Summary of Contents for Raven SmartYield Pro

  • Page 1 SmartYield™ Pro Installation Manual P/N 016-0171-566 Rev. C 12/15 E26333 Copyright 2015...
  • Page 2 GPS, GNSS, SBAS, etc.). Therefore, Raven Industries cannot guarantee the accuracy, integrity, continuity, or availability of these services and cannot guarantee the ability to use Raven systems, or products used as components of systems, which rely upon the reception of these signals or availability of these services.
  • Page 3: Table Of Contents

    Connecting an Aftermarket Rotary Switch ................. 28 Chapter 6 SmartYield™ Pro Control Node Installation....... 29 Control Node Installation Recommendations ................29 Bracket Mounting ........................30 SmartYield Pro Node Harness Connections ................31 SmartYield Pro Node Harness Connections ..............31 016-0171-566 Rev. C...
  • Page 4 Table of Contents CAN and Power Connections .................... 31 Chapter 7 Envizio Pro™ Series Connection........33 SmartYield™ Pro Installation Manual...
  • Page 5: Important Safety Information

    • Follow all safety information presented within this manual. • If you require assistance with any portion of the installation or service of the SmartYield Pro sensor system, contact a local Raven dealer for support. • Follow all safety labels affixed to system components. Be sure to keep safety labels in good condition and replace any missing or damaged labels.
  • Page 6 Chapter 1 Harness should not contact or be attached to: • Lines and hoses with high vibration forces or pressure spikes • Lines and hoses carrying hot fluids beyond harness component specifications Avoid contact with any sharp edge or abrading surfaces such as, but not limited to: •...
  • Page 7: Instructions For Hose Routing

    Important Safety Information Protect harnesses from: • Foreign objects such as rocks that may fall or be thrown by the unit • Buildup of dirt, mud, snow, ice, submersion in water and oil • Tree limbs, brush and debris • Damage where service personnel or operators might step or use as a grab bar •...
  • Page 8 Chapter 1 For hose sections that move during machine operation: • Allow sufficient length for free movement without interference to prevent: pulling, pinching, catching or rubbing, especially in articulation and pivot points • Clamp hoses securely to force controlled movement to occur in the desired hose section •...
  • Page 9: Introduction

    Installation of the SmartYield Pro system varies depending upon the specific machine make, model, and model year. Despite variations, the installation of the SmartYield Pro system will require the following steps: Install the Raven field computer in the vehicle cab within reach of the vehicle operator. Review the display installation manual for specific instructions.
  • Page 10: Kit Contents

    Chapter 2 Mount the SmartYield Pro control node on the outside of the vehicle cab. Before mounting the node, review Chapter 6, SmartYield™ Pro Control Node Installation. Mount the yield sensors to the clean grain elevator. Mount the optional moisture sensor to the clean grain elevator or to the grain tank loading auger in the grain hopper.
  • Page 11 Mounting Bracket Extension Plate Refer to the SmartYield Pro Calibration and Operation Manual for details on the calibration and to help determine if extension plates are necessary. Refer to “Yield Sensor Paddle Extension Plates” on page 18 for additional information on installing extension plates.
  • Page 12: Point Of Reference

    Chapter 2 Factory Rotary Potentiometer Tee Cables (D/N 054-9000-007) FIGURE 2. Header Height Sensor Amp Header Height Sensor Deutsch SuperSeal Tee (P/N 115-9000-016) DTM Tee (P/N 115-9000-018) (Used on certain models of Gleaner, Massey (Used on certain models of Case IH Ferguson, Claas, and Challenger Harvesters) Harvesters) Header Height Sensor Deutsch...
  • Page 13: Care And Maintenance

    Technology Division web site: www.ravenhelp.com Sign up for e-mail alerts to receive notice when updates for your Raven products are available on the Raven web site. At Raven Industries, we strive to make your experience with our products as rewarding as possible.
  • Page 14 Chapter 2 SmartYield™ Pro Installation Manual...
  • Page 15: Yield Sensor Installation

