/ vacuum pump, single-stage and two-stage, with side channel SER MANUAL (version 2018 v1) Thank you for purchasing the INW series ring blower / vacuum pump. Read this manual carefully before using the product. INW blowers/pumps comply with the conditions of Europe-...
Safety valve ......................10 Manometer ......................11 Backflow valve ......................11 Recommended installation of the INW blower/pump with accessories: ......11 9 Waste disposal ....................... 11 10 Warranty ......................... 12 For current information about the company and its products, visit www.in-eco.eu. info@in-eco.eu www.in-eco.eu...
1.1 G ENERAL Manual This user manual is the intellectual property of IN-ECO, spol. s.r.o. All rights are reserved. The current version of the manual is available at www.in-eco.eu. Equipment Within the scope of this manual, equipment or electrical equipment is considered the ring blower or vacuum pump with a side channel.
IN-ECO, spol. s r.o. IN-ECO RING BLOWER - User manual Version 2012.01 AFETY Handling the equipment in an unprofessional manner may lead to heavy or even fatal injuries! Read this manual carefully before performing any operations with the INW ring blower/ vacuum pump. The manual must be absolutely clear.
For specific technical parameters, visit www.in-eco.eu, some of which can also be seen on the equipment label. The technical pa- rameters of the equipment, namely the maximum pressure difference and suction power, stated on the www.in-eco.eu website and on the label are valid under the following conditions (nominal values):...
INW ring blower / vacuum pump only according to the conditions specified by its parameters, which are alsoavailable at www.in-eco.eu. This particularly concerns the ambient temperature and the sucked gas, maximum pressure difference and level of electrical coverage. Placement Place the equipment in a well-ventilated area with sufficient air circulation.
IN-ECO, spol. s r.o. IN-ECO RING BLOWER - User manual Version 2012.01 Tab. 1: Temperature increase depending on pressure difference – ring blowers with side channel: ∆ Pressure differ- ence [mbar] ∆ 15-20 30-55 50-80 70-110 90-100 T [°C] Single-stage ∆...
Use electrical wires of the proper strength (section) according to the electrical specifications for the specific blower/pump stated in the catalog sheets on the www.in-eco.eu website. The wiring diagram is on the cover of the terminal box. First, connect the grounding wire correctly. Make sure to protect against short circuits and equipment overloading.
The maximum possible pressure difference in the system must not be greater than the maximum pressure difference of the equipment stated in the catalog sheet on the www.in-eco.eu website or on the product label. Otherwise the equipment is critically overloaded. The common operating pressure in the system should be at least 10% lower than the maximum working pressure on the product label or catalog sheet of the equipment.
ERVICE Repairs shall only be carried out by an authorized IN-ECO service center during the warranty period. All war- ranty rights are forfeited if the equipment is tampered with during the warranty period. Have an authorized IN- ECO service center service INW ring blowers / vacuum pumps after the warranty has expired.
IN-ECO, spol. s r.o. IN-ECO RING BLOWER - User manual Version 2012.01 tected against overloading. (The maximum working pressure is usually 7-15% lower than the maximum pres- sure stated on the product label.) 8.3 M ANOMETER Install a manometer for the purpose of fundamental pressure ratio diagnostics.
> if the warranty conditions are not respected, HANK YOU Thank you for purchasing the INW series ring blower / vacuum pump. We hope you will be satisfied. Do not hesitate to contact us if you have any questions. info@in-eco.eu...