mylife Aveo User Manual

mylife Aveo User Manual

Blood glucose monitoring system

Advertisement

User guide
Blood glucose monitoring system
mg/dL
More freedom. More confidence. With mylife
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aveo and is the answer not in the manual?

Questions and answers

Petr
June 13, 2025

Jak resetovat (vymazat naměřené hodnoty) AVEO MyLife glukometr? Děkuji Petr

Summary of Contents for mylife Aveo

  • Page 1 User guide Blood glucose monitoring system mg/dL More freedom. More confidence. With mylife ™...
  • Page 2 Thank you for choosing the mylife Aveo blood glucose monitoring system. Please read this user guide thoroughly before testing ™ your blood glucose. It provides all information you need to use the product. The mylife Aveo blood glucose meter must only ™...
  • Page 3: Table Of Contents

    Averages: recall average test results from memory Limitations of the mylife Aveo meter ™ Warranty Basic setting mode Maintenance and cleaning of the mylife Aveo meter ™ How to access the basic setting mode Cleaning and disinfection of the mylife Aveo lancing device ™...
  • Page 4: Intended Use

    You may consult your healthcare professional for instructions on how to use the system correctly. Our customer support staff are available to assist you. Healthcare professionals may use the mylife Aveo blood glucose ™...
  • Page 5: Mylife Aveo Package Contents

    ➊ mylife Aveo Case ™ mylife Aveo blood glucose meter (with 2 CR2032, ➋ ™ 3 volt batteries installed) Vial with mylife Aveo test strips (10 pcs.) ➌ ™ ➍ mylife Aveo lancing device ™ Disposable mylife Lancets (10 pcs.) ➎...
  • Page 6: Bluetooth ® Wireless Technology

    App. ™ ™ Visit www.mylife-diabetescare.com/software for information on which wireless mobile devices are compatible with your mylife Aveo meter, and where/how to download the mylife App and mylife Software on your compatible device.
  • Page 7: Mylife Aveo ™ Blood Glucose Meter

    Aveo blood glucose meter ™ To turn on the meter: press any button for Data port 0.5 seconds or insert a test strip. Used to transfer data from the meter to a computer with cable To turn off the meter manually: press and hold the main button for 0.5 seconds.
  • Page 8: Operation Summary

    Aveo operation summary ™ Sleeping mode 3 seconds Basic setting mode Memory mode Measuring mode 3 seconds – Pairing a mobile device – Date – Time Averages Records Control test 3 seconds – Blood glucose target range – Volume...
  • Page 9 Sleeping or memory mode Bluetooth flight mode on/off ® 3 seconds All dynamic setting func- tions are listed with Bluetooth activation mode ® the appropriate shortcut 3 seconds on the backside of the mylife Aveo meter. ™ USB communication mode...
  • Page 10: Display And Symbol Overview

    Aveo display and symbol overview ™ Indicates the memory mode Indicates that the 2 hour post-meal alarm is set ® Indicates that an alarm (1 to 3) is set Indicates that Bluetooth is turned on Indicates that the battery is low and needs to be...
  • Page 11: Mylife Aveo ™ Test Strips

    Aveo test strip ™ The meter must only be used with mylife Aveo ™ Good Insufficient test strips. Other test strips are not accepted Sample Sample by the meter and will lead to an error message. Contact bars Gently push the test strip,...
  • Page 12 The mylife Aveo test strips should be used with fresh capillary whole blood samples, or with fresh venous ™ whole blood if drawn by healthcare professionals. Fresh venous whole blood specimens containing the anticoagulants EDTA and Heparin are acceptable. Iodoacetate or fluoride/oxalate are not recommended.
  • Page 13: Mylife Aveo ™ Lancing Device

    Aveo lancing device ™ Depth dial Lancet holder Sliding barrel End cap Lancet Release button Lancet ejector See how to use the mylife Aveo lancing device on page 15 in chapter “How to perform a blood glucose measurement”. ™...
  • Page 14 The lancing device is for use by a single user only and should not be shared with anyone. Use a soft cloth or tissue to wipe the lancing device. If necessary, a small amount of alcohol on a soft cloth or tissue may be used.
  • Page 15: How To Perform A Blood Glucose Measurement

