Page 3
98/58/EEC, an alarm system must be installed in any house that is mechanically ventilated. Please note that the product liability clause of Big Dutchman' general terms and conditions of sale and delivery specifies that an alarm system must be installed.
INTRODUCTION ......................7 MOUNTING GUIDE ...................... 7 Mounting of 307pro together with 378 ..............9 Mounting of 307pro....................9 Mounting of Auxiliary Contactor ..................10 Mounting of Extra 24 V Power Supply ................11 2.2.1 Power Supply 24 V, 2.1 A in Box ......................11 2.2.2...
Page 5
CL 74CVA Stepless 0-10 V ......................42 12.6.4 CL 75A ON/OFF 24 V ........................42 12.6.5 CL 75A Stepless 24 V ........................43 12.6.6 CL 75A 24 V 0-10 V ......................... 43 12.6.7 CL 75A Stepless 230 V without Potentiometer ................44 307pro Climate computer...
Circuit Diagrams and Cable Plans INTRODUCTION This document contains a collection of examples of cable plans and circuit diagrams to be used for the installation of a 307pro. The document may contain sections that are irrelevant to the house in question. MOUNTING GUIDE 307pro Temperature sensor Humidity sensor, Temp.
Page 8
Cooling pump Magnet valve Blowheater Local heat Tunnel cooling Heating shunt Step 1 Step 2 Step 16 Figure 2: Outline of connections 307pro Tunnel 307pro Temperature sensor Humidity sensor, Temperature sensor Pressure sensor Outside temperature sensor Heat recovery unit Alarm...
Circuit Diagrams and Cable Plans 1 Mounting of 307pro together with 378 307pro Figure 4: Mounting of 307pro with 378 2 Mounting of 307pro 1) Place the computer with the display ( ) at eye level for the daily user.
Do not place the contactors in the climate computer. The contactors cause electrical disturbance which can make the computer reset/restart. Place the contactors in an external box next to the climate computer. Figure 6: Mounting of auxiliary contactor Contactor or auxiliary relay must not be installed in the climate computer. 307pro Climate computer...
The extra power supply (B) (power supply 24 V 2.1 A, printed circuit board) can be mounted in a pre-existing extension box together with the I/O module. Figure 8: Mounting of extra 24 V power supply, printed circuit board 3 Mounting of Emergency Opening See Technical Manual regarding the emergency opening. 307pro Climate computer...
On the shady side of the house to avoid the sun. Take into account that the altitude of the sun varies with the seasons. As much in the open as possible, but protected from rain and snow. 307pro Climate computer...
Connection of backup units to 307pro In areas with an unstable power supply, one of the following backup units can be mounted in front of 307pro to compensate for frequent power failures. With/without Emergency Opening 378 Type of backup unit...
+24 V max 0,8 A Figure 10: Connection of extra 24 V power supply Connect power supply to 307pro with a multi-conductor cable.The connected products determine the number of conductors in the multi-conductor cable. The multi-conductor cable is used for input and output signals from the connected products and to the minus wire of the power supply.
If connecting 7 or more I/O modules, the ribbon cable must be supplement with two wires (D) must be between the internal power supply (A) and the terminal block on the seventh I/O module. minimum of 1.0 mm Figure 12: Connection of seven or more I/O modules 307pro Climate computer...
Circuit Diagrams and Cable Plans 6 Connection through Installation Menu of the Computer The connection terminals in the 307pro computer are universal, allowing different components to be connected to the individual terminals. Therefore, consider the circuit diagrams in this document as examples only.
6.2 Printing the Installation Setup via the PC Simulator The software for the 307pro house computer is also available as a simulator variant for installation on a PC. Having set up the installation menu using the PC simulator, the setup can be saved as a semicolon delimited file on the PC.
• The LO-power relay module with make contacts can control e.g. fan heating 230 V winch motor 24 V DC winch motor with emergency opening • The switch module is used together with both the HI-power relay module and the LO-power relay module 307pro Climate computer...
Page 20
• Set the S5 slide switch on the override switch module to ON There are no settings on the HI-power relay module and it cannot control 24 V winch motors either. Figure 14: Settings for winch motor 307pro Climate computer...
