  • Page 2: Important Notes

    However should maintenance be required it should be carried out by a competent person with reference to these instructions. Before any work is carried out the root cause of the problem must be identified. Lakes Bathrooms service engineers are available if necessary to consult / carry out remedial work. Call Lakes Bathrooms HELPLINE.
  • Page 3 MODELS : order with respective Coastline product, OR add to existing installation to make the following styles..refer to, & use in conjunction with Coastline Walk In instructions. Cannes (or Side Panel) Marseilles Riviera* (may be single or twin bypass) Unit Comprises Cartons...
  • Page 4 Supplied : Bypass assembly comprising Hinge 2x (handed pair) (LK827-002/003) Gasket 2x (glass corners) (LK827-007) Bearing sleeve (LK827-006) 4mm x 30 long pan head pozidriv self tapping screw (F006) Hinge seal Hinge boss (S059-1971) (LK827-004) Hinge alum #1 (8025-1969) Bypass sub assy (glass + hinge alum #2) Tools Required Spirit level (with vertical ‘bubble’)
  • Page 5 Lakes Coastline hinge bypass is fully reversible so can be fitted to LH or RH products. Installation may be carried out at same time as parent unit, OR at a later date. If already fitted, carefully cut silicone & remove the corner trim from bottom glass corner. Thoroughly clean &...
  • Page 6 Align & push bypass assy onto glass edge firmly until aluminium is fully seated onto glass edge over entire height. CHECK that alum #1 is completely straight using a long (1.5m) straight edge or spirit level. If bow is present, the ‘high’ areas should be pressed further by hand, or using a block of wood for protection, may be ’knocked on’...
  • Page 7 ONLY. Water / moisture appearing outside this area (ie at floor level or under shower tray) is normally due to incorrect tray / wall sealing. Lakes Bathrooms Lakes Bathrooms Ltd Service : Northern Ireland Alexandra Way Ian A Kernohan...