GRÄF & MEYER System family EVA 16 M/S EVA 16 M EVA 16 S EVA Line Manual english Rev. 4.33d -E- 121214 Dec. 2012 EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 1 - GRÄF & MEYER 12/2012...
Priority – Administration ( EVA 16 M respective EVA 16 S only ) ..... 22 External components : ....................23 Standard – microphone-desks : ( EVA 16 M respective EVA 16 S only ) ....23 3.1.1 EVA 16 SYS 80 ( EVA 16 M respective EVA 16 S only ) ........24 3.1.2...
Page 4
System setups ( examples ) ................... 76 Planning a system / Help ..................... 80 Tips for planning and installation : ................84 Technical Data ......................85 EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 4 - GRÄF & MEYER 12/2012...
In order to submit the connection of all components and all functions in an electro installation box, there is an optional external I/O-Board, connected via Standard Dsub-25pin-cable to the central unit EVA 16 M/S . In addition, there were dry relay contacts like “general fault“ and “obligation-call“.
Obligation relay to bypass external speaker-level-control (on optional I/O-Board) Automatic program-mute and audio low cut in case of 24V-operation Up to 10 units stackable ( master/slave - procedure) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 6 -...
Supervision of up to eight (8) power-amps (100V), connected via two (2) trans- former-balanced outputs When using in combination with a system EVA 16 M/S , one or two of the EVA 16 audio outputs will be connected to the audio inputs of the EVA Line.
10 POWER - LED green 11 ERROR - LED orange 12 covered switch „ALARM 1“ 13 locked connector for handheld firemic 14 firemic handheld (optional ) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 8 - GRÄF & MEYER 12/2012...
Page 9
I/O extension card ( including EVA 16 FP FirePanel ) handheld firemic EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 9 - GRÄF & MEYER 12/2012...
[ 3 ] button [ 2 ] button [ 1 ] button [ PRG ] POWER - LED green ERROR - LED orange EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 10 - GRÄF & MEYER 12/2012...
Page 11
ERROR – LED, orange Indicating an actual present error; on POWER UP LED is blinking for a short time. LC-Display , 2 x 20 characters EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 11 - GRÄF & MEYER 12/2012...
[ PRG ] [ T3 ] during powerup Only the language selection will not be affected from this factory reset. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 12 - GRÄF & MEYER 12/2012...
( return to standard display view by pressing [ PRG ] two times - or by waiting a few seconds, then the system returns automatically to the standard view. ) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 13 - GRÄF & MEYER 12/2012...
8B Out programming-mode Pinout “Future2“ : external mains failiure - external mains failiure – battery error programming-mode nc.. battery error EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 14 - GRÄF & MEYER 12/2012...
Page 15
Only one firemic at a time allowed for the connector on the front panel, the firemic1 connectors on the back panel or the firemic1 port on the I/O extension card ( including EVA 16 FP FirePanel ). EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 15 -...
Page 16
AUX 1 program In / AUX 2 program In.) Indication relays: general fault / emergency / power fail On the back panel of the central units EVA 16 M/S fault messages are available as follows : general fault / system error :...
Page 17
Connection terminal bus EVA 16 SYS 80CH NOTE: all the phoenix plugs needed for the system-setup are included and come with the unit. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 17 - GRÄF & MEYER 12/2012...
Speaker out zone 1B . . . … 100V from amp for zone 8 Speaker out zone 8A Speaker out zone 8B EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 18 - GRÄF & MEYER 12/2012...
Page 19
Functions and connection similar to EVA 16 M/S : mains connector 230 V: mains switch ON / OFF : 24V connector : RS232 interface D-Sub 9pin(m) : cascade RJ45-connector : error relais general / emergency / supply audio out to spare amp...
The line-input of the standard amplifier will be connected to one of the outputs Out CH1 ... Out CH4 of the EVA 16 M ( f.e. Out CH. 4 ). The 100V-output of the standard-amplifier feeds the input connector of the desired output-relay.