    How to perform a blood glucose measurement Wash hands and sample Take off the end cap by Insert a new disposable Twist off and set aside Close the end cap by site with soap and turning both parts smoothly lancet firmly into the lancet the protective cap of the smoothly turning both parts warm water.
  • Page 16 Choose the penetration depth by turning the device cap. 1 for soft or thin skin; Prime the lancing device by 3 for average skin; 5 for thick or calloused skin. Finer adjustments can be made by using pulling the sliding barrel. the grid between 1, 3 and 5.
  • Page 17 click! Take one test strip from the Once the strip is inserted, the meter turns on, a beep signal is Obtain a blood sample vial and close the cap of issued (if volume is turned on) and the strip gets initialised using the lancing device.
  • Page 18 If the confirmation window is not filled in time because of abnormal viscosity (thickness and stickiness) or insufficient volume, the Er4 message may appear. The meter may switch off if the blood sample is not applied within 2 minutes of the symbol appearing on the screen. If the meters and test strips are exposed to considerable temperature variation, please wait 30 minutes at room tem- perature before performing the measurement.
  • Page 19 During the time the blood is The countdown mode will When the target range indication is set (see page 33), you will going into the test strip, the start on the display. also get an indication if your measurement is above segments will rotate clock- After 5 seconds, the test or below...
  • Page 20 You can set a marker to a blood glucose test result to indicate particular situations. You can set up one marker per measurement. Select the marker by using the left or right button and confirm the marker by pressing the main button.
  • Page 21 Expected values: Normal blood glucose levels for an adult without diabetes are below 100 mg/dL before meals and fasting* and are less than 140 mg/dL two hours after meals. * Fasting is defined as no caloric intake for at least eight hours. Reference: American Diabetes Association (Standards If your test result is below 10 mg/dL, “Lo”...
  • Page 22 The lancet is for single use only. Never share or reuse a lancet. Used test strips and lancets are potentially infected. Please dispose used test strips and lancets properly in compliance with local regulations. Take off the end cap by Stick the lancet into the Push the lancet ejector turning both parts smoothly...
  • Page 23: Automatical Data Transmission To A Mobile Device

    Bluetooth ® turned on (not in flight mode). On the mobile device the mylife App must be installed and ™ Bluetooth must be turned on. After every ®...
  • Page 24: Records: Recall Test Results From Memory

    Records: recall test results from memory The meter stores 1 000 test results with time, date, marker and target range alarm automati- cally. If your meter has stored 1 000 results, which is the maximum memory capacity, the oldest one will be deleted and the newest result will be stored.
  • Page 25: Averages: Recall Average Test Results From Memory

    Averages: recall average test results from memory The meter is able to calculate averages. To recall the average of the meas- ured test results, you have the option to choose between 1, 7, 14, 30, 60 and 90 days and the possibility to view averages per marker (pre-meal , post-meal and fasting The average will not be calculated with the results from the control solution...
  • Page 26 Repeatedly press the left Repeatedly press the left Repeatedly press the left button to view 1-, 7-, 14-, 30-, button to view 1-, 7-, 14-, button to view 1-, 7-, 14-, 60- and 90-day average values and the number of tests 30-, 60- and 90-day aver- 30-, 60- and 90-day aver- performed with the fasting symbol...
  • Page 27: How To Access The Basic Setting Mode

    How to access the basic setting mode You can enter the setting mode from sleep mode or memory mode by pressing and holding the main button for 3 seconds. Go sequentially through all the menu items by pressing the main button.
  • Page 28: Basic Settings: Pairing A Mobile Device

    In case with a mobile device and symbol is flashing and the Look for “Aveo” and the last 4 characters of the meter serial you are already somewhere confirm with the main meter is searching for a number to identify your meter.
  • Page 29 “blt SUCCESS”. versa. The display shows Repeat the procedure. the app on your mobile “blt SYNC” during synchro- 1 mobile device can device. This code must be nisation. be paired with the entered within 30 seconds. mylife Aveo meter. ™...
  • Page 30 ® the app, you can activate Bluetooth by pressing and holding the right button for 3 seconds. ® Only one mobile device can be paired with mylife Aveo . Each new pairing will overwrite the existing pairing. ™...
  • Page 31: Basic Settings: Set Date/Time

    Basic settings: set date/time After entering the setting mode, press the main button repeatedly until you see the year flashing on the screen. With the year format flash- Once the year is confirmed, Once the month is ing, press the left the month setting will confirmed, the day setting right...
  • Page 32 Once the month is confirmed, the time format setting will Once the time format is Once the hour format is confirmed, the minute setting will appear. Press the left or right button to switch confirmed, the hour appear. Press the left or right button until you see between 12 and 24 hour format.
  • Page 33: Basic Settings: Set Blood Glucose Target Range

    Basic settings: set blood glucose target range This function allows you to turn the blood glucose target range on or off and to select the desired levels for the indicators. You will be alerted any time your test result is below or above the defined blood glucose target range.
  • Page 34 The adjustable range for the lower and upper limit is the same for both and lies between 60 mg/dL and 300 mg/dL. The lower limit cannot be higher than the upper limit and vice versa. Both limits cannot have the same value.
  • Page 35: Basic Settings: Volume On/Off

