Kingfisher PLUS+
Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PLUS+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingfisher PLUS+

  • Page 1 Kingfisher PLUS+ Installation Manual...
  • Page 2 Added ADP-08-M, ADP-29, RJC-ADP-30 and ADP-30 cables. 12/7/2007 Updated the RA Form. Added coaxial cable information. Added DO-5 wiring diagram. Kingfisher Series II is now called Kingfisher PLUS+. 17/4/2008 Removed revision history entries prior to 2004. RJC-ADP-26 is now used for a Maxon 3G modem (instead of a CDMA modem).
  • Page 3: Table Of Contents

    PSU-3: Economy AC Input Power Supply (for PC-1)............21 Solar Panel Installation ..................22 10. Level Probe Installation..................22 11. Antenna Installation..................23 11.1 Antenna Cable Selection And Installation ................24 11.2 How To Assemble Antenna Connectors................24 12. Return Of Goods ..................... 25 Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 4: Rtu Layout

    DI-5 module. The modules can be installed in any order if so desired (except a PC-1 must be installed in the leftmost slot of a BA-4 backplane since it has two sockets). Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher...
  • Page 5: Installing Modules

    I/O connector. The I/O connector is secured to the module using two fastening screws as shown below. I/O Connector Fastening Screw I/O Connector Fastening Screw Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 6: Backplane Setup

    (typically installed in the left slot). Note: a single supply can be used to power both backplanes using a BPC-0x power cable if the total current load of the supply is not exceeded. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 7: Enclosure Layout

    THIS WILL PREVENT DAMAGE TO THE RADIO IF IT TRANSMITS. All components of a Kingfisher PLUS+ RTU shall be installed inside of an enclosure providing safety and environmental protection. The enclosure shall be made from metal or other material with a flammability rating of V-0 or better in accordance with the requirements of the IEC 60950-1:2001 standard for a fire enclosure.
  • Page 8: Rack Mounting

    TEL-RAK-002 mounting bracket. One BA-6 or two BA-4/BA-40 backplanes can be attached to the TEL-RAK-002 using the surface mount brackets supplied with each backplane. The TEL-RAK-002 is supplied with eight M3 x 5 mm screws for attaching the backplane(s). 450 mm 222 mm 222 mm Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 9: Installing Cables And Adaptors

    RJ45 TO RJ45 PATCH CABLE Spread Spectrum Radio XTend-PKG or XStream-PKG from www.digi.com ADP-08M RJ45 RS232 RJ45 TO RJ45 PATCH CABLE TRIO D OR E SERIES RADIO RJ45 RJ45 TO RJ45 PATCH CABLE RS232 ADP-16 Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 10 RJ45 LINE-2 LINE-2 POWER RJC-ADP-30 WIRE. CONNECT TO RADIO POWER +12 V TRIO M SERIES ANALOG RADIO (eg. MR450) with NO MODEM FITTED PC-1 MC-1 RJ45 RJ45 TO RJ45 PATCH CABLE ADP-31 RADIO Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 11: Wiring Diagrams

    2-wire transmitter Analog (powered externally) CH 8 CH x Input SHIELD POWER SUPPLY 3-wire transmitter CH x Analog (powered externally) Input POWER SUPPLY 4-wire transmitter CH x Analog (powered externally) Input POWER SUPPLY Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 12: Wiring Diagram

    +24V supply. Note: Any channels sharing the same power source (e.g. +24V from module or a field power supply) are no longer isolated from one other. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 13: Ao-3 Wiring Diagram

    +12V Ou tput SUPPLY Note: polarity can 0V / Common be reversed. CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 +12V Ou tput 0V / Common Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 14: Wiring Diagram

    External Power LOAD Supply. Note: POWER polarity can be CH 2 SUPPLY reversed. COMMON COMMON 1 CH 3 CH 4 COMMON 2 CH 5 CH 6 COMMON 3 CH 7 CH 8 COMMON 4 Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 15: Wiring Diagram

    CH 15 CH 16 +12V Output 12V Output is sourced from the backplane power rail. This output is not isolated. Care should be exercised +12V Output to avoid shorting or overloading this output. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 16: Relay Board (Tel Rel 002) Wiring Diagram

    Each channel has 3 relay contacts (NO,C,NC) connected to two 3-way terminal blocks Wiring Example LOAD When the output channel is set ON, POWER External Power Supply. the load is energised SUPPLY Note: polarity can be reversed. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 17: Wiring Diagram

    * Optional link for DC SUPPLY ONLY. Enables fuse fail LED ‘FU’ on module. CAUTION! When link is installed, a maximum voltage of 30V AC or DC can be used to power the common. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 18: Wiring Diagram

    FIELD CONTACT DI CH x External power POWER supply. Note: polarity SUPPLY can be reversed. Common DO CH x LOAD External Power POWER Supply. Note: polarity SUPPLY can be reversed. Common Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 19: Wiring Diagram

    FIELD CONTACT module. DI CH x External power POWER supply. Note: polarity SUPPLY can be reversed. Common DO CH x LOAD External Power POWER Supply. Note: polarity SUPPLY can be reversed. Common Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 20: Wiring Diagram - Ac Supply

    12 VDC SUPPLY (NOMINAL) CAUTION! Connecting the (MUST BE ISOLA TED FROM FIELD SUPPLY ) DC Supply in reverse may cause damage to the PS-11. 96 TO 340 VDC SUPPLY (ALTERNA TIVE TO USING BATTERY TERMINALS) Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 21: Wiring Diagram

    +V and –V are wired to pins 7 and 8 (12V Supply Input) of the orange BL9 connector on the BA-4 backplane. 1 2 3 4 5 Voltage Adjust (13.8V) BA-4 +12V Supply Input 0V Supply Input Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 22: Solar Panel Installation

    North when in southern hemisphere 10. Level Probe Installation Hang level probe near access hatch Connect level probe to analog input Hang level probe (Eg. Platypus from www.ecefast.com.au) 100mm above floor of tank (above sludge) Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 23: Antenna Installation

    USE N TYPE MALE WHEN CONNECTING TO LIGHTNING ARRESTOR OR USE BNC MALE WHEN CONNECTING STRAIGHT TO RADIO* (A LIGHTNING ARRESTOR IS HIGHLY RECOMMENDED) Wiring of antenna connectors is detailed in the next section. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 24: Antenna Cable Selection And Installation

    11. Fit front insulator over contact to butt against rear insulator. 12. Press sub-assembly into body as far as possible and engage clamp nut. 13. Holding body and cable rigid, tighten clamp nut to compress plain gasket and retain cable. Kingfisher PLUS+ Installation Manual 2.6 www.cse-semaphore.com/mykingfisher Page...
  • Page 25: Return Of Goods

    If you would like to return RTU modules or equipment for testing or repair, please carry out the following steps: Request a Return Authorisation (RA) number from your Kingfisher representative  Complete all details on a RA form (please use the supplied form as a master copy or download ...
  • Page 26 RETURN AUTHORISATION RETURN AUTHORISATION NUMBER RETURNS PROCEDURE CSE-Semaphore Australia Pty Ltd Unit 8, 3-5 Gilda Court Request an RA No. from CSE-Semaphore Australia Pty Ltd MULGRAVE, VICTORIA 3170, AUSTRALIA PH: (61) 3 8544 8544 Complete all details on form then fax copy to CSE Semaphore FAX: (61) 3 8544 8555 ABN: 006 805 910 Return form with goods to address shown on right...