HOT WATER CYLINDERS
Installation Manual
120L, 180L, 250L, 350L and 400L

Advertisement

Table of Contents
loading

Summary of Contents for Waterware 120L

  • Page 1 HOT WATER CYLINDERS Installation Manual 120L, 180L, 250L, 350L and 400L...
  • Page 2: Table Of Contents

    PROTANK INSTALLERS GUIDE CONTENTS. Section One - Protank Cylinder Page 1. Model Specifications and Dimensions 2. Use and Application 3. Model Range 4. Essential Installation Requirements 5. Pipework 6. Temperature and Pressure Relief 7. Cold Water Expansion Control 8. Thermostat Control 9.
  • Page 3 A concealed 2304 Duplex stainless steel dip tube takes the cold to the bottom of the tank. WIDE RANGE 120L, 180L, 250L, 300L, 350L and 400L options. EASY WASTE CONNECTION TPR and cold water expansion valve vertically aligned for easy...
  • Page 4: Section One - Protank Cylinder Page

    50 mm Heating element mount 1&1/4” Female threaded Heating element sheath material Incoloy Heating element resistance 19.2 ohm Heating element power density 9.6 w/cm² Technical Specification Capacity 120L 180L 250L 300L 350L 400L Inlet / Outlet ports 20mm 20mm 20mm 20mm...
  • Page 5 PORT LAYOUT 120 and 180L Models 250, 300, 350 and 400L Models Model 120L 180L Model 250L 300L 350L 400L A. Inlet/Outlet height 1180mm 1710mm A. Inlet/Outlet height 1710mm 1965mm 1350mm 1520mm B. TPR Valve 985mm 1515mm B. Upper Stat / TPR Valve...
  • Page 6: Use And Application

    • Manufactured from premium grade 2304 Duplex stainless steel with a 20 year limited warranty (refer warranty terms and conditions for details). • 120L, 180L, 250L, 300L, 350L and 400L options • Available with or without the Caleffi ‘direct mount mono-block’ combo set which can save up to 50% in installation time.
  • Page 7: Essential Installation Requirements

    • The cylinder must also be suitably restrained against seismic activity according the requirements found in G12/AS1. • A suitable duty, functioning drip tray MUST be fitted to guard against unexpected failure and subsequent water damage. Waterware will not accept any consequential loss resulting from water damage if this requirement is not satisfied.
  • Page 8: Cold Water Expansion Control

    Maintenance The TPR valve should not vent under normal conditions so to ensure the valve does not become inoperable, instruct the home owner to manually open and vent every 6 months according to the maintenance section in the owner’s manual. Rotate the red knob approximately ¼...
  • Page 9: Water Quality

    6.5-8.5 Langelier Index: Between -1.0-0.8 Most metropolitan water supplies fall within these limits. If you are unsure about water quality contact Waterware for details of an authorised water testing agency. Sludge or Foreign Matter If sludge or foreign matter is present in the water supply, a suitable filter should be incorporated in the water supply.
  • Page 10: Use And Application

    SECTION TWO - CALEFFI DIRECT MOUNT COMBO SET (applicable models only) 1. Use and Application 20mm COMBO2015PRO (120, 180L models) 20mm COMBO2020PRO (250L and 300L models) 25mm COMBO2520PRO (350 and 400L models) Protanks are available with or without the Caleffi ‘direct mount mono-block’ combo set which can save up to 50% in installation time when compared to installing a traditional hot water cylinder with 3rd party valves and components.
  • Page 11: Caleffi Mono-Block Tempering Inlet Valve

    2. Caleffi Mono-block Tempering Inlet Valve TV520150 20mm (120, 180, 250 and 300L models) TV520160 25mm (350 and 400L models) **G12 - Direct Mounting of the Tempering Valve Notwithstanding acceptable methods detailed in G12, the manufacturer Caleffi have specifically engineered this tempering control valve to directly mount onto the hot water cylinder with no minimum pipe length isolation requirement as an ‘acceptable solution’...
  • Page 12 Valve Orientation The valve can be installed in any orientation and the hot and cold water supplies must be connected as shown in the indications on the valve body; hot water inlet is marked with the letter H, cold water inlet is marked with the letter C and mixed water outlet is marked with the word MIX.
  • Page 13: Caleffi Pressure Reducing Valve

    Maintenance The following aspects should be checked regularly to ensure that the optimum performance levels of the valve are maintained. Every 12 months, or more often if necessary; • Check and clean the system filters. • Verify that any check valves positioned upstream of the Caleffi valve are operating correctly, without problems caused by impurities.
  • Page 14: Caleffi Cold Water Expansion Valve

    Valve Orientation and Installation The pressure reducing valve can be installed in any orientation but should not be under water or dirt due to the risk of frost damage and dirt accumulating inside the diagram cap. The valve should be located so that the entire pipe system is operating under a controlled pressure with the possible exception of hose taps.
  • Page 15: Single Residential Domestic Warranty

    General Warranty Terms and Conditions Waterware reserves the right to make modifications and change specifications and its parts without notice. If the cylinder is being acquired for personal, domestic or household use, this warranty does not limit any consumer rights...
  • Page 16 Specific Warranty Terms and Conditions 1. All terms of this warranty are effective from the installation date or purchase date plus one month. Waterware reserves the right to verify this date.