The correct position of the files on the card may be checked on EVA 16 M/S : Push red button [ PRG then, Push button [ T4 ] The system will show sequentially the number and the name of the corresponding MP3-file.
I/O-board considering the correct pinout; careful connect the shielding ! Use a CAT5-cable and a 25pin SubD-cable to connect the I/O-board to the main unit EVA 16 M ( ref. 3.3 ) The second RJ-45-connector on the I/O-board is only mentioned for the use with patchcables.
“music 1” .. “music 4” at the same time. After pushing the button [ 1 ] , the microphone desk returns immediately to standard mode/display. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 24 -...
Page 25
5 seconds, ALARM 4 starts and the display shows : ALARM Button P = STOP The alarm can be stopped by pushing the button [ P ] again. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 25 - GRÄF & MEYER 12/2012...
Selecting the menue language by pressining and holding on of the buttons 1 (german), 2 (englisch) oder 3 (french) during power- up/connecting to the bus. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 26 - GRÄF & MEYER 12/2012...
Page 27
0828). Internal supervision of data line and microcontroller function. All buttons on desktop station and corresponding functions programmable on EVA 16 M master unit; f.e.: turning on/off music completeley. Programmable user-specific groupings like Allcall, Groupcalls and Emergencall - including their correspondent priority levels. - All safety-relevant buttons covered .
Page 28
Usable settings ( rear view ): example: address = 5 , no siren <-> switchable music on / off EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 28 - GRÄF & MEYER 12/2012...
Page 29
– or appearing a new fault, so the buzzer starts working again. ( In this case, the desk-top microphone station comes with a second labeling se - buzzer ON/OFF - to replace the default type.) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 29 -...
No programming required, this terminal is consequently passive. The routing for the buttons TA1 .. TA2 has to be set in section SYS 4/2 on EVA 16 M/S. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 30 -...
EVA 16 M/S No programming required, because this terminal is consequently passive. The routing for the buttons TA1 .. TA4 has to be set on EVA 16 M/S. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 31 -...
( including EVA 16 FP FirePanel ) No programming required, because this terminal is consequently passive; the routing for the buttons TA1 .. TA4 has to be set on EVA 16 M/S. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 32 - GRÄF &...
( including EVA 16 FP FirePanel ) No programming required, because this terminal is consequently passive. On EVA 16 M/S the routing for the push-to-talk button has to be set in the Fire- Mic programming section EVA 16 M/S and EVA Line Rev.
Control elements: 4 LED indicated switches; for starting the emergency call in up to 4 programmable emergency zones of the EVA 16 M/S. ( Programming:….. go to AUDIO/LEVEL, then go to TEXTE/AUX/ALARM - then go to FIRE PANEL 1..4 … ) 6 LED indicated inputs for connecting to a fire alarm system.
Page 35
COM to CLOSE. For monitoring by a fire detection system connect the change-over contact as follows : 600R CLOSE OPEN EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 35 - GRÄF & MEYER 12/2012...
Page 36
NOTES : For each EVA 16 M or S there has to be used a separate EVA 16 FP FirePanel ( there are solutions with only one FirePanel together with more than one EVA 16 ; please contact us if required )
EXTERN This unit provides on an external board identic connections with identic naming separated from the rear panel of the master-unit EVA 16 M/S. Furthermore the connection point for FirePanel is provided here. There is an EMERGENCY RELAY ( NOTFALL ) that provides two (2) “normally closed”...
Page 38
( FirePanel only) power supply ( FirePanel only) Do not connect 0V of power supply to 0V of push-to-talk-button data EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 38 - GRÄF & MEYER 12/2012...
Ra = 10k , installed on the back panel of EVA 16, has to be removed; the termination moves to the end of the alarmline to the external alarm contact. Two resistors 4k7 required as shown ( illustration: example for wiring ) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 39 -...
