GOK SmartBox 4 BASIC PRO Assembly And Operating Manual

GOK SmartBox 4 BASIC PRO Assembly And Operating Manual

Electronic remote level gauge for up to four tanks

Advertisement

Quick Links

Assembly and operating manual
®
SmartBox
4 BASIC PRO
Electronic remote level gauge for up to four tanks
CONTENTS
ABOUT THE MANUAL ............................................................................................................................. 1
SAFETY ADVICE ..................................................................................................................................... 2
PRODUCT-RELATED SAFETY ADVICE ................................................................................................. 2
GENERAL PRODUCT INFORMATION .................................................................................................... 3
INTENDED USE ...................................................................................................................................... 3
USER QUALIFICATION ........................................................................................................................... 4
ASSEMBLY .............................................................................................................................................. 4
ELECTRICAL INSTALLATION ................................................................................................................. 5
START-UP ............................................................................................................................................... 7
PROGRAMMING ..................................................................................................................................... 7
NOTES ON PROGRAMMING ................................................................................................................ 11
OPERATION .......................................................................................................................................... 13
TROUBLESHOOTING ........................................................................................................................... 13
FUNCTION CHECK ............................................................................................................................... 13
MAINTENANCE ..................................................................................................................................... 14
RESTORATION ..................................................................................................................................... 14
DISPOSAL ............................................................................................................................................. 15
TECHNICAL DATA ................................................................................................................................ 15
LIST OF ACCESSORIES ....................................................................................................................... 15
PROBES AND ACCESSORY PARTS .................................................................................................... 16
WARRANTY .......................................................................................................................................... 16
TECHNICAL CHANGES ........................................................................................................................ 16
SERVICE ............................................................................................................................................... 16
CERTIFICATE NO. ................................................................................................................................ 16

ABOUT THE MANUAL

• This manual is part of the product.
• This manual must be observed and handed over to the operator to ensure that
the component operates as intended and to comply with the warranty terms.
• Keep it in a safe place while you are using the product.
• In addition to this manual, please also observe national regulations, laws and
installation guidelines.
Translation of the original operating instructions / part no. 28 680 57 a
Version 12.2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartBox 4 BASIC PRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GOK SmartBox 4 BASIC PRO

  • Page 1: Table Of Contents

    Assembly and operating manual ® SmartBox 4 BASIC PRO Electronic remote level gauge for up to four tanks CONTENTS ABOUT THE MANUAL ..........................1 SAFETY ADVICE ............................. 2 PRODUCT-RELATED SAFETY ADVICE ....................2 GENERAL PRODUCT INFORMATION ....................3 INTENDED USE ............................3 USER QUALIFICATION ...........................
  • Page 2: Safety Advice

    ® SmartBox 4 BASIC PRO This assembly and operating manual is aimed at users and operators of this product. These persons must have read and understood the assembly and operating manual. The physical and psychical requirements for proper and safe handling of the product must be ensured at all times! SAFETY ADVICE Your safety and the safety of others are very important to us.
  • Page 3: General Product Information

    You will find a list of operating media with descriptions, the relevant standards and the country in which they are used in the Internet at www.gok.de/liste-der-betriebsmedien. Installation location • with protection type IP54, indoors and outdoors, if protected against the weather...
  • Page 4: User Qualification

    ® SmartBox 4 BASIC PRO USER QUALIFICATION This product may be installed only by qualified experts. These are personnel who are familiar with setting up, installing, starting up, operating and maintaining this product. "Equipment and systems requiring supervision may be operated only by persons aged at least 18, who are physically capable and who have the necessary specialist knowledge or who have been instructed by a competent person.
  • Page 5: Electrical Installation

