Ear syringe lever action for use in the removal of cerumen along the outer ear canal

Advertisement

Quick Links

NJ PHILLIPS EAR SYRINGE DISTRIBUTION NETWORK
NSW / ACT / VIC / WA / TAS
ALL STATES MEDICAL SUPPLIES
Contact: John Davies
Tel: 1300 520 510
Email: sales@allstatesmedical.com.au
MEDICAL AND SURGICAL REQUISITES PTY. LTD.
Contact: MEDI + Plus - Service Advisor
Richlands, Brisbane
Tel: (07) 3859 2900
Email: medical@medsurg.com.au
Atlas McNeil Healthcare
32 – 50 Weaver Street
Tel: 1300 741 085
Web: atlasmcneil.com.au
ESTEEM HEALTHCARE LTD
Contact: Mr. Brent Mitchell
PO Box 18-040, Glen Innes
Tel: 0800 427 968
NJ PHILLIPS PTY LTD
ABN 36 000 082 002
ADDRESS: LOCKED BAG 8, GOSFORD, NSW 2250 AUSTRALIA
TELEPHONE: +61 2 4340 2044
FAX: +61 2 4340 1991
EMAIL: njp1@njphillips.com.au
MADE IN AUSTRALIA
AS OUR POLICY IS ONE OF CONTINUOUS IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO ALTER THESE SPECIFICATIONS AT ANY TIME.
ALL PRODUCTS PRODUCED BY NJ PHILLIPS PTY LIMITED, ARE IDENTIFIED BY A UNIQUE BATCH NUMBER. THIS IDENTIFICATION NUMBER IS AFFIXED
TO THE PRODUCT TO ALLOW TRACEABILITY BY THE MANUFACTURER AND MUST NOT BE REMOVED IF PRODUCT INTEGRITY IS TO BE MAINTAINED.
AUSTRALIA
35 Ellen Street
Wollongong
NSW 2500
Fax: 1300 509 089
QLD
33 Fulcrum Street
QLD 4077
Fax: (07) 3859 2995
SA / NT
Unit 5
Edwardstown
SA 5039
Fax: 1300 365 408
NEW ZEALAND
or
24B Morrin Road
Tamaki
Auckland NZ
Fax: 0800 337 833
EAR SYRINGE LEVER ACTION
For use in the removal of cerumen along the outer ear canal.
EARDRUM
ASSEMBLING METAL TIP UNIT:
1. Loosen needle nut until reasonably loose.
2. Slide needle tip base into the lower slot of the needle
nut.
3. Screw the needle nut tightly back onto the main
threaded mount.
ASSEMBLING SILICONE TIP UNIT:
1.
The silicone tip MUST always be sterilised prior to
use.
2.
Remove the metal tip and needle nut.
3.
Push the silicone tip onto the main threaded mount.
Turn clockwise as you push to ensure it is fi rmly in
place.
Packs of 25 silicone tips are available from your
distributor – Order Code: SP1370B.
CLEANING OR STERILISATION:
The following items may be autoclaved:
Ear tips needle; needle nut; the entire lever action hand
piece – however it is important to apply a small drop of
NJ Phillips Lubricant to any moving part post autoclave
as good maintenance. To apply NJ Phillips Lubricant to
moving parts within the handle grip, carefully unscrew
counter clock wise.
PAS1043 | QL561-R24
CAUTION:
1. DO NOT insert the ear tip end into the
outer ear canal.
2. Take due care - rapid jets of water
directed at the tympanic membrane could
be harmful.
3. This device should only be used by a
health care professional familiar with ear
syringing techniques.
ARTG No: 145575
The rubber tip is designed to be autoclaved
at temperatures of up to 250 degrees
NOTE
celsius for up to 3.5 hours.
Make sure the thread is properly engaged
!
when reconnecting the handle grip. To
IMPORTANT
reconnect handle grip, gently pull lever trigger
until the handle grip cover slides up and over
the handle body and screw clock wise until
tight – DO NOT OVER TIGHTEN!
It is unnecessary, nor desirable, to dismantle any part of
the lever action unit for any purpose other than to lubricate
moving parts.
DO NOT autoclave the hose piece, rather
wash in a good quality Medical Equipment &
NOTE
Instrument detergent, then hang to drip dry.
LIQUID MEASURE DISPERSMENT SETTINGS:
1. To set liquid dispersment
adjust
the
circular
located at the bottom of the
handle. Turn the circular
nut clockwise or counter
clockwise to adjust the
CIRCULAR NUT
(ml) calibrations printed at
the top of the body post. Adults generally require 3-5 (ml)
setting. The dose is set from the bottom of the lever arm.
DOSE SETTING
BODY POST
2.
Prime instrument to ensure all air is removed prior to
use on the patient.
nut

Advertisement

loading

Summary of Contents for NJ PHILLIPS KIT-PAS1043

  • Page 1 AS OUR POLICY IS ONE OF CONTINUOUS IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO ALTER THESE SPECIFICATIONS AT ANY TIME. ALL PRODUCTS PRODUCED BY NJ PHILLIPS PTY LIMITED, ARE IDENTIFIED BY A UNIQUE BATCH NUMBER. THIS IDENTIFICATION NUMBER IS AFFIXED moving parts within the handle grip, carefully unscrew use on the patient.