Installation and Operation Instructions
Improper installation, adjustment, alteration, service,
Maintenance, or use can cause fire, electrical shock, or
other conditions which may cause personal injury or
property damage. Consult your supplier or Steril-Aire for
information or assistance. In regards to the statements
below, understand the signal words DANGER, WARNING,
or CAUTION. These words are universally used for overall
safety. DANGER identifies the most serious hazards which
will result in severe personal injury or death. WARNING
signifies hazards which could result in personal injury or
death. CAUTION is used to identify unsafe practices
resulting in minor personal injury or product and property
damage.
WARNING: Before performing fixture installation,
maintenance, or service, ensure unit is disconnected
from power. Electrical shock can cause injury or death.
CAUTIONS:
•
Never expose eyes or skin to UVC light from
any source. Wear gloves, face shield/glasses
(per ANSI Z87.1) and cover all exposed skin.
1.
Unpack contents and check for damage.
2.
Set base down onto its wheels. Set wheel brake if
needed.
3.
Insert 1" tube into base, aligning tube slot until tube
cannot rotate. Tighten set screw with included Allen
wrench.
4.
Set tray over 1" tube with power supplies facing down,
aligning tray holes with the collar pins.
I
C
MPORTANT
ONSIDERATIONS
I
& O
NSTALLATION
Remedial In-Room
Decontamination System
Patents 5,334,347, 5,817,276, 5,866,076, 6,245,293, 6,267,924, 6,280,686,
6,313,470, 6,372,186, 6,423,882, 6,500,267, 6,589,476, 6,627,000 & others pending.
CAUTION: Install and remove Emitters
from system only by grasping ceramic
ends, not glass (as glass may break).
NOTE: Read this entire instruction sheet
before starting the installation.
•
Do not touch Emitter glass without gloves.
Damage to Emitter may result. Oil from
fingerprints will permanently etch glass of
Emitter and weaken structure. If necessary,
clean Emitter using the included Steril-Aire
cleaning kit (isopropyl alcohol and a lint-free
wipe may be substituted).
•
Voltages outside of the range designed for the
unit will void the warranty and do permanent
damage to the entire unit.
•
Emitter contains a small quantity of mercury. If
an Emitter breaks, clean and dispose of with
care.
•
UVC energy may cause damage to non-metallic
components except for UV-rated and HVAC-
style drain pans. Select operating locations
that prevent exposure to vulnerable
components. If operating locations are limited,
such components shall be protected with UV
resistant material such as aluminum foil,
aluminum duct tape, metallic shields, etc.
PERATION
5.
Slide set collar over tube, aligning collar holes with the
pins. Push collar and tray down and tighten set screw.
6.
Ensure entire unit is not connected to power
source. Plug cord (from power supply tray) into base.
7.
Snap the clips of the cord from the power supplies
along the length of the 1" tube.
8.
Slide the ¾" tube into the 1" tube until the tube
bottoms out at its collar.
(RIDS)
Made in USA
Need help?
Do you have a question about the RIDS and is the answer not in the manual?