Download Print this page

Sealey STW292 Instructions page 2

Digital torque adaptor 3/4” sq. drive - 100 - 500nm

Advertisement

fig.2
4.2.
Power On.
4.2.1. Press the Power button once (fig.2) to turn the
digital torque adaptor on. The display will initially show
"trACE" or "PtoP". After 2 seconds the LCD panel will
show "00.0".
NOTE: If left unused, the digital torque adaptor will
automatically turn off after 80 seconds.
4.2.2. Ascertain the correct size and type of socket for the
fixing to be tightened and attach it to the square drive
connector (3/4") at the base of the adaptor.
4.2.3. Insert the required ratchet wrench/drive bar into the
socket at the top of the adaptor. DO NOT use a tool
that will allow you to apply excessive force through the
adaptor.
4.3.
Selecting unit of measurement.
4.3.1. Press Mem and Peak/Trace buttons together (fig.3) and
release to select different units of torque measurement
(Nm/lb.in/kg.m) in rotation.
4.3.2. When the units are changed, the target setting will also
be changed to the new unit value.
4.4.
Setting the target torque value.
4.4.1. To increase the value, press and hold the (+) button
(fig.4), the target value will display for 10 seconds then
the LCD will display 0.00.
4.4.2. To decrease the value, press and hold the (-) button
(fig.4), the target value will display for 10 seconds then
the LCD will display 0.00.
NOTE: In use, when the torque is approaching within 20% of
the target value, the red LED will flash and an
intermittent buzzer warning will be heard, indicating that
the target torque value is nearing. When the target
torque value is reached, the red LED will illuminate and
the buzzer will sound. Immediately stop applying
pressure to the fixing.
fig.5
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: Call us for a copy of our latest catalogue on 01284 757525 and leave your full name and address including your postcode.
© Jack Sealey Limited
fig.3
fig.4
fig.6
fig.7
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
4.5.
Selecting Peak or Trace.
Selecting Peak:
4.5.1. Press and release Peak/Trace button (fig.5), the LCD
panel shows "PtoP", after 2 seconds the LCD panel
shows 00.0.
Selecting Trace:
4.5.2. Press and release Peak/Trace button (fig.5), the LCD
panel shows "trACE", after 2 seconds the LCD panel
shows 0.00.
4.6.
Memory.
4.6.1. Store reading must be under the "PtoP" mode.
4.6.2. Press "Mem" button for at least 1 second and release
(fig.6), the LCD display shows the memory number
"P01" then the torque value for this.
4.6.3. Pressing the "Mem" button again for at least 1 second,
the LCD display shows the memory number "P02"
and then the torque value. Repeat to cycle through all
memory values ("P01" is the latest reading, "P50" is the
oldest). The digital torque adaptor stores the last 50
torque value readings.
4.7.
Turning Adaptor Off.
4.7.1. If the digital torque adaptor is not used for 80 seconds,
it will automatically switch off, otherwise manually turn
it off by pressing and releasing the power button (fig.7).
5. MAINTENANCE
5.1.
Battery care and use.
5.1.1. Keep the batteries dry at all times.
5.1.2. Do not combine used batteries with new ones or mix
battery types.
5.1.3. Insert/remove the batteries carefully as described in
Section 4.1.1.
5.1.4. Never use a battery if it is cracked, broken or leaking.
5.1.5. Never heat or incinerate batteries.
5.1.6. See battery disposal information below.
5.1.7. If the digital torque adaptor is not being used for a
longer period of time, remove the batteries to prevent
damage from leakage.
5.2.
Calibration.
5.2.1. Periodic calibration is required for this product, contact
your Sealey dealer for details.
5.3.
Use only a damp cloth for cleaning. Never use any type
of liquid, aerosol cleaner, or any type of organic solvent.
Do not expose battery to intense heat or fire as
this could cause an explosion.
Battery Removal: Refer to Section 4.1.1.
ONLY dispose of or recycle according to local
authority regulations. Under the Waste Batteries
and Accumulators Regulations 2009, Jack
Sealey Ltd are required to inform potential
purchasers of products containing batteries (as
defined within these regulations), that they are
registered with Valpak's registered compliance
scheme. Jack Sealey Ltd's Batteries Producer
Registration Number (BPRN) is BPRN00705.
01284 757500
01284 703534
STW292
www.sealey.co.uk
Web
sales@sealey.co.uk
Issue No.1
26/07/12

Advertisement

loading