changing the Exhaust Collector Tube The exhaust collector of the InKjel P consists of a glass collector tube that conducts the exhaust gas from the sample vessels to the suction hose, and the steel hous- ing. If the glassware part should get broken you need not replace the exchaust collector as a whole but just insert a new collector tube.
  • Page 18 InKjel P Lay the other two silicone buffers on top of the collec-  tor tube, in the places where the pipe clips are to be screwed on. Insert the pipe clips on top of the new collector tube ...
  • Page 19: Keep Your Device Working Reliably As Long As Possible

    InKjel P Keep your Device Working Reliably as Long as Possible The Kjeldahl digestion produces a highly aggres- sive mixture of sulfuric acid vapour, sulfur dioxide and organic vapours. This gas mixture will, with time, cor- rode even stainless steel surfaces and make them look shabby.
  • Page 20: Avoid Bumping

    Make sure to treat the blank in the same way as the samples. If you have an infrared digestion device (e. g. behr InKjel) too, the easiest way to digest high-protein samples will be the infrared digestion. In an infrared digestion, the samples reach digestion temperature very quickly so the foam will collapse soon.
  • Page 21: Spare Parts

    InKjel P Spare Parts Description Art.-Nr. Round-bottom digestion vessel 250 ml, for sample rack EG 12 B 0021 7959 Round-bottom digestion vessel 500 ml, for sample racks EG 6, EG 4/500 B 0021 8195 Round-bottom digestion vessel 750 ml, for sample rack EG 4/750...
  • Page 22: Technical Data

    InKjel P Technical Data Nominal voltage 230 V~, 50 Hz Power 1 500 W Dimensions (W x H x D) approx. 540 x 750 x 440 mm Weight approx. 20 kg Time range 0 ... 199 minutes, in 1-min steps Heat output range 0 ...