Removing the Components from the Drive Module ..............23 Reinstalling the Components in the Drive Module ..............26 Replacing a Failed Environmental Services Monitor ............... 28 Replacing a Failed Power-Fan Canister ..................31 Replacing a Failed Disk Drive ....................34 SGI InfiniteStorage 120...
Page 5
List of Figures Figure 1. SGI InfiniteStorage 120 Drive Module ..............1 Figure 2. Drive Module – Front View ..................2 Figure 3. Drive Module – Rear View ..................2 Figure 4. Drive Module Status LED Locations ............... 4 Figure 5. Service for the ESM Canister is from the Rear of the Drive Module ......7 Figure 6.
Page 6
Figure 30. Power Light and Fault Light on a Power-Fan Canister ......... 32 Figure 31. Removing a Disk Drive ..................35 SGI InfiniteStorage 120...
Page 7
Table 6. Performance Specifications for the ESMs ..............10 Table 7. Power-Fan Canister Lights ..................12 Table 8. Disk Drive Ports ......................14 Table 9. Disk Drive Lights ...................... 15 Table 10. Disk Drive State Represented by Lights ..............15 SGI InfiniteStorage 120...
................InfiniteStorage 120 Hardware Topics This document is a collection of hardware topics that describe the SGI InfiniteStorage 120 drive module.
............Drive Module Specifications Drive Module Specifications The following table lists the physical and electrical specifications for the drive module.
............Environmental Specifications Environmental Specifications The following tables list the temperature, humidity, altitude, shock, and vibration specifications for the drive module.
..............ESM Canisters ESM Canisters An environmental services monitor (ESM) provides the interface between the disk drives in a drive module and the hosts.
......Environmental Services Monitor Performance Specifications Environmental Services Monitor Performance Specifications The following table lists important performance specifications for each ESM in a drive module.
The term hot swap refers to the ability to remove and replace a component in the drive module while the drive module is powered on. The InfiniteStorage 120 is a JBOD module, you must halt all I/O transfers between the module and the host system(s) before you can perform any hot swap replacement of a disk drive.
......... . . Turning Off the Power to the Drive Module Turning Off the Power to the Drive Module Follow the steps in this procedure to make sure that you correctly turn off the power to the drive module.
........Reinstalling the Components in the Drive Module Reinstalling the Components in the Drive Module If you have removed the components from the drive module, use this procedure to reinstall those components.
........Replacing a Failed Environmental Services Monitor Replacing a Failed Environmental Services Monitor This section describes how to replace a failed ESM.
Need help?
Do you have a question about the InfiniteStorage 120 and is the answer not in the manual?
Questions and answers