ON Figure 15: Example of the setting of a CAN termination jumper on the basic module Figure 16: Example of the setting of CAN termination jumpers on the basic module and two I/O modules 307pro Climate computer...
Colour code on the wires in appliance with the IEC 60757 standard: Alphabetic codes for identification of colours used on drawings, diagrams, marking, etc. Letter code Colour Black Brown Orange Yellow Green Blue (incl. light blue) Violet (purple red) Grey (slate) White Pink Gold Turquoise Silver GNYE Green-and-yellow 307pro Climate computer...
Supply from emergency opening 0V-1 = Q1 terminal in Computer Supply from emergency opening 24V-1 = Q2 and Q3 terminal in Computer Supply from emergency opening 24V-2 = Q4 and Q5 terminal in Computer Supply from emergency opening 24V-12 = F6 terminal in computer/emergency opening. 307pro Climate computer...
Diode P6KE36CA Diode 1N4005 Product with mounted diode. Product with mounted TransZorb diode. The diode must be mounted with The TransZorb diode can be mounted marking ring to + on the DC supply. regardless of the polarity. 307pro Climate computer...
11.2 System with 378M ON/OFF Emergency Opening Service Room DOL 12 307pro Alarm system 378 ON/OFF House DOL 114 11.3 System with 378T Temperature-controlled Emergency Opening DOL 12 House Service Room 307pro DOL 114 378T DOL 12 = Connection box 307pro Climate computer...
CL 175 24V CL 175 230V EWA 12 230V EWA 12 24V NOTE: 230V winch motors for air inlet and air outlet cannot be connected in parallel. They must be separated by means of two contactors. See 12.6.9 307pro Climate computer...
166 - 265 m Table 4: Cable dimension for CL 75 24 V DC 11.5.5 DOL 114 24 V DC Cross section Length 1.5 mm 0 - 200 m Table 5: Cable dimension for DOL 114 24 V DC 307pro Climate computer...
DA 74CV Stepless DA 74CV Stepless 2 among several groups, depending on the number of and the power to be supplied. NOTE! Number of conductors depends on type of fan Air outlet 2 Air outlet 1 307pro 307pro Climate computer...
Air outlet 1 Air outlet 2 307pro 11.9 Fans Three-phase Fan supply voltage is divided among several groups, depending on the number of and the power to be supplied to the fans 307pro 307pro Climate computer...
ON-Delay-timer fås i mange varianter. Dette er blot et eksempel. 307pro 11.11 Fans One-phase Fan supply voltage is divided among several groups, depending on the 307pro number of and the power to be supplied to the fans 307pro Climate computer...
Max 16 A Window emergency air inlet Wall fan Heating shunt 24 V Heating shunt 230 V Relay heating Blowheater Cooling Pad cooling Electronic differential pressure sensor Auxiliary sensor or CO sensor Stir fan DOL 58 Weather Sensor 307pro Climate computer...
Circuit Diagrams and Cable Plans 12 Circuit Diagrams - Climate 12.1.1 Mains Voltage for I/O Module and Main Modulel Installation in accordance with applicable national rules; supply cable, however, min. 1.5 mm 12.1.2 Alarm 307pro Climate computer...
12.3 Internal Speed Control 12.3.1 Two Parallel Fans Eks. på klemmenummer For korrekt tilslutning se opsætningsmenuen Vis connection i 307pro 12.4 Stir Fan / Wall Fan 12.4.1 One -phase Ex. of terminal number For correct connection, See the setup menu...
Circuit Diagrams and Cable Plans 12.4.2 Three-phase Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.5 External Speed Controller 12.5.1 MC 31 Ex. of terminal number For correct connection, See the setup menu...
Circuit Diagrams and Cable Plans 12.5.2 MC 37 External Frequency Converter Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.5.3 CL 600 LPC- motorcontroller Ex. of terminal number For correct connection, See the setup menu...
12.5.4 CL 600 LPC / CL 74CO ON/OFF / Dynamic MultiStep Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro Supply from emergency opening or internal 24V Q2-Q5 Can lead to the next fan...
Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro Supply from emergency opening or internal 24V Q2-Q5 When using ON/OFF 278M and 378M, connect Q1 to B17 on the main module. 307pro Climate computer...