    Basic settings: volume on/off The meter will beep in the following instances if the volume is turned on: When you push the main button to turn on the meter. When the test strip is inserted in the meter. When the blood sample is absorbed into the test strip and the test starts. When the test result is displayed.
  • Page 36: Basic Settings: Strip Expiration Date Indicator On/Off

    Basic settings: strip expiration date indicator on/off This mode allows you to turn the strip expiration date indicator on or off. Please note, that this mode turns the function on or off only. See page 40 to set the strip expiration date. Enter the setting mode by pressing and holding the main button for 3 seconds.
  • Page 37: Short Key Setting: Set An Alarm

    Short key setting: set an alarm This feature reminds the user when to perform a test. There are 3 sets of alarms available. The alarms ring for 15 seconds and can be silenced by pressing any button or by inserting a test strip.
  • Page 38 Set the hour by pressing the Set the minutes by pressing When turned on any alarm, left or right button. the left or right button. the display shows a statical Confirm by pressing the Confirm by pressing the AL bell symbol main button.
  • Page 39: Short Key Setting: Set/Delete The Post Prandial Alarm (2 Hours)

    Short key setting: set/delete the post prandial alarm PP2 (2 hours) This feature reminds the user when to perform a test. The PP2 alarm goes on 2 hours after setting the alarm, which usually happens after a meal. The alarm rings for 15 seconds and can be silenced by pressing any button or by inserting a test strip.
  • Page 40: Short Key Setting: Set The Strip Expiry Date

    The strip expiration date indicator functions only when the function has been activated in the main settings and when the mylife Aveo test strip is inserted. ™ To enter the strip expiration date setting, press and hold the left...
  • Page 41: Short Key Setting: Bluetooth ® Flight Mode On/Off

    Short key setting: Bluetooth flight mode on/off ® Bluetooth on = Flight mode off ® Bluetooth off = Flight mode on ® Before the flight mode can be switched on/off, you first need to configure Bluetooth by paring a device (please refer to page 28). ®...
  • Page 42 If you wish to turn on Bluetooth flight mode temporarily, In case you want to switch ® press and hold the main and right buttons simultaneously on/off Bluetooth flight ® for 3 seconds. A confirmation message appears that mode but there is no exist- Bluetooth will be switched off.
  • Page 43: Short Key Setting: Bluetooth ® Activation Mode

    Short key setting: Bluetooth activation mode ® If the meter is in sleep mode or memory mode and you are not performing a measurement but want to synchronise data with the app, you can activate Bluetooth manually by pressing ® and holding the right button for 3 seconds.
  • Page 44: Data Management

    ™ ™ meter lets you transfer data from the meter to a compatible therapy management software, such as the mylife Software, by means of a standard micro-USB cable. Data transfer from the mylife Aveo ™ ™ to the mylife Software can also be carried out by using the Bluetooth interface of the meter in ™...
  • Page 45: Quality Control Test

    Quality control test with mylife Aveo control solution ™ A quality control test should be performed whenever you want to check if your BGMS is working properly or whenever you want to practise and check the correct testing procedure. Only use mylife Aveo control solution in the control solution mode.
  • Page 46 Each time you open a new bottle of control solution, write the date of opening on the label. The control solution is usable for up to 3 months after opening the bottle, or until the expiration date printed on the label, whichever comes first. Control solution test results do not represent your blood glucose level.
  • Page 47 Gently push the test strip Press and hold the right Before opening the cap Apply the solution to the into the port (contact bars button for 3 seconds to of the control solution, shake narrow edge of the test facing upwards) until the activate the control solution the bottle well.
  • Page 48 The meter may switch off if the control solution sample is not applied within 2 minutes of the symbol appearing on the screen. If the meter turns off, remove the strip, reinsert, and start the procedure again. The control solution test results saved with the control solution symbol are not included in the averages.
  • Page 49 If control solution results are out of range, your Possible reasons why your control solution results are out of range: BGMS may not be working properly. Repeat Your control solution has expired or has been opened more than the quality control test. If your control solution 3 months ago.
  • Page 50: Battery Change

    Battery change Your meter is delivered with 2 CR2032, 3 volt batteries installed. Two new batteries will provide power to perform about 1 000 tests under normal circumstances. When the battery symbol To change the batteries Remove the used batteries appears on the display while make sure the meter is one at a time.
  • Page 51 Date and time need to be set again after each battery replacement (see page 31). In case the battery change is done when the meter is switched off and within 90 seconds, date and time data may be kept. Measurements, target range, volume and pairing information will not be deleted when changing batteries.
  • Page 52: Firmware Version Of The Meter

    Firmware version of the meter The meter allows you to query the firmware version of your mylife Aveo meter. ™ You can enter the firmware information screen from sleep mode or memory mode. The meter will display the major and minor revision.
  • Page 53: Error Messages And Troubleshooting

