Pure Comfort DET-215 Owner's Manual

Pure Comfort DET-215 Owner's Manual

Tempa check infrared thermometer

Advertisement

T
C
I
EMPA
HECK
NFRARED
Owner's Manual
Model
Contents
Introduction
......................................................02
............................................... 05
..............................................08
....................................................17
.............................................19
.....................................................22
.................................................23
Calibration .............................................................25
.............................................................26
.............................................................27
..................................................28
1
T
HERMOMETER
DET-215
........................................... 03
...................................... 04
............................ 06
..........................................09
.................................15
............................18
..........................................21
Introduction
The multi functional thermometer is intended solely for measuring
forehead temperature, ear temperature and object temperature. It
allows you to quickly and easily measure body temperature and
object temperature. It converts the measured heat into a temperature
reading displayed on the LCD. Infrared Thermometer is intended
for the intermittent measurement of human body temperature by
people of all ages.
Please read all instructions carefully and thoroughly
before using this product.
Warning:
1.
The devices are reusable for home use only.
It's not meant to replace a visit to the doctor. Please
consult with doctor if you have health concerns.
2. There is no gender or age limitation for using multi
functional thermometer. This thermometer can be reused by
many people.
3. Do not allow children to take their temperatures unsupervised,
some parts are small enough to be swallowed.
4. Never immerse this device in water or other liquids(not
waterproof).
5.Do not modify this equipment without authorization of
manufacturer.
6. Do not expose the thermometer to temperature extremes
(below -25℃/-13
or over 55℃/131
humidity (>95%RH).
7. Keep the battery away from children.
8
. Remove battery from the device when not in operation for
a long time.
Document No.: JDET-0504-002
Article No.: 002
Version: F
Date of Issue: 2020-01
) nor excessive
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DET-215 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pure Comfort DET-215

  • Page 1: Table Of Contents

    EMPA HECK NFRARED HERMOMETER Owner's Manual DET-215 Model Document No.: JDET-0504-002 Article No.: 002 Version: F Date of Issue: 2020-01 Contents Introduction The multi functional thermometer is intended solely for measuring Introduction ............02 forehead temperature, ear temperature and object temperature. It Product Description ...........
  • Page 2: Product Description

    Product Description LCD Display Introduction 1. Forehead Cover 2. Probe 3. START Button Button 5. S Button 6. Battery Cover AM and PM sign in Time mode Time and date Low voltage sign Object temperature mode Ear temperature mode Memory mode Unit sign: ℃...
  • Page 3: Body Temperature

    Body Temperature Real Time Clock Setting The temperature of a healthy person is affected by various factors: ④ Set the year the person’s individual metabolism, their age(body temperature is Press and release the S BUTTON to advance one year until the correct year appears. higher in babies and toddlers and decreases with age.
  • Page 4 Illustration For Use Illustration For Use To measure ear temperature: . The measured value appears on the display and the end of the measuring is signalled by a short beep. Some people produce different readings in their left and right ear. ●...
  • Page 5: Temperature Taking Hints

    Temperature Taking Hints Temperature Taking Hints 5. Do not take temperature over scar tissue, open sores or abrasions. To ensure that the reading always reflects the body temperature 6. Don't take a measurement while or immediately after nursing a accurately, you need to take account of the following factors which baby.
  • Page 6: Care And Cleaning

    Care And Cleaning Care And Cleaning For cleaning: 1. The probe window must be kept clean, dry, and undamaged at all 1)Soak a clean soft cloth in drinking water, wring it out and then times to ensure accurate readings. The accuracy of temperature wipe the thermometer(including probe) no less than 3 times;...
  • Page 7: Troubleshooting

    Troubleshooting Troubleshooting Error message Error message Problem Solution Problem Solution In Ear/Forehead mode: Take a measurement Measurement before Temperature taken is until thermometer is Read Temperature Taking higher than 43.0 ℃ thermometer is ready ready(with 2 beeps). Hints Thoroughly, then (109.4℉).
  • Page 8: Warranty

    Warranty FCC Information Caution: Changes or modifications to this unit not expressly This appliance conforms to the following standards: approved by the party responsible for compliance could void the ASTM E1965-98 Standard Specification for Infrared Thermometers user authority to operate the equipment. for Intermittent Determination of Patient Temperature, *Note: ISO 80601-2-56 Medical electrical equipment —Part 2-56:...
  • Page 9 Electromagnetic Compatibility Information Electromagnetic Compatibility Information Electromagnetic Compatibility Information Electromagnetic Compatibility Information Table 3 continued NOTE 1At 80 MHz and 800 MHz, the higher frequency range applies.NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a The ISM(industrial, scientific and medical) bands between 0,15 MHz and 80 MHz are 6,765 MHzto6,795 MHz;13,553 MHz to 13,567 MHZ;26,957 MHz to 27,283 MHz;...
  • Page 10 Electromagnetic Compatibility Information Electromagnetic Compatibility Information WARNINGS! · This device should not be used in the vicinity or on the top of other electronic equipment such as cell phone, transceiver or radio control products. If you have to do so, the device should be observed to verify normal operation.