    The ‘X’ measurement must be made perpendicular from the side wall on the lift side of the clean grain elevator. If your specific harvester make and model is not listed, contact a local Raven dealer or the Raven technical support center for additional instructions.
  • Page 16 While the yield sensors provide some tolerance for misalignment when installed, it is important to align and level the sensors as carefully as possible. A SmartYield Pro installation tool kit (P/N 117-0171-468) is available with drill bits and a square which may be helpful with leveling and aligning the yield sensors during installation.
  • Page 17: Yield Sensor Locations

    Optional Extension Plate Refer to the SmartYield Pro Calibration and Operation Manual for details on the calibration and to help determine if tabs are necessary for your specific harvester. See the Yield Sensor Paddle Extension Plates section on page 18 for details on installation of the paddle extension plates.
  • Page 18: Yield Sensor Mounting

    If the clean grain elevator is non-magnetic, use the supplied rivets to mount the yield sensors using the provided brackets. Place the brackets against the elevator as a template and drill pilot holes for rivets to mount the brackets. Two sensor mounting bracket types are supplied in the SmartYield Pro kit: Sensor Bracket Types FIGURE 4.
  • Page 19 Yield Sensor Installation Measure and mark the desired installation location on the outside wall of the clean grain elevator. Refer to the Yield Sensor Locations section on page 13 for machine specific measurements required for the yield sensors. Example Yield Sensor Mounting Location FIGURE 5.
  • Page 20 Chapter 3 Drill pilot holes (bit provided in optional installation tool kit) at the marked locations. Use caution when drilling the pilot holes and do not push the drill bit to full depth. Once the pilot hole is drilled, use the bit to feel for a paddle or other components of the clean grain elevator. If necessary, operate the elevator to move the paddles or other obstructions away from the drilling area.
  • Page 21 Yield Sensor Installation Yield Sensor Hinged Mounting Bracket FIGURE 8. Lens Assembly Sensor Jam Nut Note: Overtightening the lens assembly on the sensor body may dislodge the lens from the cap. It is only necessary to thread the lens assembly onto the body a few turns. If the lens is dislodged from the cap, loosen the cap and press the lens back into the lens assembly.
  • Page 22: Yield Sensor Paddle Extension Plates

    An extension tab kit may be required for installations on Gleaner, New Holland or Massey Ferguson harvesters. Tabs may also be necessary for other harvesters if the SmartYield Pro system has difficulty achieving a good calibration. Refer to the SmartYield Pro Calibration and Operation Manual for details on the calibration and to help determine if tabs are necessary for your specific harvester.
  • Page 23: Riveted Paddle Chains

    Yield Sensor Installation Manually advance the elevator to the next paddle. Repeat the process for each paddle on the clean grain elevator. Example View of Clean Grain Elevator and Paddles FIGURE 11. Before After Riveted Paddle Chains Use one of the following procedures to attach extension plates to paddles riveted to the elevator chain. Welding Extension Plates Open the access panel or clean out door in the bottom of the clean grain elevator.
  • Page 24 Chapter 3 SmartYield™ Pro Installation Manual...
  • Page 25: Moisture Sensor Installation

    • Generally, the center of the clean grain elevator access panel is the best place to mount the SmartYield Pro moisture sensor. Keep the sensor surface clear of the elevator walls and ensure adequate clearance for the mounting hardware.
  • Page 26: Clean Out Door Mounting

    Chapter 4 Clean Out Door Mounting Select a location on the grain elevator clean out door where the moisture sensor and mounting hardware will not interfere with the operation of the clean out door and the sensor surface is not covered by the elevator walls.
  • Page 27: Installation On The Grain Tank Loading Auger

    Moisture Sensor Installation Example of Mounted Moisture Sensor FIGURE 2. Replace the clean out door on the clean grain elevator. Installation on the Grain Tank Loading Auger Keep the following items in mind when selecting a location to mount the moisture sensor: •...
  • Page 28: Grain Tank Loading Auger Mounting

