Quick Start Guide
®
INSTEON
Micro Shutter
Model: 2444-222/2444-422/2444-522
About INSTEON Micro Shutter
Congratulations on your purchase of the INSTEON ® Micro
Shutter! This compact module wires in behind an existing wall
switch to give you complete—and completely hidden—remote
control over your motorized window shutters.
Note: Installation should only be performed by a qualified
electrician or a homeowner who is familiar and comfortable with
electrical circuitry. If you have questions, consult an electrician or
call the INSTEON Support Line at 800-762-7845.
In the Box
- INSTEON Micro Shutter
What's Needed
- Flathead screwdriver
Installing INSTEON Micro Shutter (Dual Momentary Switch)
1)
Before installing, write down Micro Shutter's INSTEON I.D. (on sticker) for future reference.
2)
Turn off breaker/fuse
3)
Remove wallplate and unscrew existing switch.
4)
Gently pull switch out of wall and disconnect wires.
5)
After ensuring that the wires are not touching, turn breaker back on.
6)
Use a voltage meter to identify the fixture's Line, Load and Neutral wires.
7)
Turn off breaker again.
8)
Connect Micro Shutter wires as follows:
Terminal #1
Terminal #2
Terminal #3
Terminal #4
Yellow wire
Purple wire
9)
Turn breaker back on.
Connected load will turn on and Micro Shutter's LED will turn on green.
10) Test connection by tapping Micro Shutter's on/off buttons.
Connected load will turn on and off and Micro Shutter's LED will turn
1
If multi-gang box, turn off all breakers/fuses that may be supplying power to the box.
2
If the wires cannot be detached, cut wires where they enter the switch and strip ½" of insulation off the ends.
2444-222 Rev. 5/17/2012 1:56 PM / See Owner's Manual for Warranty Information.
Protected under U.S. and foreign patents (see www.insteon.com)
© Copyright 2012 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845
- Philips screwdriver
1
and verify that the power is off.
Micro Shutter
Micro Shutter
Terminal #1
(Line)
Set button
- Wire cutter/stripper
2
House
Line (100-277VAC)
Load (light, fan, etc.)
Neutral
Neutral
Switch
Momentary on/brighten
Momentary off/dim
green
Set button
Terminal #2
(L1 Load, up)
Terminal #3 (L2
Load, down)
Terminal #4
(Neutral)
- Voltage meter
(on) and
red
(off).
Off button
On button
Need help?
Do you have a question about the 2444-222 and is the answer not in the manual?
Questions and answers