b-intense b-control deluxe Operating Instructions Manual

For infrared cabins, 230 volt

Advertisement

Quick Links

DE
EN
FR
NL
Bedienungsanleitung
b-intense
Operating Instructions
b-intense
Manuel d'utilisation des cabines
à infrarouges b-intense
Gebruiksaanwijzing b-intense
infraroodcabines
inkl. Anschlussplan der b-control Steuerungen
incl. installation manual of the b-control units
avec instructions de montage des systèmes de commande b-control
incl. montagehandleiding b-control besturingsinrichtingen
© b-intense
®
Version 01/2021
Infrarotkabinen
®
infrared cabins
®
INFRAROTKABINEN
®
®
230 Volt
Made in Austria

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the b-control deluxe and is the answer not in the manual?

Questions and answers

Summary of Contents for b-intense b-control deluxe

  • Page 1 ® 230 Volt Operating Instructions b-intense infrared cabins ® Manuel d’utilisation des cabines à infrarouges b-intense ® Gebruiksaanwijzing b-intense ® infraroodcabines inkl. Anschlussplan der b-control Steuerungen incl. installation manual of the b-control units avec instructions de montage des systèmes de commande b-control incl.
  • Page 3: Table Of Contents

    ® Operation of the b-control units Effects of wellness supplements b-intense ® moments App and Bluetooth function Infrared programs Cleaning and care of the b-intense ® infrared cabin Maintenance instructions Disposal of the b-intense infrared cabin ® Certificate of Warranty...
  • Page 4 ® advantages and with all your senses. We wish you great pleasure and enjoyment every time you use your exclusive b-intense ® infrared cabin and, to ensure you get the best use from your purchase, we would like to make you familiar with a few operating instructions.
  • Page 5: General Safety Guidelines

    TÜV Austria and positively evaluated by the Austrian Institute ® of Technology Seibersdorf. All electrical components comply with CE safety regulations. Check the b-intense heaters for any foreign bodies before use to prevent ®...
  • Page 6: General Safety Information

    4. The IR cabin must not be operated on a multiple socket (fire hazard). 5. If used commercially, a professional annual check of the electrical installation must be ensured by the operator. Only original b-intense ® component parts are safe for use. The use of not certified components can lead to damages or injuries.
  • Page 7: General Warning Notices

    All repairs must be performed by a qualified operations, in case of illness, injuries, engineer authorized by b-intense ® . The pregnancy or in the case of plastic or electrical components must not be opened.
  • Page 8 A distinct redness in the exposed back area ist normal and desired, and happens due to the increased blood circulation. If the redness is still visible more than 3 hours after application, reduce the radiation intensity or the duration of use the next time. For questions or ambiguities please write a message to office@b-intense.at.
  • Page 9: General Application Notes

    General application notes b-intense infrared cabins can be used Use a towel while sitting in the cabin. ® by the whole family. The temperature in the b-intense A b-intense infrared cabin doesn‘t ® ® infrared cabin reaches between 25° need preheating. Just sit down, switch it and 40°C.
  • Page 10: Scope Of Application Of B-Intense ® Infrared Cabins

    › In case of visual damage of the cabin contact b-intense ® › Never open the electrical components of the b-intense ® › In case of damage on the supply cable disconnect the b-intense from the power supply and contact b-intense ® ®...
  • Page 11 Notes for safe use › Use the b-intense ® infrared cabin according to the intended purpose defined in the operation manual. › The b-intense infrared cabin must be used with naked and at first dry back. ® › The b-intense infrared cabin MUST NOT be used without headrest and backrest.
  • Page 12 Warnings and contraindications Although every application of heat basically involves the risk of damaging the skin, infrared radiation offers the advantage of contactless heat transfer, thus the natural defense reaction is least affected. Normally, unpleasant sensations or slight pain in the irradiated area, which are already noticeable prior to burns, lead to behavioral changes (we move away from the source of radiation), thus we are protected by our own natural averting reactions.
  • Page 13: Operation Of The B-Control Units

    The limit of 50% during the first 5 minutes allows the body to adjust optimally and gently to the heat supply and to increase the efficiency of the application. › LED coloured light (only included in b-control deluxe control unit) › Floor heating at 100%...
  • Page 14 › via USB stick (not enclosed) * The b-control deluxe plays mp3 and wav files. The memory size of the used USB stick should not exceed 32GB and must be formatted in FAT16 and FAT32 file system. There cannot be more than 3000 music files in the main directory.
  • Page 15: Effects Of Wellness Supplements

