Advertisement

Quick Links

Specifications:................................................1
Introduction:...................................................2
Scope of this Manual.....................................2
Description:....................................................2
Features.....................................................2
Items Included with Unit.................................. 2
Installation:..................................................... 2
Pipe Installation............................................ 2
Physical Unit Installation.................................. 2
Securing the Mounting Bracket...................2
Exhaust Pipe.......................................... 3
Wiring.......................................................... 3
Power Cables......................................... 3
Conduit Usage........................................ 3
FAAST 8251BPI System Powering...................4
FAAST 8100 System Powering .................... 5
User Interface:................................................. 6
FAAST 8251BPI User Interface....................... 6
FAAST 8100 User Interface............................6
User Interface Card Installation........................ 6
Particulate Level Display................................. 6
Alarm Level Display ......................................7
Air Flow / Fault Display.................................. 7
Labels................................................... 7
User Interface Buttons...................................7
Document Colour Code Key:
Black:
applies to both 8251BPI and 8100 Devices
Orange: applies to 8251BPI FAAST XM Only
Green:
applies to 8100 FAAST XM Only

SPECIFICATIONS:

Electrical Characteristics
External Supply Voltage
Remote Reset Time
Power Reset
Average Operating Current
Alarm Current
24V
DC
Average Loop Driver Operating Current:
Loop Driver Voltage Range:
Relay Contact Ratings
Environmental Ratings
Operating Temperature
Sampled Air Temperature
Humidity
IP Rating
Coverage Area
Air Movement
Mechanical Characteristics
Exterior Dimensions
Cable Access
Wire Gauge
Shipping Weight
Nett Weight
Pipe Network Size
Maximum single pipe length
External pipe diameter
Internal pipe diameter
FAAST 8251BPI and 8100
INSTALLATION AND MAINTENANCE INSTRUCTIONS

TABLE OF CONTENTS

(refer to Page 24)
18 - 30V
DC
External monitor must be pulled low for a minimum of 100msec.
10 secs (FAAST
500mA @ 24V
650mA - All relays active, all alarm levels displayed. Voltage @
700uA
15 - 32V
DC
3.0A @ 30V
0°C to 38°C
-20°C to 60°C
10 to 95% (non-condensing)
IP30
2
1000m
0 - 1,219.2 m/min.
337 x 330 x 127
4 x 25.4mm cable entry holes on top and bottom of unit.
2.0mm (12 AWG) max to 0.5mm (24 AWG) min.
5.26 kg, includes packing material
Up to 1000m
80m
25mm
15 - 21mm
1
Modes of Operation:........................................ 8
Initialisation..................................................8
Startup.......................................................8
Configuration............................................... 8
Normal Mode................................................8
Test Mode................................................... 8
Reset Mode................................................. 8
Acclimate....................................................9
Setting Acclimate Mode............................ 9
Day, Night and Weekend Mode........................9
Isolate......................................................... 9
Disable....................................................... 9
User Button Alternate Functions.....................10
Passcode Access...................................10
Address Blink Mode................................10
IP Address Blink Mode............................11
Real-Time Clock..........................................11
Logs...........................................................11
Event Log............................................. 11
Data Trend Log...................................... 11
Message Log........................................ 11
External Monitor / Reset............................. 11
Ethernet Connection.................................. 11
Faults..................................................... 12
Pipe Network............................................. 13
Web Server............................................... 13
Email Notification........................................ 13
Canned Smoke Tests.................................. 13
Maintenance................................................... 13
FAAST XM Detector Base............................. 13
Glossary:.......................................................14
Key Terms................................................. 14
Document Colour Code Key....................... 14
FAAST System Validation Form....................... 15
8251BPI);
1 sec (FAAST 8100)
DC
, 0.5A @ 125V
DC
AC
(32°F to 100°F)
(-4°F to 140°F)
2
(8,000ft
)
(0 - 4,000 ft./min.)
H x W x Dmm
2