Reece VADA V-PC Quick Manual

Reece VADA V-PC Quick Manual

Auto pressure control

Advertisement

Quick Links

SPECIFICATIONS
Technical Data
Supply voltage
Max Power
Max Current
Protective rating
Max operating pressure
Cut-In
Max. Water temperature
Inlet/Outlet
Auto Pressure Control Pressure Loss
18
16
14
12
10
8
6
4
2
0
0
50
Flow (litres/minute)
WARRANTY & CARE DETAILS
Dear Customer,
This is the warranty by Reece Pty. Ltd. relating to your product.
Please keep it together with your purchase receipt. In the event of a
query please contact your nearest Reece Plumbing Centre.
Warranty
You have purchased a quality product from Reece Australia. This
product is covered by a 12 month warranty. This warranty covers
faults in the product construction, material and assembly. Faulty
products will be repaired or exchanged free of charge. Faulty items
become our property.
Please note that every product is subject to a stringent final inspection
before it is delivered.
This warranty does not include faults caused by
• Unsuitable or improper use
• Incorrect installation
• Normal wear and tear
• Inadequate or complete lack of maintenance
• Chemical, electrochemical or electrical influences.
Disclaimer:
The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions and
set-outs listed are correct at time of publication however the manufacturer distributor takes no responsibility for printing errors.
VADA - V-PC Auto Pressure Control
240 V ~ 50 Hz
1.5 kW
8 A
IP 65
1 MPa
150 kPa
65°C
1" BSP Male
100
150
It is hereby declared that the item below conforms with the following directives:
• AS/NZS CISPR14 AS/NZS 60335.1 AS/NZS 60335.2.41
Warranty repairs may only be performed by our service representa-
tives or an authorised customer service workshop.
Any attempt to repair the device by the customer or unauthorised
third parties shall terminate the warranty.
Any warranty service granted by Reece will neither extend the period
of the warranty nor will any new warranty period be justified for any
parts repaired or replaced by us.
To the maximum extent permitted by law, Reece excludes all warran-
ties other than those set out above. In the event of a warranty claim,
we will replace or repair defective products, or pay for the cost of
having defective products repaired or replaced, but will not be liable
for any injury to any person, damage to any property, any indirect or
consequential loss, or in any other respect.

Advertisement

loading
Need help?

Need help?

Do you have a question about the VADA V-PC and is the answer not in the manual?

Questions and answers

Summary of Contents for Reece VADA V-PC

  • Page 1 WARRANTY & CARE DETAILS Dear Customer, This is the warranty by Reece Pty. Ltd. relating to your product. Warranty repairs may only be performed by our service representa- Please keep it together with your purchase receipt. In the event of a tives or an authorised customer service workshop.
  • Page 2 VADA - V-PC Auto Pressure Control Installing the Auto Pressure Control Correctly It is advisable to connect the pressure control to the If the column of water between the pump and system by means of a flexible hose. the highest tap exceeds 15m, the unit cannot be installed directly on the pump, it has to be raised until the column of water between the unit and highest tap does not exceed...
  • Page 3 VADA - V-PC Auto Pressure Control 1. Pressure Control Installation The Vada Auto Pressure Control comes fully wired and is ready for use with the pump. Please ensure the pumps current rating is below 10 amps or that the automatic pump control is configured so as the current to the unit is less than the maximum current rating of 10 amps. Warning: Never take the electronic board out of the control box. The wiring diagram inside the front panel will show you how to make correct connection.
  • Page 4 VADA - V-PC Auto Pressure Control TROUBLESHOOTING - Auto Pressure Control Trouble Cause related to Pressure Control Causes not related to pressure control Pump won’t start • The electronic card is broken • Voltage failure • Pump jammed • Electric cables inverted (line/motor) Pump won’t stop • The electronic card is broken • Presence of leaks which are higher than the minimum flow of 0.6 • The reset button is blocked l/min • The flow detector is blocked in the upper position • The pump does not provide sufficient pressure Intermittent pump working • The elctronic card is broken • Presence of leaks which are higher than the minimum flow of 0.6 • The pump does not provide sufficient l/min pressure Pump is jammed...