Advertisement

Quick Links

ASU-0000-009 - Air Isolation Unit Manual
It is essential for safety that the installer and user of the Expo system observe
(N.B. These instructions apply only to the Pressurizing system. It is the responsibility of the manufacturer
of the Pressurized Motor Enclosure to provide appropriate instructions for the Enclosure.)
Contents
1. ASU-0000-009 - General System Specification 
2. Quick User Guide 
3. Application Suitability 
4. Description and Principle of Operation 
5. Main Components 
6. Installation of the System 
7. Commissioning 
8. Maintenance of the System 
9. Fault Finding 
10. Recommended Spares List 
11. Drawings and Diagrams 
ML576 | v2
ML576
IMPORTANT NOTE
the following instructions:
Please refer to the standard for principles and definitions.
28-Feb-2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ML576 and is the answer not in the manual?

Questions and answers

Summary of Contents for EXPO ML576

  • Page 1 ASU-0000-009 - Air Isolation Unit Manual ML576 IMPORTANT NOTE It is essential for safety that the installer and user of the Expo system observe the following instructions: Please refer to the standard for principles and definitions. (N.B. These instructions apply only to the Pressurizing system. It is the responsibility of the manufacturer of the Pressurized Motor Enclosure to provide appropriate instructions for the Enclosure.)
  • Page 3: Technical Specifications

    (i.e. above ground) and the hazard is caused by flammable gases, vapours or dust. The following are main materials of construction of the Air isolation unit. If substances that will adversely affect any of these materials are present in the surrounding environment, please consult Expo for further guidance. Materials of construction: ...
  • Page 4: Description And Principle Of Operation

    The Air isolation unit must be installed by a competent person in accordance with relevant standards, and local codes of practice. Copies of the Current Standard can be purchased from Expo Technologies or B.S.I or relevant local code / Standard.
  • Page 5 Solid Particles 0.5 μm < particle size ≤ 1 μm, maximum 1000 particles / m3 Residual Water 1μm maximum density, +3 C* pressure dewpoint Oil Content ≤ 0.01 mg / m3 concentration total oil ML576 | v2 Page Expo Technologies UK Expo Technologies US...
  • Page 6: Maintenance Of The System

    If the system does not behave in the manner described above there is a fault. Some of the more likely faults are dealt with below. If a cure cannot be affected by following the procedure shown below please call Expo (24 hour answering) or your supplier for further assistance.
  • Page 9 [This Page Intentionally Left Blank] ...
  • Page 10 [This Page Intentionally Left Blank] ...
  • Page 11 [This Page Intentionally Left Blank] ...
  • Page 12 Expo Technologies USA Expo Technologies UK Expo Technologies China Expo Technologies Inc. Expo Technologies Ltd. Qingdao Expo M&E Technologies Co. Ltd 9140 Ravenna Road Unit #3 Unit 2 The Summit, Hanworth Road 329 Huashan Er Lu Sunbury-On-Thames, Jimo City, Qingdao,...