Download Print this page

Goldline TD-30 Quick Start Manual

Temperature display for sp controls

Advertisement

Quick Links

The TD-30 is a digital temperature display mod-
ule for use with specific Independent Energy
temperature controls. It can display both setpoint
and sensor temperature in either °F or °C and will
work with the following models:
SP-30
SP-30D
SP-300
The TD-30 can snap directly into the front cover
of the SP control, or can be mounted remotely, up
to 500 feet away. In addition to being a valuable
monitoring aid, it can be used as a service tool for
systems using the SP-30/30D/300 controls.
Display Range: -39°F to +213°F
-39°C to +100°C
Accuracy:
±1°F
Resolution:
1°F or 0.5°C
Out of Range:
displays "HI" or "LO"
Operating
15°F to 130°F
Single stage controls
Single stage controls
(DPDT output)
Dual stage controls
When directly mounted on the cover of the SP
control, the control's setpoint can be adjusted by
inserting the included 1/8" Allen wrench through
the access hole in the cover of the TD-30. Adjust-
ing the setpoint while viewing the setpoint tem-
perature on the TD-30 allows the user to set
temperatures very accurately and easily.
The TD-30 has a Max/Min feature which stores
the highest and lowest sensor temperatures in
memory. With a push of a button, the user can find
the highest and lowest temperature that the system
has reached since the last "clear". These max/min
temperatures are retained in memory even if power
is removed from the TD-30.
Environment:
0-95% rH
Connection:
All power and signals con-
nected through 4 conductor
phone cable to SP control. A
6 inch cable is included. 500
ft maximum length.
Dimensions:
4.25" x 1.75" x 1.62" overall
3.94" x 1.50" cutout for panel
mounting

Advertisement

loading
Need help?

Need help?

Do you have a question about the TD-30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Goldline TD-30

  • Page 1 1/8" Allen wrench through temperature controls. It can display both setpoint the access hole in the cover of the TD-30. Adjust- and sensor temperature in either °F or °C and will ing the setpoint while viewing the setpoint tem-...
  • Page 2 Panel the display, depressing the jack tab, and gently thicknesses from .030" to .190" (3/16") are pulling. Plug one male end into the TD-30 and the suitable. other into the SP-30/30D/300 control. Connect an extension cable between the Custom Length: A male/male extension cable can TD-30 and the SP-30/30D/300.
  • Page 3 TD-30 and the SP control, an extension cable may be is causing the error. If it is the TD-30, then return miswired. Lastly, turn power off, wait 1 minute the unit to IE for repair.
  • Page 4 8:00AM to 5:00PM East- tures. For a given temperature, the resistance is All Goldline controls use 10K thermistor sensors. accurate to +/- 1%. For a given resistance the When disconnected from the control, the sensor temperature is accurate to +/- 0.5°F.