Summary of Contents for AquaLogic ALSLT Series
Page 1
ALSLT SERIES UV STERILIZER INSTRUCTIONS Effective 2-9-16 Please read all instructions before installing and using this unit 2016 Aqua Logic, Inc., 9558 Camino Ruiz, San Diego, CA 92126 Effective 02/09/16 Ph: 858.292.4773 FAX: 858.279.0537 email: info@aqualogicinc.com website: www.aqualogicinc.com Page 1...
Page 2
IMPORTANT SAFETY INSTRUCTIONS WARNING: To guard against injury, basic safety precautions should be observed including the following: • Read and follow all safety instructions on unit and in these instructions. • Save these instructions. • Take special care to avoid possible electrical shock since water is employed in the use of this equipment.
Page 3
Thank you for selecting an Aqua Logic ultraviolet (UV) sterilizer. Each model has been designed and built to provide years of reliable service and has been fully tested under pressure before it leaves the factory. Aqua Logic has been manufacturing UV sterilizers for nearly 15 years. Aqua Logic’s UV sterilizers are in use by aquarists, aquaculture, public aquariums, educational institutions, government agencies, industry and research organizations across the US and around the world.
Page 4
It doesn’t make any difference which port you use for inlet or outlet. If you don’t mount the unit on a level surface, make sure that the water goes in the lower port and out the higher. This prevents air from being trapped in the unit.
Page 5
. Replace Lamp in all Models WARNING: Be sure to wear protective gear for your hands and eyes!! • Turn off or unplug pump. • Unplug UV ballast from outlet. • Remove both rubber end plugs from UV sterilizer by carefully pulling on ballast wire. •...
Page 6
Other Maintenance: Replace the ballast (all models): • Turn off or unplug pump. • Unplug UV ballast. • Remove both rubber end plugs from UV sterilizer by light pulling on the ballast cord. • Disconnect ballast and lamp socket from UV lamp. •...
Page 7
REMOVING ORGANICS FROM THE UV WITHOUT REMOVING THE QUARTZ SLEEVE: WARNING: Be sure to wear protective gear for your hands and eyes!! • Unplug UV from wall socket. • Isolate UV from main plumbing and drain the unit. • Make a pure chlorine bleach solution (1 cup bleach to 1 quart water) •...
Page 8
Limited Warranty Terms (PLEASE READ CAREFULLY) All UV Sterilizers manufactured by A . (hereafter called A ) are warranted against OGIC OGIC defects and workmanship for a period of one (1) year from the date of purchase by the original purchaser/end user or eighteen (18) months after date of manufacture (whichever is sooner).