This instrument was developed for protecting persons and properties that may be subject to strong winds. It consists of 2
parts:
1.
A display unit of the wind force, with 4 programmable warning thresholds.
2.
A multidirectional turbine (wind sensor) enabling measurement of the wind in the horizontal plane and in the vertical as
well (turbulence behind objects). The turbine sends its signal magnetically to a transducer located at the end of the cable
connected to the display. This transmission system simplifies the installation process.
The SKYWATCH WWS operates from two 1.5 V batteries of type LR6/AA/AM3 (sufficient for over 2 years without replacement)
and equally well from an external supply of 6 to 30 VDC (cigar lighter socket, mains power etc.). When an AC-DC adapter is
connected, the batteries are disconnected. If the power fails, the batteries automatically take over.
INSTALLATION
Install the display housing with the fixing clamp, sheltered from the rain and from excessive humidity.
Install the turbi
ne in an open location and sufficiently far from any wall or any other obstacle to the wind, to ensure
greatest accuracy for the measurements.
Connect the cable t
Install the cable up to the turbine.
Position the transducer on the end of the cable close to the impeller, and preferably perpendicular to its axis of rotation.
PARAMETERS SETTING
The following parameters can be modified:
-
The 1
maximum threshold (Max1) for the alarm
st
-
The 1
minimum threshold (Min1) for the alarm
st
-
The 2
maximum threshold (Max2) for the alarm
nd
-
The 2
minimum threshold (Min2) for the alarm
nd
-
The units of windspeed
-
The impeller model
-
The sound level of the alarm
To modify the parameters, press the
can now be set for the alarm Max1. To modify the value, press briefly on the button
to reduce it. To move through the values more quickly, keep the button
go to the next adjustment by pressing the button
Then adjust the alarm threshold Min1 in the same way. Press the button
Press the button
and select a unit of measurement for the windspeed by using the
the button
. Now select the impeller model Pr1 (WindSENS3D, default impeller) or Pr2 (WindSENS12, WindSENS20 or
WindSENS60). Press the button
To finish, press the button
SKYWATCH
Wind Warning System
Instructions for use
o the housing.
and
and set the alarm intensity So1 (low) or So2 (high).
. SKYWATCH WWS will then return to normal mode and display the current windspeed.
WWS
®
Wind
Max1
Operating point of the
Min1
buttons together for 2 seconds and then release them. A new threshold
.
Displayed value = maximum recorded value
alarm
Displayed value = minimum recorded value
to increase and on the button
or
pressed. When the desired value is reached,
to adjust the alarm threshold Max2, then for Min2.
and
buttons. Validate by pressing
Time

Advertisement

loading

Summary of Contents for JDC Instruments SKYWATCH WWS

  • Page 1 This transmission system simplifies the installation process. The SKYWATCH WWS operates from two 1.5 V batteries of type LR6/AA/AM3 (sufficient for over 2 years without replacement) and equally well from an external supply of 6 to 30 VDC (cigar lighter socket, mains power etc.). When an AC-DC adapter is connected, the batteries are disconnected.
  • Page 2 FURTHER INFORMATION The SKYWATCH WWS transducer is sensitive to magnetic fields. This enables it to detect the small magnetic pulses sent by the magnet on the axis of the impeller, process them electronically and display the results on the LCD. Because of this sensitivity, SKYWATCH WWS may display values when it is near a magnetic field (coming, for example, from an electric motor, a computer or electric lighting).