12.6.1 CL 74CO ON/OFF Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro Supply from emergency opening or internal 24V Q2-Q5 When installing 378 ON/OFF emergency opening, connection of the H6 is not necessary 12.6.2...
Circuit Diagrams and Cable Plans 12.6.3 CL 74CVA Stepless 0-10 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro Emergency opening -378T -378M Q2-Q5 Supply from emergency opening or internal 24V 12.6.4 CL 75A ON/OFF 24 V Ex.
Circuit Diagrams and Cable Plans 12.6.5 CL 75A Stepless 24 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.6.6 CL 75A 24 V 0-10 V Ex. of terminal number For correct connection, See the setup menu...
12.6.7 CL 75A Stepless 230 V without Potentiometer Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.6.8 CL 75A Stepless 230 V Ex. of terminal number For correct connection, See the setup menu...
Circuit Diagrams and Cable Plans 12.6.10 CL 174 ON/OFF 24 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.6.11 CL 174 Stepless 24 V Ex. of terminal number For correct connection, See the setup menu...
Circuit Diagrams and Cable Plans 12.6.12 CL 175 ON/OFF 24 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.6.13 CL 175 Stepless 24 V Ex. of terminal number For correct connection, See the setup menu...
Circuit Diagrams and Cable Plans 12.6.14 CL 175 ON/OFF 230 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.6.15 CL 175 230 V Stepless Ex. of terminal number For correct connection, See the setup menu...
Circuit Diagrams and Cable Plans 12.6.16 EWA 12 24 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.6.17 EWA 12 230 V Ex. of terminal number For correct connection, See the setup menu...
12.7 Room/Floor Heating 12.7.1 0-10 V Analogue 230 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.7.2 Relay Heating ON/OFF Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro...
Circuit Diagrams and Cable Plans 12.7.3 Room Heating 24 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro Connection box 12.7.4 Blow Heater and Stir Fan 24 V Ex. of terminal number For correct connection,...
Circuit Diagrams and Cable Plans 12.7.5 Blow Heater and Stir Fan 230 V Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro Use the same phase for all blow heaters/stir fans 12.7.6 Earny Distribution board for Earny Ex.
Circuit Diagrams and Cable Plans 12.8 Sensors 12.8.1 DOL 12 Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 12.8.2 DOL 114 Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro...
Circuit Diagrams and Cable Plans 12.8.3 DOL 19 CO Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro Connection box 12.8.4 Differential Pressure Sensor Ex. of terminal number For correct connection, See the setup menu...
12.8.5 Dynamic Air sensor Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro Run the blue and black wire separately to the climate computer where the wires should be connected in a negative terminal.
Circuit Diagrams and Cable Plans 12.9 Special Connections 12.9.1 Cooling/Humidification/Soaking Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 307pro Climate computer...
1) MultiStep air outlet: The swivel shutters are controlled by the MultiStep principle and open by turns 2) Stepless air outlets: The swivel shutters are mechanically connected and open equally much Swivel shutter DA 74CO Cable Recirculation fan 307pro Climate computer...
Connect the fans in and external fan speed controllerr MC 31. See diagram section 12.3 Internal Speed Control or 12.5.1 MC 31. Air inlet See diagrams section 12.6 Winch Motors for all Positions Air Outlet See diagrams section 12.6 Winch Motors for all Positions 307pro Climate computer...
15 Basic Circuit Diagrams - Production 15.1 Clock 15.1.1 Water Meter Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 15.1.2 24-hour Clock Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro...
15.2 Light Control 15.2.1 Light Relay Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 15.2.2 Inspection light Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 307pro Climate computer...
Circuit Diagrams and Cable Plans 15.2.3 Light Dimmer Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 15.2.4 Light Sensor Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro...
Circuit Diagrams and Cable Plans 15.3 Delivery 15.3.1 Key Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro 15.3.2 Relay Ex. of terminal number For correct connection, See the setup menu Show connection in 307pro...
Page 64
Big Dutchman International GmbH • Calveslage • Auf der Lage 2 • 49377 Vechta; Germany Tel. +49(0)4447/801-0 • Fax +49(0)4447/801-237 • big@bigdutchman.com...
Need help?
Do you have a question about the 307pro and is the answer not in the manual?
Questions and answers