    ® SmartBox 4 BASIC PRO Installation of the display unit Mount the display unit to the wall in a suitable position. 1. Open the display unit by removing the bottom cover. 2. After loosening the 2 screws, open the display unit by removing the cover. 3.
  • Page 6 ® SmartBox 4 BASIC PRO Observe the safety precautions and the assembly and operating instructions of connected devices. Connection line between indicator and probe unit Voltage Probe supply 20 V DC Connection – Probe connection cable SmartBox 4 Probe 1 - terminals ...
  • Page 7: Start-Up

    ® SmartBox 4 BASIC PRO START-UP Operation elements and display The device is adjusted once when it is put into operation. After start-up the device operates in display mode with the top closed. The display is a two-line LCD display with 2 x 16 characters. The display has blue background lighting for best readability in all lighting conditions.
  • Page 8 ® SmartBox 4 BASIC PRO Menu Input function Input value Tank: 1 Tank:________ Select the tank (tank: 1 to tank: 4) to enter the corresponding values. (This step is not displayed if Tank:________ ® only one probe is connected to SmartBox 4 BASIC Tank:________ Tank:________...
  • Page 9 ® SmartBox 4 BASIC PRO Menu Input function Input value 3.Tank shape Select Tank shape with [Enter] Linear Default setting linear tank, rectangular tanks, vertical cylinders, basement-welded steel tanks. Cylindric cylindrical tank with arched ends horiz. horizontal tanks, tubular tanks typical shape for steel outdoor or buried tanks.
  • Page 10 ® SmartBox 4 BASIC PRO Menu Input function Input value 4.Tank Adjust the tank volume with [+] / [-] (100%). The default volume setting is 0 L. The value must be set. ___________L Please see a volume table for the highest value, if available.
  • Page 11: Notes On Programming

    ® SmartBox 4 BASIC PRO EXAMPLE FOR PROGRAMMING Example: 4 Basement tanks for 15.000 litres fuel oil, litre display, linear steel tank Inner height 220 cm, (fill level tank 1 = 125 cm) ® SmartBox 4 BASIC PRO with 4 standard probes 0 - 250 mbar Menü-Schritt Eingaben / Auswahl Tank number:...
  • Page 12 ® SmartBox 4 BASIC PRO Menu Setting Description 10.Trim xxx.x cm Entry option for the reference height for the 2-point height measurement, for other probe measurement range or for an unknown density. Subtract 1.0 cm from the actual measured level and enter this value. Calibrate:No If activated (Yes), the display in menu steps 1+2 is Calibrate:Yes...
  • Page 13: Operation

    ® SmartBox 4 BASIC PRO Menu Setting Description 17b. Data output: Data output to H Box (only with DTM-2): H protocol Deactiv • Deactivated Data: Litres • Output in litres Data: Level • Output in level 18.Language Language: German,English,French,Spain [+] / [-] / [Enter] Names: [+] / [-] / [Enter] Name Tank 1: Suggested name...
  • Page 14: Maintenance

    ® SmartBox 4 BASIC PRO TROUBLESHOOTING Error code Significance Error E1 The set value is invalid Error E2 Measured value too small (I < 3.7 mA  probe defective) Error E3 Measured value too great for zero point calibration (level probe must not be immersed) Error E4 Measured value not plausible.
  • Page 15: Disposal

    ® SmartBox 4 BASIC PRO CERTIFICATE Our management system is certified according to ISO 9001, ISO 14001 and ISO 50001, see: www.gok.de/qualitaets-umwelt-und-energiemanagementsystem. TECHNICAL DATA Indicator Action Typ 1.B (according to EN 60730-1) contamination degree 2 (according to EN 60730-1) Rated impulse voltage...
  • Page 16: Probes And Accessory Parts

    WEEE-Reg.-No. DE 78472800. Regler- und Armaturen-Gesellschaft mbH & Co. KG Obernbreiter Straße 2-18 • 97340 Marktbreit / Germany Tel.: +49 9332 404-0 • Fax: +49 9332 404-43 E-Mail: info@gok-online.de • www.gok-online.de • www.gok-blog.de 16 / 16 part no. 28 680 57 a...

Table of Contents