Sealey BT2001 Instructions page 2

Digital battery tester 6-12v

Advertisement

3.2
DISPLAY GENERAL
by pressing the  (UP) and  (DOWN) buttons
the display will cycle through the options. Press ENTER
button when the option you require is displayed.
Battery Type:
Regular liquid.
AGm Flat Plate.
AGm spiral.
VRlA/Gel.
3.3
BATTERY TEST
3.3.1
With battery test screen displayed
press EnTER.
3.3.2
use the  (UP) and  (DOWN) buttons
to select the battery type:
Regular liquid, AGm Flat Plate, AGm
spiral or VRlA/Gel.
Press EnTER to confirm choice.
3.3.3
use the  (UP) and  (DOWN)
buttons to select the battery rating: sAE,
En, IEc, DIn or JIs.
Press EnTER to confirm.
3.3.4
use the  (UP) and  (DOWN)
buttons to input the battery capacity of
ccA:
sAE:
40 - 2000
En:
40 - 2100
IEc:
30 - 1500
DIn:
25 - 1300
JIs: by battery type
Press EnTER to begin test.
3.3.5
battery being tested for a few seconds.
3.3.6
Press  (UP) and  (DOWN) buttons
to select battery fully charged: Yes or No.
Press EnTER to confirm
3.3.7
When the test is complete, the lcD
shows the actual volts and ccA or Ah.
Press  (UP) and  (DOWN) buttons
to select: sOH (state of Health) or sOc
(state of charge).
One of the following results will be
displayed.
3.3.8
GOOD & PASS: battery is capable of
holding a charge.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
choice.
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk business Park,
bury st. Edmunds, suffolk,
IP32 7AR
Original Language Version
Fig.1
nOTE! The operator is asked if any accessories are left on as a possible
cause. If accessories are left on, the operator is instructed to charge and retest
the battery. If accessories are not left on, the operator is instructed to replace
the battery since the charging system is working and a good battery should have
accepted a charge.
01284 757500
01284 703534
use the  (UP) and  (DOWN)
buttons to select language or press
EnTER to commence battery test
use the  (UP) and  (DOWN)
buttons to return to battery test or press
EnTER to set language.
use the  (UP) and  (DOWN)
buttons to select language.
English, French, German, spanish,
Italian, Portuguese or Japanese.
Press EnTER to confirm choice and
return to battery test.