IMPORTANT: READ CAREFULLY BEFORE USE AND KEEP FOR FUTURE REFERENCE.

SAFETY INSTRUCTIONS

Check the heater for damage before installation. If the supply cord is damaged, it must be replaced by the
Ÿ
manufacturer or it's service agent.
The heater must be installed by a qualified electrician in accordance with current wiring regulations. The
Ÿ
heating must be connected to the fixed wiring and protected by 30mA residual current device (RCD) and a
suitable fuse or circuit breaker.
The heater must be connected to a circuit with means for disconnection from the supply having contact
Ÿ
separation of at least 3mm in all poles.
This heater is a Class I appliance and to comply with the Wiring Regulations it must be earthed.
Ÿ
The ceiling surface must be capable of supporting the weight of the heater. If in doubt please check.
Ÿ
The heater must not be installed at a height less than 1.8m from the floor.
Ÿ
Do not install the heater directly below electrical outlets when using the optional ceiling mounting bracket.
Ÿ
WARNING: This heater is not equipped with a device to control the room temperature. Do not use this heater in
Ÿ
small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant
supervision is provided.
This heater must not be used in ambient temperatures exceeding 30°C.
Ÿ
Do not use in hazardous areas.
Ÿ
The surface of the panel can be cleaned using a soft cloth and a mild aqueous mild detergent. The heater must
Ÿ
be switched off, allowed to cool and isolated from the electrical supply before cleaning.
Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years
Ÿ
and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its
intended normal operating position and they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8
years shall not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION — Some parts of this product can become very hot and cause burns. Particular attention has
Ÿ
to be given where children and vulnerable people are present.
DESCRIPTION & SPECIFICATION
CR radiant heaters are designed to provide primary, localised or perimeter heating in residential, commercial and
industrial buildings. For optimum performance the heaters should be installed between 2.4m and 3.5m above floor
level either by direct ceiling mounting using the optional bracket (CRB), laid into a standard 24mm "T" section
suspended ceiling grid or suspended from the ceiling using suitable chains or wires.
The heaters can be switched ON/OFF manually using a suitable double pole switch to provide localised heating.
However for optimum temperature control we recommend using a suitable room thermostat. For advice please
contact your distributor.
Model
Power
Voltage
Current
Dimensions (L x W x H)
Weight
Minimum installation height
Recommended installation height
IP rating
CR Radiant Ceiling Panel Heaters
Installation and User Instructions
3CR
300W
230V~
1.3A
595 x 595 x 25mm
6.2kg
1.8m
2.4 - 3.5m
IP 55
6CR
600W
230V~
2.6A
1195 x 595 x 25mm
11.9kg
1.8m
2.4 - 3.5m
IP 55

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3CR and is the answer not in the manual?

Questions and answers

Summary of Contents for Flexel 3CR

  • Page 1 FLEXEL CR Radiant Ceiling Panel Heaters Installation and User Instructions IMPORTANT: READ CAREFULLY BEFORE USE AND KEEP FOR FUTURE REFERENCE. SAFETY INSTRUCTIONS Check the heater for damage before installation. If the supply cord is damaged, it must be replaced by the Ÿ...
  • Page 2 WARRANTY FLEXEL CR radiant ceiling panel heaters are supplied with a 2 year warranty from the date of purchase. The warranty does not cover damage resulting from transportation, incorrect installation or operation. Any heater found to be faulty will be repaired or replaced.

This manual is also suitable for:

6cr

Table of Contents