    ® The human organism unconsciously reacts to colours, physiologically (concerning the body) and psychologically (concerning the soul). The effect of colours is a very individual matter, allthough the physiological effects are prominent in the b-intense ® infrared cabin. The b-intense colour light offers different options to choose from.
  • Page 16 ® app in your restrictive app store. Therefore, open the app store and search for „ b-intense“ or „b-intense moments“. You can open the app after downloading it. When you first open the b-intense app you will be given a brief introduction. First you need to define a user, so that statistics and self-created ®...
  • Page 17: Infrared Programs

    In the course of time you will notice how your own body reacts. The optimal choice of program depends on your per- sonal well-being. Enjoy the programs which are developed by infrared experts and increase the effectiveness of your b-intense ®...
  • Page 18 The focus is on muscle relaxation and pain relief in the back area. We sit and a lot stand in our daily life, especially the back and neck area is strained. With the b-intense user program ®...
  • Page 19 Preheating (only with b-control deluxe) Duration: 15 or 30 minutes, until 28°C are reached – no coloured light Select one of the “Preheating” programs, if you want to preheat your b-intense infrared cabin. All radiators are at maximum power and ®...
  • Page 20 28-38°C. Therefore we recommend our customers to heat the cabin up to this temperature before starting a b-intense user program. This program is ®...
  • Page 21 › Remaining time of the program › Current intensity of the back heater in the program progress › Current temperature in the cabin (only for b-control deluxe) › Adjustment of intensity course of the program (–20% ... +20%, +/– = 0%)
  • Page 22 › Seat assignment for the program* › Current intensity of the back heater in the program progress › Current temperature in the cabin (only for b-control deluxe) Example status display for the seat "Right" › Adjustment of intensity course of the program (–20% ... +20%, +/– = 0%)
  • Page 23 If you select your individually created program via tablet or mobile phone, the name “Custom” appears on the display of the control. The remaining parameters are shown as usual. Example status display for an individually defined user program created in the b-intense ® moments app, activated for both seats...
  • Page 24 + and –. Decide according to your experience and condition. Note: You can also adjust the intensity of the user program in your b-intense moments App. Press the button „status“ and choose your seat. ®...
  • Page 25: Cleaning And Care Of The B-Intense ® Infrared Cabin

    ® › Metal components: b-intense ® recommends a mild, lukewarm soap sud Use a lint-free microfiber cloth for cleaning. Never use abrasive or pungent detergents! Disconnect the b-intense ® infrared cabin from the power supply for cleaning. Cleaning artificial leather Wiping the material with a regular wet cotton cloth is sufficent for basic cleaning.
  • Page 26: Maintenance Instructions

    The b-intense ® infrared cabin requires no special maintenance. The infrared lamps are not subject to aging and have full power until the end of their lifetime. Original spare parts can be ordered via b-intense ® Disposal of the b-intense infrared cabin ®...
  • Page 27: Certificate Of Warranty

    › The infrared lighting tubes come with a 10 year warranty (for PRIVATE use only) starting on the date of purchase, provided that any defect is not due to external damage or handling by unqualified persons. All other parts of the b-intense ®...
  • Page 28 Printing and typesetting errors excepted. b-intense GmbH ® KEEP THESE INSTRUCTIONS SAFE FOR FUTURE REFERENCE AND HAND branch office of THEM OVER WITH THE B-INTENSE INFRARED CABIN IF THERE IS A ® CB-Capital Beteiligungs- GmbH CHANGE OF THE USER OR OWNER. Am Jungfernberg 17...
  • Page 29: Annex

    In case ® of visible damage to the packaging, please contact the b-intense office immediately. The cabin must not be assembled until release.
  • Page 30 In case of visible damage unplug the ® b-intense from the power supply and contact us via office@b-intense.at. ® Before working on the controller, the power supply must be switched off on all poles (pull the main plug) and prevented it from being switched on.
  • Page 31  The power lead from the power module to the control panel is not plugged in properly. Control can be turned on, heaters do not warm up, temperature on the display > 140 °C (temperature sensor only included for b-control deluxe): ...
  • Page 32 Annex Technical data Technical data b-control deluxe controls Dimensions of power module: 310 x 200 x 50 mm Dimensions of control unit (front): 220 x 92 mm Cut-out for the control unit: 215 x 82 mm (depth 20 mm) Power module:...
  • Page 33 Annex Connection plan b-control deluxe RECHTE Seite RIGHT Side Temperaturfühler / temperatur sensor PT1000 Lüfter / fan Lautsprecher / speaker Weisslicht / white light Farblicht / coloured light...
  • Page 34 Annex Connection plan b-control basic RECHTE Seite RIGHT Side...
  • Page 35 Annex Connection plan b-control single RECHTE Seite RIGHT Side...

This manual is also suitable for:

B-control basicB-control single

Table of Contents