Do you have a question about the IKDV01 and is the answer not in the manual?
Questions and answers
Summary of Contents for Ampcontrol IKDV01
Page 1
IKDV01 KEYPAD PUSH BUTTON SYSTEM User Manual Issue: R4 Mar 2020 ECN: 9436 Ampcontrol User Manual Part No: 110910 Designed and Manufactured in Australia by Ampcontrol CSM Pty Limited.
IKDV01 Keypad Push Button System Issue: R4 Date: 03/2020, ECN: 9436 Safety and other Warnings WARNING! This safety alert symbol identifies important safety messages in this manual and indicates a potential risk of injury or even death to the personnel. When you see this symbol, be alert, your safety is involved, carefully read the message that follows, and inform other operators.
Before You Begin We would like to take a moment to thank you for purchasing the IKDV01 Keypad Push Button System. WARNING! To ensure the correct and safe operation of this equipment the user is to become completely familiar with the safety requirements and correct operating procedures detailed in this user manual.
Ampcontrol immediately. Notify Ampcontrol within 7 days (maximum) in case of shortages or discrepancies, according to the packing list. This action will help ensure a speedy resolution to any perceived problems. Keep a record of all claims and correspondence.
Experience with, or understanding of, this equipment is essential for the safe installation and removal of the equipment. If in doubt, contact Ampcontrol immediately. Mechanical and or Electrical installation, and maintenance of plant and equipment, must only be carried out by appropriately trained, qualified and competent personnel.
When power is first applied to the keypad (via the IKDV01 Interface) all LEDs on the push button keys will flash simultaneously until communication is established. This flashing may continue if wiring to the keypad is faulty or the Interface Module itself is faulty.
To ensure the Stop key is functioning correctly, a special test function has been attached to this key. When power is first applied to the system the stop LED on the IS Keypad flashes continuously. The Stop outputs on the IKDV01 Interface Module are held in an off state.
IKDV01 Keypad Push Button System Issue: R4 Date: 03/2020, ECN: 9436 To add further safety to the Keypad / Interface system, a “watchdog timer”, continually tries to open the stop relay output contact. If the keypad system is functioning correctly, the timer is being continually reset and the output remains closed.
Appendix A – Drawings. When the IKDV01 Interface Module has been set to Mode 2 the Programmable Logic Controller controls the outlet of the DCB. The main differences to the Standard Operation are as follows: 1. No stop reset is required on power up 2.
A PLC Output is connected to the start input (terminals 25 and 26) on the Integrated Protection Relay. Operation of the Start push key operates an internal relay RL1 in the IKDV01 Interface Module. This relay output closes the PLC input.
Ampcontrol personnel only. If a fault develops return the component/s to Ampcontrol for repair. It is essential that no attempt be made to repair the component/s as any attempt to dismantle or repair them can seriously compromise the safety of the system and/or unit, and the consequence can be fatal.
IKDV01 Keypad Push Button System Issue: R4 Date: 03/2020, ECN: 9436 Appendix A – Drawings Drawing Number Description IKDB001 IKA Block Diagram IKDA003 Interface IS Module – General Details IKDA004 Keypad General Arrangement and Mounting Details The drawings appear in the following pages in the same order in which they are listed in the table above.
Page 14
IKDV01 Keypad Push Button System Issue: R4 Date: 03/2020, ECN: 9436 IKD Keypad Pushbutton System User Manual.docx IKDB003 R4 Page 13...
Page 15
IKDV01 Keypad Push Button System Issue: R4 Date: 03/2020, ECN: 9436 IKD Keypad Pushbutton System User Manual.docx IKDB003 R4 Page 14...
Page 16
IKDV01 Keypad Push Button System Issue: R4 Date: 03/2020, ECN: 9436 IKD Keypad Pushbutton System User Manual.docx IKDB003 R4 Page 15...
Need help?
Do you have a question about the IKDV01 and is the answer not in the manual?
Questions and answers