    Kit P/N 117-9000-012 will help with vibration. Moisture Sensor Revisions As of 2015, there are four hardware revisions of the grain moisture sensor available for use with the Raven SmartYield Pro system. The sensor revisions require different calibration values to be programmed via the field computer to ensure system accuracy.
  • Page 29 Moisture Sensor Installation Moisture Sensor Identification FIGURE 4. Earlier Revision Sensors Revision “Y” Sensors Raven 063-9000-012 Raven 063-0173-629 Part Identification Tag 016-0171-566 Rev. C...
  • Page 30: Header Cutout Switch Installation

    Depending upon the specific harvester make and model, there are a few additional cutout switch options which may provide additional features when used with the SmartYield Pro system. For additional information on the available header cutout switch options, contact a local Raven dealer.
  • Page 31 Chapter 5 Factory Rotary Potentiometer Examples FIGURE 1. Note: Contact a local Raven dealer for additional assistance with locating the factory header height potentiometer. SmartYield™ Pro Installation Manual...
  • Page 32 Using the appropriate header height tee cable (see Figure 2 on page 27), reconnect the factory potentiometer and factory cable. The remaining branch of the tee cable will be connected to the SmartYield Pro node harness. Refer to Chapter 6, SmartYield™ Pro Control Node Installation for connection information.
  • Page 33: Connecting An Aftermarket Rotary Switch

    Connecting an Aftermarket Rotary Switch An aftermarket rotary switch kit (P/N 117-9000-007) is available if a factory rotary sensor is not installed from the manufacturer or is not compatible with the available Raven header sensor cables. Aftermarket Rotary Switch (D/N 054-9000-007) FIGURE 3.
  • Page 34 Header Cutout Switch Installation Rotary Sensor Alignment FIGURE 4. 2.5V 3.5V 1.5V 4.5V 0.5V 016-0171-566 Rev. C...
  • Page 35 Chapter 5 SmartYield™ Pro Installation Manual...
  • Page 36: Smartyield™ Pro Control Node Installation

    S martYield™ Pro CHAPTER C h a p t e r 6 Control Node Installation Control Node Installation Recommendations Keep the following items in mind when selecting a location to mount the SmartYield™ Pro control node: • Mount the control node in a location where the unit will not interfere with normal machine operation. The box must not be jarred or struck by any vehicle components during operation.
  • Page 37: Bracket Mounting

    Chapter 6 Bracket Mounting Refer to the following procedure to mount the SmartYield Pro control node using the node mounting kit (P/N 117-0171-299). Insert a 1/4” bolt (P/N 311-0049-103) through the recessed side of the ceramic magnet assembly (P/N 418-0000-013). The threaded side of the bolt should extend past the flat side of the magnet assembly.
  • Page 38: Smartyield Pro Node Harness Connections

    SmartYield™ Pro Control Node Installation SmartYield Pro Node Harness Connections Review the following sections to connect the SmartYield Pro node harness to the node and sensors: SmartYield Pro Node Harness Connections Insert the large, rectangular connectors on the SmartYield Pro node harness to the SmartYield Pro node.
  • Page 39 Chapter 6 SmartYield™ Pro Installation Manual...
  • Page 40 Note: Complete the installation procedures provided with the Envizio Pro series field computer prior to connecting the SmartYield Pro system. Connect the 2-pin Deutsch connector on the yield monitor cable to the connector labeled ‘Switched Power’ on the field computer cable.
  • Page 41 Chapter 7 SmartYield™ Pro Combine Cable with Envizio Pro Series Cable FIGURE 1. Connection Diagram (D/N 054-9000-002) SmartYield™ Pro Installation Manual...
  • Page 42 Introduction SmartYield Pro Overview 5 Junction Box Installation Recommendations 29 Kit Contents Additional Components 7 Optional Components 8 Standard SmartYield Pro Kit Contents 6 Moisture Sensor Installation Recommendations 21 Updates Yield Sensor Installation Mounting Brackets 14 Paddle Extension Plates 18 Recommendations 11 016-0171-566 Rev.