    Error messages and troubleshooting Error 1 Error 2 Error 3 Error 4 The inserted test strip has The blood or control solu- The temperature during the test was above or below The blood sample has been used or damaged. tion sample was applied the operating range.
  • Page 54 Please repeat the test with Please do not use the Please contact your local Please repeat the test with a mylife Aveo test strip. meter. Please contact your Ypsomed customer service a new test strip. If the ™...
  • Page 55 If the meter still does not work correctly, please contact your local Ypsomed cus- tomer service (see page 59). The display is blank even after inserting a test strip. The test does not start The test result does not even after applying match the way you feel.
  • Page 56: Limitations Of The Mylife Aveo ™ Meter

    This warranty applies only to the original purchaser of the mylife Aveo meter. ™ This warranty does not apply for any damage caused by the use of other test strips than mylife Aveo test strips. ™...
  • Page 57: Maintenance And Cleaning Of The Mylife Aveo ™ Meter

    Maintenance and cleaning of the mylife Aveo meter ™ Keep your meter and test strip free of dust, water or any other liquid. If the meter is dropped or damaged, perform a quality control test (see page 45) before performing a blood glucose test to ensure that the meter is still functioning correctly.
  • Page 58: Cleaning And Disinfection Of The Mylife Aveo ™ Lancing Device

    Cleaning and disinfection of the mylife Aveo lancing device ™ Clean the surface of the lancing device with a soft cloth dipped with clean water. Please do not immerse the lancing device into any liquid to avoid damage. The surface of the lancing device can be wiped and disinfected with 75 % ethanol. If there are...
  • Page 59: Customer Service

    We are keen to provide a comprehensive service to our customers. Please review all the instructions to ensure that you are performing all measurement steps correctly. If you have any questions, or in the event of any problems with mylife Aveo ™...
  • Page 60: Description Of Symbols Used

    Description of symbols used Manufacturer EU Representative For in-vitro diagnostic use For single use only Use by / expiration date (no matter if already opened or not) Storage temperature limitations Sterilised using irradiation Caution (consult instructions for use and warnings) CE Mark CE Mark with number of Notified Body Consult user guide...
  • Page 61: Manufacturers

    Manufacturers mylife Aveo meter, mylife Aveo test strips, mylife Aveo control solution ™ ™ ™ Manufacturer: i-SENS, Inc. 43, Banpo-daero 28-gil, Seocho-gu, Seoul 06646, Korea The products comply with In-Vitro Diagnostic Directive 98/79/EC (CE 0123). EU Representative: MT Promedt Consulting GmbH, Altenhofstrasse 80, 66386 St.
  • Page 62: Technical Specifications

    Option B: micro-USB port Test time 5 seconds (micro-USB/USB-A-type cable) Memory capacity 1 000 measurements Meter data transmission Data can be transferred to the mylife ™ management and to therapy management software, Power saving such as mylife Software. Regarding the ™...
  • Page 63: Performance Characteristics

    < 100 mg/dL Accuracy Within ± 5 mg/dL 112/168 (66.7 %) The accuracy of the mylife Aveo blood glucose monitoring ™ Within ± 10 mg/dL 157/168 (93.5 %) system was assessed by comparing blood glucose results Within ±...
  • Page 64 Precision Packed cell volume (Haematocrit HCT) The precision studies were performed in a laboratory using The hematocrit levels (15–70 %) were tested to evaluate mylife Aveo blood glucose monitoring system. the effect of hematocrit level on measurement of glucose ™...
  • Page 65 Interferences The effect of various interfering substances was evaluated in whole blood samples on glucose measurements. Interferent Difference averages Interval 1 Interval 2 50–100 mg/dL 250–350 mg/dL Acetaminophen -4.4 mg/dL -1.9 % Creatinine 0.5 mg/dL -0.6 % Ascorbic acid 0.0 mg/dL 2.6 % Dopamine -0.2 mg/dL...
  • Page 66 User performance evaluation Sodium salicylate 1.5 mg/dL 2.6 % A study evaluating glucose values from fingertip capillary Tolazamide 0.4 mg/dL 0.8 % blood samples obtained by 100 lay persons showed Tolbutamide 1.2 mg/dL 1.2 % the following results: 100 % within ± 15 mg/dL of the medical laboratory values at glucose concentrations below Triglyceride 0.7 mg/dL...
  • Page 68 Korea Korea Manufactured for MT Promedt Consulting GmbH Ypsomed AG Altenhofstrasse 80 3401 Burgdorf 66386 St. Ingbert Switzerland Germany www.mylife-diabetescare.com Ypsomed AG // Brunnmattstrasse 6 // 3401 Burgdorf // Switzerland // info@ypsomed.com // www.mylife-diabetescare.com // +41 34 424 41 11...

Table of Contents

Save PDF