Page 40
It only can be stopped at the central unit. When an alarm-box started an alarm signal, it’s failure can‘t stop the message replay. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 40 -...
The relay board EVA REL was developed to implement a lot of switching and additional features. It provides a lot of decoding functions for bus-signals or discret wired ports EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 41 -...
„contact-function“ providing a 4-way-switch matrix 4x relay blocks equipped with dual turnover contact ( common / normally closed / normally open ) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 42 - GRÄF & MEYER 12/2012...
Page 43
Output of relay blocks #1 - #4 functional decoder „global“ - function Switch matrix „contact - function“ funktional decoder „bus-function“ switch matrix „bus-function“ functional switch decoder matrix EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 43 - GRÄF & MEYER 12/2012...
R1=0 / R2=1 / R3=1 / R4=0 in this example an activated function would trigger relay 2 relay 3 EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 44 - GRÄF & MEYER 12/2012...
OFF / ON / OFF / OFF Pushing button 4 / port4 can trigger a request to an external sound system EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 45 - GRÄF & MEYER 12/2012...
More than one card EVA 16 REL 4 may be connected. The power supply of the logical part of the electronics comes via RJ45-cable. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 46 - GRÄF & MEYER 12/2012...
1011 1100 1101 1110 1111 Text1 - Code 98H = mit 1001 (für >9<) und 1000 (für>8<) = 1001 1000 Beispiel : EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 47 - GRÄF & MEYER 12/2012...
Page 48
Code 55H 0101 0101 EVATER80+firemics+alarm global Code 56H 0101 0110 Using the switches ”GLOBAL” all relays were triggered by the selected function. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 48 - GRÄF & MEYER 12/2012...
[ PRG ] [ T3 ] Only the language selection will not be affected from this factory reset. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 49 - GRÄF & MEYER 12/2012...
Pressing the button [ T3 ] now starts the installation-run ... In case of EVA 16 S and /or EVALINE units are connected to EVA 16 M by cascade port, their installation run will start automatically with the run on EVA 16 M.
( there may be 1, two or three amplifiers ) OUT: LINE OUT: LINE OUT: LINE Searching for a spare amp SPARE AMP: INSTALLED ( here: successful ) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 51 - GRÄF & MEYER 12/2012...
Page 52
During the installation-run, the installer has to take care that all the relevant components were identified with reasonable values of parameters. Otherwise, not identified alarm-lines and components will not work afterwards. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 52 -...
Page 53
EVA 16 SYS FT desktop type xxxxxxxx xxxxxxxx A request on an AUX – Input will cause a display text similar to the following : EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 53 - GRÄF & MEYER 12/2012...
Page 54
After a successfull installation run the display shows : EVALINE SYSTEM: OK Just as on EVA 16 M/S, the installer of the system has to initialize this installation run mandatory ! During the installation run, the installer hast o take care, that the system recognizes all relevant components.
If “- - dB“ appears as a level value, this input source is disabled for the actual output sum ( also refer to Chapter „Installation“ ) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 55 -...
In the same way the activation of a spare amplifier has to be reset; using the same keystroke sequence, the system will be set to standard mode. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 56 -...
Page 57
If an error message appears in system EVA 16 M/S, you have to inform immediately the installation-company or the technican of the service company, which is assigned to maintain the system ! An exact specification of the error/type can be displayed at the central unit :...
Page 58
All announcements and alarm tones can be heard ! During announcements – depending on the configuration - the internal measurement functions will be blocked. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 58 - GRÄF & MEYER 12/2012...
Page 59
EVA SYS 80 with address 1 is damaged … ( capsule or/and request ) It may take 40 … 75 sec. to detect such an effect. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 59 -...
Page 60
. => serious problem The problem is announced instantly. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 60 - GRÄF & MEYER 12/2012...
Page 61
Exclusively on master/slave systems on slave system can appear the following message : 9) Bus-connection broken CAT5 - CONNECTION the connection to the EVA 16 M (Master) is broken. Probably the slave-system works correct as local a stand-alone-system; external alarm start or announcements can no longer be triggered from master =>...
