Page 1
ADJUSTMENT PROCEDURES PLL ADJUSTMENT for IC-F4TR MEASUREMENT ADJUSTMENT ADJUSTMENT ADJUSTMENT CONDITIONS VALUE UNIT LOCATION UNIT ADJUST PLL LOCK 1 Operating freq: MAIN Connect a multimeter 1.3 V MAIN L11 VOLTAGE 400.000 MHz to check point CP1. Receiving 2 Operating freq: L405 400.000 MHz...
Page 2
TRIMMER ADJUSTMENT for IC-F4TR ADJUSTMENT MEASUREMENT ADJUSTMENT ADJUSTMENT CONDITIONS VALUE UNIT LOCATION REFERENCE 1 Operating freq: Loosely couple a 430.000000 MHz push[up]or[down] FREQUENCY 430.000 MHz panel frequency counter keys on the com- Transmitting to the antenna puter key-board. connector OUTPUT...
Page 3
TRANSMITTER ADJUSTMENT for IC-F4TR MEASUREMENT ADJUSTMENT ADJUSTMENT ADJUSTMENT CONDITIONS VALUE UNIT LOCATION UNIT ADJUST 1 Operating freq: Set to Connect an FM devia- MAIN R119 BALANCE flat wave 415.000 MHz panel tion meter to the an- tenna connector thro- gh an attenuator.
Page 4
RECEIVER ADJUSTMENT for IC-F4TR MEASUREMENT ADJUSTMENT ADJUSTMENT ADJUSTMENT CONDITIONS VALUE UNIT LOCATION UNIT ADJUST SQUELCH 1 Operating freq: Connect an SSG to 12dB SINAD Output LEVEL 415.000 MHz panel the antenna connector level Wide/Narrow switch:Wide and SINAD meter with Set the SSG as:...