BrewBlast™ 70CPH O&M South-Tek Systems VERSION HISTORY Revision Implemented Revision Approved Approval Reason Date Date M. Thomas 05/30/19 A. Norman 05/30/19 Initial Release...
Before personnel attempt to service the unit, ensure the power switch has been turned to the off position, then disconnect the unit’s external power cord from the building electrical power supply if possible. When servicing your system, always follow the instructions in the manuals provided by South-Tek Systems (STS). SAFETY GUIDELINES GENERAL Correct use of the BrewBlast™...
BrewBlast™ 70CPH O&M South-Tek Systems Always use approved parts when performing maintenance and repairs. Make sure that replacement parts meet or exceed the original parts’ specification. Only authorized, trained, and competent individuals are allowed to perform installation, operation, maintenance, and repair.
BrewBlast™ 70CPH O&M South-Tek Systems The generator has two filters after the air compressor; the particulate and coalescing. The Particulate has a 5 micron filter that will catch any of the larger particles. The Coalescing has a 0.1 micron filter that will catch the remaining smaller particles.
BrewBlast™ 70CPH O&M South-Tek Systems SYSTEM OPERATIONS The system has two standard run modes – Run and Standby. When the power switch is turned on, the indicator lights on the left side electrical panel will illuminate depending on what stage the generator is in; if the green light is illuminated the generator is in run mode, if the amber light is illuminated the generator is in standby waiting until the storage tank drops to the cut-in pressure.
Page 9
BrewBlast™ 70CPH O&M South-Tek Systems Optional Mounting Bracket Kit Procedures 1. All BrewBlast™ BrewBlast™ 70CPH mounting holes and optional mounting bracket holes are for ¼” screws/anchors. 2. All brackets must be installed in orientation as shown to work correctly. 3. Install the cabinet-mounting brackets on the BrewBlast™ BrewBlast™ 70CPH first with the provided bolts/lock nuts.
BrewBlast™ 70CPH O&M South-Tek Systems Item STS Part # Description BB™ BrewBlast™ BrewBlast BrewBlast™ 70CPH Nitrogen 70CPH Generator 800-133 S-100/200 12" Mounting Bracket 800-134-B S-100/200/400 18" Mounting Bracket 800-129 Type 1 Lower Wall Mount Bracket Misc 0.250" -20 x 0.750" Carriage Bolt Misc 0.250"...
Page 11
BrewBlast™ 70CPH O&M South-Tek Systems Two condensate drains for the generator are located on the bottom right of the cabinet. It is the responsibility of the installer to plumb these drains to an area where standing water is trapped or a drain is located. Failure to do so can cause a slipping hazard on the floor below the generator.
BrewBlast™ 70CPH O&M South-Tek Systems NITROGEN CYLINDER BACK-UP (BREWBLAST™ 70CPH) It is recommended that a backup system be installed in case of any unforeseen complications. A backup N Cylinder tank can be used instead of the generated nitrogen from the BrewBlast™ 70CPH. If the optional gas blender is present, it will allow the nitrogen to go through the blender to achieve the desired results.
C. If there is a leak within the unit, remove the cover and locate the issue. If you have to replace any parts, use only factory parts supplied from your distributor or South-Tek Systems. Consult the manufacturer if there are any questions.
BrewBlast™ 70CPH O&M South-Tek Systems 6. Once in “Standby” mode, wait 60 seconds. After 60 seconds, the system should remain in “standby” mode. If it doesn’t, the leak is somewhere between the check valve and the output ball valve on the tank.
NOTE: A plugged drain system will cause water and oil to carry over into the system, which will cause permanent damage to the media inside the unit. Such damage is not covered by the manufacturer's warranty. Use of filters other than those specified by South-Tek Systems could result in damages not covered by the warranty.
Page 18
BrewBlast™ 70CPH O&M South-Tek Systems 6. Wash the bowls in soapy water and rinse thoroughly as needed. Use of light air gun to remove debris is also acceptable. Make sure to always wipe down with a clean and dry cloth.
BrewBlast™ 70CPH O&M South-Tek Systems KEY CONTACTS Contact your local provider/installer with any questions regarding the performance and/or maintenance of the system. They will be best suited to answer your questions and should be readily available to help provide a resolution to any issues you may have.
South-Tek Systems within 1 week of receiving the shipment. South-Tek Systems can deny all other claims at their discretion. All warranty work shall be done at a South-Tek System facility or at a BrewBlast™ 70CPH Authorized Service Center.
Page 22
BrewBlast™ 70CPH O&M South-Tek Systems ------------------------------------------------------------------------Last Page--------------------------------------------------------------------------...