1. Introduction Thanks for purchasing this DP70 wireless multi-channel water leak detection sensor. The alarm will be triggered when water seepage is detected. The wireless signal can be received by the DP1500 Wi-Fi Gateway(sold separately) and the sensor data can be viewed on our WS View mobile application after the Wi-Fi configuration done.
3.1 Features Detects water seepage every 3 seconds. Emits loud alarm with 90dB once triggered. High or low sensor sensitivity selectable to meet different requirements. Works with DP1500 Wi-Fi gateway (sold separately) complete wifi configuration on WS View application. ...
4 channels water leak sensors. Channel 4. Setup Guide names can be edited both on the app and Ecowitt Weather Server. Battery power level display on the WS View 4.1 Install batteries 1.Remove the battery door on the back of the transmitter(s) by taking off the cover, as shown Fehler! Verweisquelle...
Page 10
2. Before inserting the batteries, find the dip switches instruction above battery compartment and set the sensor sensitivity level and channel number: Sensitivity Level: To change the sensor sensitivity of detection (High or Low), change Dip Switch 3, as referenced in Figure 3.
Page 11
be muted when the value equals to or lower 50PF. Low sensitivity: The water leakage alarm will be triggered when the detected water leak capacitance value equals to or over 90PF and be muted when the value equals to or lower 80PF.
Page 13
Switch in down position. Switch in up position. Figure 3: Dip Switch diagram...
Page 14
3.Insert two 1.5V AAA batteries. The LED indicator will turn on for four seconds and normally flash once every 60 seconds (the sensor transmission update period). Note: If no LED light up or is lighted permanently, make sure the battery is inserted the correct way or a proper reset is happened.
selected. 5.Close the battery door. 5. Sensor Placement Repeat additional remote transmitters(sold separately), verifying each remote is on a different channel. This device can be placed at multi locations include under-the-sink cabinet in a kitchen or bathroom, near a water heater, a basements, a sump pump, a toilet, a washer, a humidifier, an AC unit, or ice-making refrigerator.
DP1500 Wi-Fi Gateway (sold separately). 6.1 Pair with Gateway If the DP1500 has been in operation, and you have never had any DP70 multi-channel water leak sensor(s) setup before, just power up the sensor(s) and DP1500 will pick the sensor data automatically.
Page 17
If one DP70 sensor has been hooked on DP1500 before, and you have a new DP70 sensor to replace the old one, just power off the old sensor and power on the new sensor, the gateway will pick up the new sensor data automatically.
6.2 Wi-Fi Connection for the Gateway For this part, please refer to the manual of the 7. View Online Data with WS View DP1500 Wi-Fi gateway. Any question, please contact the customer service. When the Wi-Fi configuration is done, you may view leakage detection condition as well as the sensor battery level on WS view App at the live data page.
Note: It requires your phone and the gateway using the same network to view your sensor data on the WS View app. To remote monitor the sensor data, please upload the data to the free Ecowitt Weather Server: https://www.ecowitt.net. 8. Set Email Alerts Detailed operation instructions can be found on the DP1500 manual.
Page 21
Ecowitt Weather server, you may set alerts for the water leak sensor(s) on the website to get email notifications.
Page 24
Note: Once water seepage is detected, the device will emit 90dB alarm, and the ecowitt.net will push email alerts at the same time. General safety instructions Danger of asphyxiation: Keep all packaging materials (plastic bags, rubber bands, etc.) away from children. There is a danger of suffocation! Danger of burns:...
Page 25
Caution! Leaking / leaking battery acid can lead to burns! Avoid contact of battery acid with eyes, mucous membranes and skin. In case of contact, rinse the affected areas immediately with clear water and consult a doctor. Risk of electric shock: Children must not be unattended with the device, because the device contains electronic parts which are operated by means of a power source.
Page 26
short-circuit the unit or batteries. Never throw the device or batteries into a fire! Overheating and improper handling may result in short circuits which can cause fires and explosions. Important: If there is a defect, contact your dealer immediately. Never disassemble the device! The dealer will contact the service department.
Page 28
Notes on the return of batteries according to §12 BatterieVO: Batteries do not belong in the household waste. Please dispose of all batteries as required by law, disposal in domestic waste is expressly prohibited. Batteries and rechargeable batteries can be dispensed free of charge at municipal collection points or in the shops on the spot.
Page 29
This manual may contain errors and misprints. However, the information in this manual is regularly reviewed and corrections made in the next issue. We accept no liability for technical errors or printing errors, and their consequences. All trademarks and copyrights are acknowledged. www.froggit.de...
Page 30
HS Group GmbH & Co. KG Escherstr.31 50733 Koeln Germany...
Page 31
Telefon 0221 / 367 48 05 E-Mail info@hs-group.de Registergericht Amtsgericht Koeln HRA 26493 Komplementaer: Group Verwaltungsgesellschaft mbH Sitz Koeln Registergericht Amtsgericht Koeln HRB 64734 Geschaeftsfuehrer: Peter Haefele, Carl Schulte UStId DE237971721 WEEE Reg. Nr. 66110125...
Page 32
Hereby we declare, HS-Group GmbH & Co.KG, Escherstr. 31, 50733 D-Cologne, that this product is in compliance with the essential requirements other relevant provisions Directive 2014/53/EU. The declaration of conformity for this product can be found at: www.froggit.de or on request.
Need help?
Do you have a question about the DP70 and is the answer not in the manual?
Questions and answers