Table of contents 1 Introduction Condition of liability Guarantee conditions Protection against frost Safekeeping Declaration of conformity Safety Precautionary measures Appropriate utilization 2 Installation SAFETY INSTRUCTIONS FOR MOUNTING AND INSTALLATION Location and Mounting Water Supply Air supply Supply of Detergent and sanitizer 3 Operation Rinsing Foaming chemical 1...
This guarantee becomes void if changes or repairs have been implemented by non-authorized persons. Any claims under the guarantee will only be accepted if they are announced to FOAMICO immediately after the damage has been observed. This guarantee becomes void as soon as the system changes ownership.
Any other kind of application or use beyond this is considered to be inappropriate and deviant concerning the requirements, and may lead to dangerous situations. FOAMICO is not liable for any sequential damages brought about by this. Appropriate utilization includes the following: The instructions, regulations, and recommendations given in this manual.
It is recommended to keep it under 1,50 bar. It is recommended to install a strainer and a stop valve just before the mainstation. Use Foamico filters and valves...
3 Operation Rinsing 1. ATTENTION! Make always sure that the valve, POS. K, POS. A, POS. E and POS J, fig. 4.1 are closed. 2. Mount the rinsing hose with the coupling in POS. E, fig. 4.1 and make sure the valve is closed. 3.
disconnected. Foaming chemical 3 only (7003311-12-14-15-17-18) 1. ATTENTION! Make sure that the valves POS. L, fig. 4.1 are closed. 2. Mount the rinsing hose with the coupling POS. M, fig. 4.1 3. Make sure the low-pressure valve/gun at the end of the hose is closed. 4.
Page 8
Figure 4.1 A: Connection for water supply J: Coupling for the disintegrated chemicals foam chemicals 1 B: Connection for air supply K: Coupling for the disintegrated chemicals foam chemicals 2 D. Handle for choosing between rinsing and L: Coupling for the disintegrated chemicals foam foaming operation.
Page 9
TROUBLESHOOTING Fault Cause Action No rinsing pressure. Booster or main station not Start booster/or main station. started. Too many users on the same Check maximum number of users. time. The ball valve at the inlet of the Open the ball valve. system is not opened.
It will dilute the chemical and result in none or bad foam quality and to low concentration ATTENTION! Non- return valves should be checked once every week. It is recommended to change every 1-2 year Use only Original Foamico non-return valves. PSU 0127- 7003313-16-19-20 15-04-2019...
SUCTION FILTER / CHEMICAL HOSE The suction filter for chemical should be clean once every week. It is recommended to change filter TECHNICAL DATA Unit PSU 0127- Water: Min./Max. Inlet pressure 12/25 Max. Water consumption l/min. Max. Temperature °C Pipe dimension inlet inch ½"...
Pipe system – rinse circuit. Part number: 1002303 -1002280. Figure 6.2 Spare parts – pipe system – rinsing circuit PSU 0127- 7003313-16-19-20 15-04-2019...
Page 16
QTY. Description Description1 Beschreibung 1001666 Ball / shaft for 2 injector system Kugle - Welle für 1002337 Ball gasket for 2 Injector system Kugeldichtung 1002279 Block part 2 prediluted chemicals Hauptteil für 1002174 Top plate for block 2 Injector system Top für block 1000533 Bearing for shaft...
Ersatzteile Sprühschaum kreis Teilnummer 1001787-1001793 Figure 8.4 Spare parts Foam circuit QTY. Description Description1 Beschreibung 1001786 House for Prediluted chemical Gehäuse 1001794* House for Water Gehäuse 1000719 Nut for union Blok part Schraube für Verschraubung 1001684 Ball for check valve Ø14mm Ceramic Kugel f.
Flow diagram PSU 0127-5 and 8 Flow diagram PSU 0127-6 and 9 PSU 0127- 7003313-16-19-20 15-04-2019...
Page 22
PSU 0127 Inlets Outlets A. Water inlet from booster or main station C2. Chemical 2 Inlet disintegrated chemicals C1. Chemical 1 Inlet disintegrated chemicals C3. Chemical 3 Inlet disintegrated chemicals C4. Local chemical Inlet. E. Outlet for rinsing D. Air inlet Components 8.
7 Name plate 1. COMPANY NAME 2. PRODUCTION DATE 3. SERIAL NUMBER 4. ITEM NUMBER 5. MODEL TYPE 6. MAXIMUM ALLOWED FLOW 7. MAXIMUM TEMPERATURE IN 8. MAXIMUM PRESSURE CELSIUS 9. MIN/MAX INLET PRESSURE. 10. POWER 11. CURRENT 12. VOLTAGE 13.
Decleration of conformity Declaration of Conformity We FOAMICO declare under our sole responsibility that the SU NEXT 0127 1 – 5. SU NEXT 0150 1 – 5. SU NEXT 0227 1 – 5 SU 0127 Light. SU 0150 Light. SU 0110 Light SU 0127-DF Baseline.