Summary of Contents for Trion Grease Viper Series
Page 1
Grease Viper Series READ AND SAVE THESE INSTRUCTIONS Electrostatic Precipitators Commercial & Industrial Applications T R I O N | w w w . t r i o n i a q . c o m ®...
I n s t a l l a t i o n , O p e r a t i o n , & S e r v i c e M a n u a l Electrostatic Precipitators for Commercial & Industrial Applications Grease Viper Custom Electronic Air Cleaner Table of Contents...
TRION Tridex Detergent is specially formulated ® • Inlet Plenum Section with Grease Baffle Impinger for use with TRION® electronic air cleaners. Use Prefilters of other cleaners and detergents, not specifically • Electrostatic Precipitator (ESP) with Integral approved by TRION , can cause possible failures ®...
Any additional access that may be such as cooking grease and petroleum based provided in the system, where there is access oils. TRION® strongly recommends a fire to high voltage, must be equipped with such suppression system be installed in the ductwork interlocks.
The length of the wash water supply line between the Grease Viper cabinet and the heated building should Adjoining Ductwork (not supplied by TRION be kept to a minimum. Preferably the line would go ® The ductwork located on the air entering side of the...
I n s t a l l a t i o n , O p e r a t i o n , a n d S e r v i c e M a n u a l are shipped inside the cabinet. On large units, the cabinet, then re-install the ionizing-collecting cells and cells may be shipped in separate containers.
Unless otherwise specified, the water wash supply 9. Check Out for System Start-up should be hot (140°F recommended - WATER When the installation has been completed, assure HEATER NOT SUPPLIED BY TRION ) at the volume that the equipment is ready for start-up by checking ®...
Install cells into 1. Inspect the inside of the adjoining ductwork and the cabinet in accordance with the directional arrows TRION cabinet to be sure it is clean and free of ® w w w. t r i o n i a q . c o m...
Page 9
Allen head set facing the access side of the cabinet. screw located in the valve adjustment knob. When 3. Confirm that the drain lines from the TRION cabinet the correct adjustment has been made, remove the ®...
I n s t a l l a t i o n , O p e r a t i o n , & S e r v i c e M a n u a l Adjusting Clock Temporary Override Press and hold CLOCK and then press DAY key, HOUR Condition 1: When timer’s output status is ON, press key, MIN key respectively to adjust clock of timer to...
® is formulated specifically for electronic air cleaners. If approved should be checked for securement and substitutes are used, they must be approved by TRION tightened or reworked as required. ® w w w. t r i o n i a q . c o m...
I n s t a l l a t i o n , O p e r a t i o n , a n d S e r v i c e M a n u a l At the start of the cleaning process, electrical switches Ionizing-Collecting Cell(s) - Every 6 Months Handle cells with care to avoid damage to the that could be accidentally activated shall be locked...
Page 13
I n s t a l l a t i o n , O p e r a t i o n , a n d S e r v i c e M a n u a l 1. Disconnect both high voltage leads from their The electronic air cleaner is the unit within the system respective terminals on the power supply and that has the highest efficiency collection rating and is...
Goods, Seller warrants that installation. For specific recommendations, consult that Goods are free from defects in material and the TRION factory or nearest representative. workmanship, except for services which are warranted ®...