IMPORTANT SAFETY INSTRUCTIONS
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It is
the owner's and installer's responsibility to read and comply with
all safety information and instructions accompanying these sym-
bols. Failure to heed safety information increases the risk of
personal injury, property damage, and/or product damage.
HIGH VOLTAGE!
D
ALL
ISCONNECT
POWER BEFORE SERVICING OR
. M
INSTALLING THIS UNIT
ULTIPLE POWER SOURCES
. F
MAY BE PRESENT
AILURE TO DO SO MAY CAUSE PROPERTY
,
DAMAGE
PERSONAL INJURY OR DEATH
T
HE MANUFACTURER WILL NOT BE RESPONSIBLE FOR INJURY OR
PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE
. I
PROCEDURES
F YOU INSTALL OR PERFORM SERVICE ON THIS UNIT
ASSUME RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY
DAMAGE WHICH MAY RESULT
TO INSTALL OR SERVICE HEATING AND AIR CONDITIONING EQUIPMENT
O
NLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL
(
, "
")
REPAIR
HEREINAFTER
SERVICE
SHOULD SERVICE THE EQUIPMENT
FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR
. I
SERVICE PROCEDURES
F YOU SERVICE THIS UNIT
FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY RESULT
JURISDICTIONS THAT REQUIRE ONE OR MORE LICENSES TO SERVICE THE EQUIPMENT
,
SPECIFIED IN THIS MANUAL
ONLY LICENSED PERSONNEL SHOULD SERVICE THE
. I
EQUIPMENT
MPROPER INSTALLATION
THE EQUIPMENT SPECIFIED IN THIS MANUAL
SERVICE OR REPAIR THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT PROPER
TRAINING MAY RESULT IN PRODUCT DAMAGE
.
INJURY OR DEATH
IO-416F
11/2016
.
. M
ANY JURISDICTIONS REQUIRE A LICENSE
,
,
ADJUST
SERVICE OR
THE EQUIPMENT SPECIFIED IN THIS MANUAL
. T
HE MANUFACTURER WILL NOT BE RESPONSIBLE
,
YOU ASSUME RESPONSIBILITY
. I
N ADDITION
,
,
ADJUSTMENT
SERVICING OR REPAIR OF
,
OR ATTEMPTING TO INSTALL
,
,
PROPERTY DAMAGE
PERSONAL
CO can cause serious illness including permanent brain
damage or death.
,
YOU
Advertencia especial para la instalación de calentadores ó manejadoras
.
de aire en áreas cerradas como estacionamientos ó cuartos de servicio.
Las emisiones de monóxido de carbono pueden circular a través
del aparato cuando se opera en cualquier modo.
El monóxido de carbono puede causar enfermedades severas
,
IN
como daño cerebral permanente ó muerte.
RISQUE D'EMPOISONNEMENT AU MONOXYDE DE CARBONE
,
,
ADJUST
Cette ventilation est nécessaire pour éviter le danger d'intoxication
au CO pouvant survenir si un appareil produisant du monoxyde
de carbone continue de fonctionner au sein de la zone confinée.
B10259-216
B10259-216
B10259-216

Advertisement

Table of Contents
loading

Summary of Contents for Amana ACNF180 Series

  • Page 1 CEILING MOUNT AIR HANDLERS INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and comply with all safety information and instructions accompanying these sym- bols.
  • Page 2: Shipping Inspection

    This ceiling mount air handler is available in cooling capacities of 1.5, 2 and 2.5 nominal tons of cooling with a PSC motor (ACNF18, ACNF24 and ACNF30) and 2 and 2.5 nominal tons of cooing with a constant torque (EEM) motor (ACNF25 and ACNF31). Electric heat models are available in capacities of 0, 5, 6, 8 and 10 kW.
  • Page 3 Filters Drain Connection Filters are not provided with unit, and must be supplied and in- stalled in the return air system by the installer. A field installed filter grille is recommended for easy and convenient access to the filters for periodic inspection and cleaning. Filters must have 2"...
  • Page 4 BRANCH CIRCUIT COPPER WIRE SIZE (Base on 1% Voltage Drop) SUPPLY WIRE 150 TW (60C) LENGTH - FEET BRANCH CIRCUIT AMPACITY Note: W iring for unit only, no heat k it installed. Table 1 For more than three conductors in a raceway or cable, see the N.E.C.
  • Page 5: Special Instructions

    IMPORTANT NOTE: Torch heat required to braze tubes of various sizes is proportional to the size of the tube. Tubes of smaller size require less heat to bring the tube to brazing temperature before adding brazing alloy. Applying too much heat to any tube can melt the tube.
  • Page 6: Electrical Connections

    ELECTRICAL CONNECTIONS 24 V CONNECTIONS BLUE YELLOW TO CONDENSING UNIT HIGH VOLTAGE! ISCONNECT POWER BEFORE SERVICING ULTIPLE POWER SOURCES MAY BE PRESENT AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH DUE TO ELECTRIC SHOCK IRING MUST CONFORM WITH AND ALL LOCAL CODES NDERSIZED WIRES COULD CAUSE POOR EQUIPMENT PERFORMANCE...
  • Page 7: Maintenance

    Air Filter(s) CONSTANT TORQUE (EEM) MOTORS All central air moving comfort systems must include air filter(s). ACNF25 and ACNF31 models utilize constant torque (EEM) mo- Locate these filters in either the equipment or return air duct sys- tors. These motors come with a separate control box which is tem upstream of the equipment.
  • Page 8 They are simple to service and forgiving to operate. We use quality materials and components. Finally, every unit is run tested before it leaves the factory. That’s why we know. . .There’s No Better Quality. Visit our website at www.daikincomfort.com, www.goodmanmfg.com or www.amana-hac.com for information on: •...