Introduction .......................1 1 Design ..................................2 Extra functioning ..................................2 2 Versions ..................................3 Possebilities .......................5 1 Basic functioning ..................................6 Settings .......................7 1 Function Menu ..................................8 2 Function Overview ..................................8 Specifications .......................15 Appendix .......................17 Version 4.1.2 http://www.inepro.com...
Page 5
Due to continuous product improvements this manual is subject to change without notice. This document describes the technical and functional operation of the MicroTimer 2400. Greatest care has been taken drafting the information in this manual and it may be said that it is reliable. However, the producer is not liable for any shortcomings in the text or incompleteness of the information.
Automatic representation of the Running time counter is affected by pressing the Stop key during 3 seconds. The service counter generates a SR (service message) on the display MicroTimer 2400...
Versions De versies There is one type of MicroTimer® available as the functioning of the MicroTimer® mainly depends on the additional software modules and the settings...
The operator may choose either to allow the creation of a pause during the main time or not. If a pause is allowed, it can be created by pressing the Start/Pause key. The operator can also choose between interrupting and continuing the main time during the pause mode MicroTimer 2400...
E C O S module E M -01 y ou can set the main time from 1-255 1-255 12 (M ax. 255) minutes. If a v alue of more than 100 minutes is programmed the indication w ill be display ed N ote: intermittently in tw o parts; first display “1”, second display “00”. MicroTimer 2400...
Page 15
Function Overview Function F2, Prior time setting ECOS module EM-02) P r ior time setting. Befor e the main time is star ted, r elay 2 will be closed. P r ior Function T ime is the dur ation in minutes that r elay 2 is closed befor e the main time begins.
Page 16
T his blockage can be r aised by pr essing the inter nal or exter nal up Function key for 3 seconds. T o indicate the necessity of cleaning will appear inter mittently on the M icoT imer ® display. Setting Descr iption Default C lean function off C lean function on. MicroTimer 2400...
Page 17
Function Overview Function FA, Standard or external start mode Function Star t M ode T ype Setting Descr iption Default The M icoTimer can be started by pushing the Timer button or by generating a puls, w hich is longer as 200 msec, on the external connection (remote button print).
Page 18
Interrupting the activ e signal w ill put the M icoTimer in post-time (w hen enabled). The controls is depending on the setting in menu (remote button print input or coin mechanism input). This setting must be set on 0 for this dev ice. note: MicroTimer 2400...
Page 19
Function Overview Function P2, After start ECOS module EM-07) A fter star t; A t the end of a whole session it is possible to allow one extr a time of 3 0 seconds. T o obtain this time the down key has to be pr essed. T his setting Function pr ovides a solution for machines, which have to be connected for a shor t per iod of time after the pr ogr ammed time has expir ed, e.g.
Page 20
P ayment dur ing main time Setting Descr iption Default P ay ment during main time is disabled P ay ment during main time is enabled The maximum amount of coin pulses can be programmed in function note: MicroTimer 2400...
Page 22
M aximum r uptur ing capacity of the r elay: 16 ampere max. w ith cosine phi = 1 A dmissible r uptur ing capacity of the r elay: 16 ampere max. w ith cosine phi = 1 MicroTimer 2400...
Page 24
(P 1 A lso used for; Read out counter v alues (F B -F E ), M ain Dow n Button Time Reduction (P 7 ), A fter S tart (P 2 ), Reset (F B -F E MicroTimer 2400...
Page 25
The output signal depends on the settings in Functie P0 Connection diagram with external connections and a live output Use this diagram to connect one or two devices (A & B) that must be fed by the main 230V AC feed.
Page 26
Connection diagram with external connections and uncharged (neutral) output Use this diagram to connect one or two devices (A & B) that relays power to one of their outputs and must be electronically fed trough that other output of the device. MicroTimer 2400...
Page 27
4. Enable / disable the Start button 3. Enable / disable the Timer button 2. Enable / disable the Stop button 1. Enable / disable the Function Register Wiring diagram to control the MicroTimer® from a computer with INEPRO software.