Dear customers, Please strictly follow the safety operation instructions and use the machine properly to improve the efficiency and to extend the service life of the machine. You can contact with your local distributors or directly contact us for maintenance service or any other assistance.
CONTENTS Read Before Use ..............01 Technical Parameters ............02 III. Application Fields ..............03 Features ................03 Parts List ................04 Operation Instructions ............06 VII. Trouble Shooting ..............06 VIII. Detailed List In Case ............08...
Read Before Use Before use, please check if the electric supply is 220V /50Hz (110V/60Hz for some area), and also make sure there is air filter cotton in the base air filter, not blocked. DO NOT overfill the solution tank above its Max. volume 2 L to prevent overflow.
Technical Parameters Model No. Standard type Parameter JYCD02 Power Supply AC220-240V/50Hz(110V/60Hz) Power 1000W Tank Capacity Spraying Volume 50-260mL / min (adjustable) Droplet Size 20-160 µ m Effective Range 3-8 m Net Weight 3.1kg Gross Weight 3.4kg Measurement 670 x 220 x 280...
Application Fields Disinfection, sanitization, sterilization, pest control and air purification for residential and many commercial and industrial applications such as: agriculture, veterinary, hospital, school, hotel, fitness centre, office buildings, warehouse, factory, etc. Features Ability to change different diameter of nozzle, controlling fog drop particle precision, to meet a variety of spray work.
Page 8
JYCD02 Electric ULV Fogger Spare Parts List Item Name Specification machine shell A JYCD02-1-01 end cap gasket JYCD02-2-01 solution tank end cap JYCD02-1-15 radiator JYCD02-2-02 power switch AC220V/10A refrigeration circuit board only JYCD02 motor damping washer JYCD02-1-04 series motor O-ring 25*2.65/NBR70°...
Operation Instructions Fill solution to the tank and fasten the cap. Choose the right nozzle sizes according to your need. The nozzle sizes referring to the above parameters sheet. Fix the nozzle and turn on to spray. Trouble Shooting Malfunction: the machine doesn't work. Causes plug connection is loosed, bad contact;...
Page 10
Malfunction: the motor is working but no atomization coming out. Causes The sprayer nozzle is blocked. Solution: disassemble the nozzle and sprayer head; pass a thin iron wire through the small hole of nozzle several times to unclog, and then assemble the components to the original place.
Detailed List In Case Item Name Remark Fogger body Carbon brush Spare parts reserved Belt Operating Insruction Manual Product Qualification Certificate...