Download Print this page
MasterCraft EH-4604BY Instruction Manual
MasterCraft EH-4604BY Instruction Manual

MasterCraft EH-4604BY Instruction Manual

Garage heater with remote

Advertisement

model no. EH-4604BY
IMPORTANT:
Please read this manual carefully before running
this garage heater and save it for reference.
GARAGE HEATER
with Remote
INSTRUCTION
MANUAL

Advertisement

loading
Need help?

Need help?

Do you have a question about the EH-4604BY and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MasterCraft EH-4604BY

  • Page 1 EH-4604BY GARAGE HEATER with Remote IMPORTANT: INSTRUCTION Please read this manual carefully before running MANUAL this garage heater and save it for reference.
  • Page 2 model no. 043-5120-2 | contact us 1-800-689-9928...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Technical Specifications Important Instructions General Safety Information Locating Heater Installation Instructions Operating Instructions Cleaning and Maintenance Warranty NOTE: If any parts are missing or damaged, or if you have any questions, please call our toll-free helpline at 1-800-689-9928. SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions.
  • Page 4: Technical Specifications

    EH-4604BY | contact us 1-800-689-9928 DESCRIPTION Electric utility heaters are designed to meet a variety of heating requirements by switching a few wires located in the base of the unit. Features horizontal and vertical airflow, built-in thermostat and overheating safety thermal cut-out.
  • Page 5: Important Instructions

    IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before installing or using this heater. 2. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces.
  • Page 6: General Safety Information

    EH-4604BY | contact us 1-800-689-9928 GENERAL SAFETY INFORMATION 1. Use only copper wires rated for at least 75ºC. 2. Heater airflow must be directed parallel to or away from adjacent wall. 3. Observe wall, floor and ceiling clearance requirements.
  • Page 7: Locating Heater

    LOCATING HEATER Install heater out of traffic areas, maintaining clearances stated in Figure 1. The direction of airflow should not be restricted is by columns or machinery and the airflow should avoid exposed walls rather than blowing directly on them. When more than one heater is used in an area, the heaters should be arranged so that the air discharge of each heater supports the airflow of the others to provide best circulation of warm air as indicated in Figure 2.
  • Page 8: Installation Instructions

    EH-4604BY | contact us 1-800-689-9928 INSTALLATION INSTRUCTIONS HARDWARE NEEDED You will need the following hardware, which can be purchased from your local hardware store or electrical supply house: • Adequate gauge and length of wire for your application.
  • Page 9 ADJUSTING AIRFLOW DIRECTION 1. To turn the unit when it has been installed with a single lag bolt (as shown in Figure 3a), simply turn the entire heater as needed. The unit cannot be turned horizontally if it has been installed with 2 lag bolts. 2.
  • Page 10 EH-4604BY | contact us 1-800-689-9928 CONNECTING THE POWER Terminal station Motor TGP-085 HL-YJF10 240V 60Hz Temperature sensor AC 240V / 60Hz Overheat Caution light Control panel º º Electronic circuit board Remote control Relay J1 Relay J2 Relay J3...
  • Page 11 TO PROTECT THE HEATING ELEMENT The heater includes a fan delay function to prevent risk of overheating. When turning the heater off, the unit will close the heating element first and then the fan will continue working for 60 seconds to dissipate residual heat. 1.
  • Page 12: Operating Instructions

    EH-4604BY | contact us 1-800-689-9928 OPERATING INSTRUCTIONS Figure 10 Timer Down ºF / ºC Heating (off/fan/low/high) Power INSTRUCTIONS IN NORMAL MODE Power button You can use the power button as the On/Off switch. The Power button can also be used to lock settings. Select desired heating settings with HEATING and UP/DOWN buttons, then press Power button for 10 seconds.
  • Page 13 REMOTE CONTROL Remote control has the same functions as the control panel on the heater. Power (on/off) º º ºC/ºF display Heating (off, fan, low, high) Down Timer Once the room temperature reaches the set Figure 11 point, the heater will automatically stop running.
  • Page 14: Cleaning And Maintenance

    EH-4604BY | contact us 1-800-689-9928 CLEANING AND MAINTENANCE 1. Before cleaning, make sure the power has been turned off at the main breaker panel and that the heating element of the heater is cool. 2. To maintain the external appearance of the heater, it need only be wiped occasionally with a dry duster.
  • Page 15: Warranty

    PLEASE DO NOT ATTEMPT TO OPEN OR REPAIR THE HEATER YOURSELF. DOING SO COULD VOID THE WARRANTY AND CAUSE DAMAGE OR PERSONAL INJURY. This Mastercraft product carries a one (1) year LIMITED warranty against defects in workmanship and materials. This product is not guaranteed against wear or breakage due to misuse and/or abuse.