To Customers Thank you for selecting SMC Air-Cooled Aftercooler. For safety and long life of the product, be sure to read this Operation Manual (hereinafter referred to as the “manual”) and clearly understand the contents. ● The instructions described in this manual must be followed in addition to ISO 4414*1) and JIS B 8370*2) and other safety regulations.
Table of Contents i. Safety Instructions ·············································································· 1 1. Specifications ··················································································· 4 2. Model No. identification mark ······························································· 5 3. Working principle ·············································································· 5 4. Outer dimensions and descriptions of each part ······································ 6 5. Electric circuit diagram ······································································· 8 6.
ATX-OM-F004E Air-Cooled Aftercooler i Safety Instructions i Safety Instructions Before using the product be sure to read and understand all the important actions highlighted in this manual. i - 1 Warning: Before using this product This chapter is intended to specifically describe the safety related issues for handling the product. Read this before handling the product.
Page 5
ATX-OM-F004E Air-Cooled Aftercooler i Safety Instructions i - 3 Warning related to electricity Warning - There is a current supply part where high voltage that had been isolated by the cover panel hung in this product. Please do not drive this product with the cover panel removed. - Please go if you have enough knowledge and the experience when working and checking in the current supply part.
Page 6
ATX-OM-F004E Air-Cooled Aftercooler i Safety Instructions i - 7 Limited warranty and Disclaimer / Compliance Requirements The product used subject to the following “Limited warranty and Disclaimer “and “Compliance Requirements. Read and accept them before using the product. 『Limited warranty and Disclaimer』 (1) The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.
ATX-OM-F004E Air-Cooled Aftercooler 1. Specifications 1. Specifications MODEL HAA7 HAA15 HAA22 HAA37 Note 1) Air flow capacity L/min(ANR) 1000 2200 3300 5700 Inlet air temperature Rated MPa Inlet air pressure conditions Ambient temperature Outlet air temperature Fluid Compressed air 5~100 Inlet air temperature ...
ATX-OM-F004E Air-Cooled Aftercooler 2. Model No. Identification Mark 2.Model No. Identification Mark Symbol Applicable air compressor 7.5kW 15kW 22kW 37kW 3.Working principle Inlet air Pushbutton switch Pilot ramp Fan motor Outlet thermometer Cooled air Cooled air Cooler 2. Model No. Identification Mark HAA Series - 5 -...
ATX-OM-F004E Air-Cooled Aftercooler 4. Outer dimensions and descriptions of each part 4.Outer dimensions and descriptions of each part Outer dimensions Model HAA15-10 HAA22-14 union PORT SIZE union 4 1) Outer dimensions HAA Series - 6 -...
Page 10
ATX-OM-F004E Air-Cooled Aftercooler 4. Outer dimensions and descriptions of each part part 2) Descriptions of each part HAA7 to 22 28 29 30 HAA37 Components of aircooled aftercooler and descriptions Description Cooler Main panel Right side panel Left side panel Upper panel Front panel Rear panel...
ATX-OM-F004E Air-Cooled Aftercooler 6. Installation 6. Installation 1) Installation Location (1) The unit must be installed where maintenance and installation can be made easily. (2) The unit must be separated from the wall and the other machines 15 to over 20cm. (3) The unit must be installed in an indoor place where a lot moisture and dust are not present and the unit is well ventilated.
ATX-OM-F004E Air-Cooled Aftercooler 7. Electrical wiring 7.Electrical wiring Warning Only qualified persons are allowed to wire the product. - Before wiring, be sure to shut off the power supply. Never perform wiring work while the product is energized. - Ensure a stable power supply with no voltage surges. Ensure that an ground fault circuit interrupter with appropriate capacity for ground fault and load is used in the power supply of the product to prevent electrical shock and burnout of the compressor motor.
ATX-OM-F004E Air-Cooled Aftercooler 8. Maintenance 8.Maintenance To hold the excellent cooling capacity for a long period of time and make more effective use of the unit, the following inspection and maintenance operations must be made. [Daily check] (1) Open the drain valve and remove the drainage once and a while. (2) When an automatic drain system is used, check once and a while to see that drainage is discharged.
ATX-OM-F004E Air-Cooled Aftercooler 9. Mounting accessories (option) 9.Mounting accessories (option) Please assemble the option (accessories) with the following points. 1) Terminal Assembly (Symbol: T) (1) Mount the rubber sheet on the side panel and stick it to the location where the hole and hole of rubber sheet match.
Page 16
ATX-OM-F004E Air-Cooled Aftercooler 9. Mounting accessories (option) 2) Auto drain Assembly (Option Symbol: D) (1) Mount a nipple with sealant and an auto drain onto the drain valve. * When auto drain is used, put the after cooler body onto a mounting bench. If Option S has not been ordered, it can be provided as a separately sold part.
Page 17
ATX-OM-F004E Air-Cooled Aftercooler 9. Mounting accessories (option) 4) Dustproof filter Assembly Procedure (Option Symbol: F) Mount a dustproof filter to the rear panel on the back of aftercooler with tapping screws as shown below. HAA7 to HAA22 Dustproof filter Tapping screw 6-nominal 4 Rear panel HAA37...
ATX-OM-F004E Air-Cooled Aftercooler 10. Trouble causes and remedies 10.Trouble causes and remedies If the unit should fail, the causes may be by those pointed out in the following chart Trouble Possible Cause Remedy Switch is OFF. Turn the switch ON. Broken wire in the Repair the broken wire.