Advertisement

Quick Links

Operation & Maintenance Manual
FRED MINI-VAC II
READ AND SAVE THESE INSTRUCTIONS
Visit our Website for more information on this product
www.diversitech.ca
1200 55
th
Avenue, Montreal, Quebec H8T 3J8
Tel: 1.800.361.3733 | Fax: 1.514.631.9480 | info@diversitech.ca

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MINI-VAC2-010N1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DIVERSITECH MINI-VAC2-010N1

  • Page 1 Operation & Maintenance Manual FRED MINI-VAC II READ AND SAVE THESE INSTRUCTIONS Visit our Website for more information on this product www.diversitech.ca 1200 55 Avenue, Montreal, Quebec H8T 3J8 Tel: 1.800.361.3733 | Fax: 1.514.631.9480 | info@diversitech.ca...
  • Page 2: Table Of Contents

    Table of Contents SECTION 1 – SAFETY PRECAUTIONS OF FUME & DUST EXTRACTION/COLLECTION ..............................3 1.1 Symbols ...........................................................3 1.2 User Responsibility ....................................................3 1.3 Fume Extraction Hazards ..................................................3 1.4 Dust Collection Hazards ..................................................3 1.5 Safety Stickers ......................................................4 SECTION 2 – SPECIFICATIONS ........................................................4 2.1 Diagram &...
  • Page 3: Section 1 - Safety Precautions Of Fume & Dust Extraction/Collection

    • Never use or install equipment where the potential for combustible fumes or dusts are present without a fire/explosion protection system. • If you are unsure if the product you purchased is correct for your application, call Diversitech at 1-800-361-3733.
  • Page 4: Safety Stickers

    Filter Area (sq. ft.) Reusable Efficiency 16” Nanofiber Filter Standard S-MV2-0001 MERV 15 16” Spunbond Poly Filter Optional S-MV2-0002 MERV 11 16” HEPA Filter Optional S-MV2-0003 MERV 17 For information on inspecting and cleaning filter, or purchasing replacement filters, contact Diversitech at 1-800-361-3733.
  • Page 5: Section 3 - Pre-Installation

    SECTION 3 - PRE-INSTALLATION 3.1 To Setup or Install Safely • Do not place unit near flammables or combustible surface. • Refer to Section 2: Specifications, to know the electrical requirements of the unit you are installing and ensure adequate input power that is properly sized, rated, and protected. •...
  • Page 6: Section 4 - Operation

    • Do not use product without first confirming if a Spark Arrestor is required and installed for the type of dust, or fumes you are extracting and/or collection. If you are unsure, call a Diversitech representative at 1-800-361-3733. 4.2 Controls •...
  • Page 7: Failure Event

    4.5 Failure Event If, for some reason, during operation there is an accident, a blockage occurs, or the suction arm begins to malfunction, the operator should immediately shut off the machine. This is considered a machine failure and the following steps should be taken: This product consists of four basic components: Turn the power switch to the OFF position.
  • Page 8: Tools Required

    5.2 Tools Required REPLACEMENT RESPIRATOR GLOVES FILTER PROTECTION AIR GUN (if required) 5.3 Routine Maintenance Schedule The manufacturer recommends the following routine maintenance based on light-duty use in normal operating conditions. Service more frequently if the unit is used in severe conditions. Frecuency Manual Reference Pre-Use...
  • Page 9: To Troubleshooting Procedure

    INTERMITTENTLY Power Operating Maintenance (Section 5.3) Motor Motor Operating Operating Filter Indicator Light Perform Filter Service (Section 5.) Air Flow Restricted Call for Service Call for Service 1(800)361-3733 1(800)361-3733 support@diversitech.ca support@diversitech.ca Inspect/Clear Debris from Nozzle & Hose Unit Operates Properly...
  • Page 10: Appendix 1 - Electrical Diagram Manual

    APPENDIX 1 - ELECTRICAL DIAGRAM MANUAL [120v] Single-Phase Power ELECTRIC Disconnect power before performing any maintenance on unit, including filter inspection. The input power to this unit is high voltage, and touching any live SHOCK electrical parts can cause fatal shocks or severe burns. Do not touch live electrical HAZARD parts.
  • Page 11: Appendix 2 - Maintenance Record

    APPENDIX 2 - MAINTENANCE RECORD Diversitech Inc. authorizes this page to be photocopied or otherwise reproduced as needed for management of maintenance records. MANUFACTURER: DIVERSITECH INC. MODEL N° MINI-VAC II SERIAL N° SERVICE LOCATION: CONTROL N° Date Description of Service...
  • Page 12: Appendix 3 - Replacement Parts

    APPENDIX 3 - REPLACEMENT PARTS Mini-Vac II ITEM NUMBER DESCRIPTION S-MV2-0001 16” Nanotech XV Cartridge Filter, 55 sqft, MERV 15, MINI-VAC2 S-MV2-0002 16” Polytech XI Cartridge Filter, 44 sqft, MERV 11, MINI-VAC2 S-MV2-0003 16” HEPA Cartridge Filter, 40 sqft, MERV 17, MINI-VAC2 S-MV2-0005 Activated Carbon Panel Filter, MINI-VAC2 S-MV2-0010...
  • Page 13: Appendix 4 - Sample Safety Stickers

    APPENDIX 4 - SAMPLE SAFETY STICKERS The machine is marked with a wet filtration safety sticker to remind the operator of safe working practices: The machine is marked with safety stickers in appropriate places to remind the operator of safe working practices.
  • Page 14: Notes

    NOTES...
  • Page 15 NOTES...
  • Page 16: Limited Equipment Warranty

    Diversitech Inc. will repair or replace, at our option, any defective parts which fail during the warranty period. This warranty is limited to replacement parts ONLY, and does not cover personal liability, property loss, normal wear;...

Table of Contents