ROGRAMMING EVEL AND ROUTING DISABLING AND ENABLING OF AUDIO SOURCES This is an example for a standard display view of a EVA 16 M/S : zone 1 music 1 SYSTEM_OK EVA16M To reach the PROGRAMMING-Mode, behave as follows : After pressing the red button [ PRG ], the SELECTION –...
Page 63
1 of a terminal EVA 16 SYS 4/2 ( … TER4/2 ) [ T1 ] (NEXT) increases the number of the button 01,02, … 80 which is to edit EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 63 -...
“[ PRG ] [ PRG ] [ PRG ]” it appears like: T1=NEXT T2=LEVEL ( EVA 16 M/S only ) T3=INST. T4= NF/REL By pressing button [ T1 ] the system reaches the SOURCE - Config Menu T2= CHIME ON...
NOTE: In this mode there may be more than one request on the different alarm lines, but only the one with the highest priority will be performed exclusively in its audio- and routing functions ! EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 65 -...
[ PRG ] the system returns to the previous menu ... or after 10 seconds = IMP. TOLERANCE without any button activity. (04) SMALL EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 66 - GRÄF & MEYER 12/2012...
) are switched off until the system will be restarted by pressing the red [ PRG ] button. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 67 - GRÄF & MEYER 12/2012...
Page 70
Change values by [ + ] and [ - ] buttons Select other parameter by pushing -->| respect. [ Tab ] To return press [ ENTER ] EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 70 - GRÄF & MEYER 12/2012...
Page 71
To return press [ ENTER ] The presentation for the buttons = 21..40, = 41..60, = 61..80 und = ALARM-TEXT-AUX-FIRE will be in the similar way EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 71 - GRÄF & MEYER 12/2012...
Page 72
To edit text 2 pushing button > 2 < type new title on keyboard ( max. 12 characters ) confirm by pressing >RETURN< a.s.o. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 72 - GRÄF & MEYER 12/2012...
Quit EVAMON by selecting the button [ EXIT ]. Remember to reconnect all the removed RJ45-connectors on the rear side of EVA 16 EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 75 - GRÄF & MEYER 12/2012...
When a running ALARM is stopped by pressing the red PRG-button on a EVA 16 S slave unit, only alarming in this slave unit is stopped, other connected EVA 16 M/S – systems are not affected. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 76 -...
Page 77
EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 77 - GRÄF & MEYER 12/2012...
Page 78
( The position of this shown detail is in the rear, left near the mains connector … ) EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 78 - GRÄF & MEYER 12/2012...
Page 79
NOTE: When using Master/Slave-Systems in COMMON Mode, on the Slave- SD-card there have to be used dummy files(silence) except the 16kHz testtone. Signals from master an slave will be mixed during the alarm playout. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 79 -...
Tips for a clean and error free running of the speaker line-monitoring Basics : The units EVA 16 M / EVA Line are designed and developed for a classical A/B – wiring ( … the predictions of the actual regulations as for example EN 60849 … ) .
The power plug is for disconnecting the unit from main power, keep the plug reachable. Only use on main plug with protection earth pin present. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 85 - GRÄF & MEYER 12/2012...
Page 86
The power plug is for disconnecting the unit from main power, keep the plug reachable. Only use on main plug with protection earth pin present. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 86 - GRÄF & MEYER 12/2012...
Page 87
Jumper2: when jumper1 is removed, internal sounder works during an alarm or a microphone call. EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 87 - GRÄF & MEYER 12/2012...
Page 88
D 66459 Kirkel-Limbach / Saar Tel.: 06841 / 93 4 93 – 0 Fax.: 06841 / 93 4 93 – 10 Info@gplusm.de www.gplusm.de EVA 16 M/S and EVA Line Rev. 4.33d -E- - english, Page 88 - GRÄF & MEYER 12/2012...