Taco Comfort Solutions Hot-Link HLS-2 Instruction Sheet

Taco Comfort Solutions Hot-Link HLS-2 Instruction Sheet

For domestic hot water recirculation

Advertisement

HLS-2 Hot-Link
SUPERSEDES: NEW
Plant ID# 001-4255

Application:

The Taco HLS-2 Hot-Link
Water recirculation ensures instant hot water comfort at
showers and faucets. By supplying fresh hot water to the
fixtures while returning the "cooled" hot water back to the
water heater through the cold line, it also saves thousands
of gallons of wasted water per year. The average family can
achieve yearly savings of up to 12,000 gallons of water nor-
mally wasted down the drain while waiting for hot water.
Hot
Cold
Additional Hot-Link®
Valve Locations
(2) new 1/2" x 1/2"
Taco® supplied ex lines
(female to female)
CITY WATER
SUPPLY
Hot-Link®
Circulator
Cold
Inlet
A Typical
Installation
with a
Mixing Valve
Water
Heater

High Quality Features:

The Hot-Link System includes a high performance
Stainless Steel 00 circulator with a pre-wired power cord
and programmable 24 hour timer. This circulator is suitable
for most residential homes with hot supply lines up to 150
feet in length.
The unique Hot-Link Valve is the key to the system. Made
of durable high temperature polymer, it creates an easy-to-
install return loop through the cold line from the furthest fix-
ture back to the water heater. An integral thermal sensor
disc closes when hot water reaches the valve. An internal
flow check prevents cold water from backing into the hot
line. Stainless steel braided flex hoses complete the instal-
lation.
WARNING: To avoid electrical shock, disconnect the
power supply to the circulator and the main
electrical unit.
WARNING: Circulator must be installed on and supported
by the circulation piping.
Instruction Sheet
System for Domestic Hot Water Recirculation
®
System for Domestic Hot
®
Hot
Cold
The Best Location
is furthest xture
from Hot Water Heater
Hot-Link® includes (2)
plastic wall anchors
and screws
1/2"
1/2"
Shut-O
Shut-O
Valve
Use (2) existing 3/8" x 1/2"
female to female ex lines
COLD WATER LINE
HOT WATER LINE

Installing the Hot-Link System Circulator:

1. Follow all local plumbing and electrical codes when
installing the Hot-Link System.
2. Shut off cold water supply valve to water heater.
3. Open a hot water faucet in the house to drain the hot
water line.
4. Open water heater drain valve located at the bottom of
tank to drain remaining hot water from the lines. It is not
necessary to drain the entire tank.
5. Disconnect hot water supply line at water heater outlet
nipple.
6. Install
" female tailpiece and union nut to the water
3
4
heater outlet. Apply pipe dope or Teflon tape to all male
threads as required.
7. Install the
3
4
pump outlet connection. Be sure flow arrow located on
the pump casing is in the proper direction. See diagram.
Valve
Mixing Valve
(optional)
8. Install the Hot-Link circulator by attaching the inlet to
the tailpiece and union nut on water heater outlet.
Circulator motor must be in the horizontal position.
CAUTION:
Permanent damage may result and will void
warranty.
9. Reconnect the hot water supply line to circulator
male outlet.
10. Open supply valve to water heater. Let water run until all
air is purged from lines. Check for any leaks. If leaks are
detected, close supply valve and tighten all connections.
11. Shut off open hot water faucet.
EFFECTIVE: October 30, 2015
" male union tailpiece and union nut to the
Do
not
run
circulator
A Taco resource – saving product
102-514
Hot-Link®
Circulator
dry.
"
3
4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hot-Link HLS-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Taco Comfort Solutions Hot-Link HLS-2

  • Page 1 Instruction Sheet 102-514 HLS-2 Hot-Link System for Domestic Hot Water Recirculation ® SUPERSEDES: NEW EFFECTIVE: October 30, 2015 Plant ID# 001-4255 Application: Installing the Hot-Link System Circulator: 1. Follow all local plumbing and electrical codes when The Taco HLS-2 Hot-Link System for Domestic Hot Water recirculation ensures instant hot water comfort at installing the Hot-Link System.
  • Page 2 4. Disconnect the hot and cold flex hoses from the ⁄ " faucet connections beneath the sink and reconnect Setting the Circulator Timer: 1. Set timer to exact time of day by turning the clock face them to the respective hot and cold inlet ports on the clockwise.
  • Page 3 Hot-Link Trouble Shooting SYMPTOM POSSIBLE CAUSE SERVICE TIP • Close angle stop valves beneath sink. • Open hot and cold faucets to drain line of pressure. cartridge Clogged filter screen. • Remove valve stem thoroughly clean screen, replace, open angle stop valves and check operation.
  • Page 4 LIMITED WARRANTY STATEMENT Taco, Inc. will repair or replace without charge not be covered by this warranty. (at the company’s option) any Taco 00 Series cir- If in doubt as to whether a particular substance THE ABOVE WARRANTIES ARE IN LIEU OF culator or circulator part which is proven defec- is suitable for use with a Taco product or part, or ALL OTHER WARRANTIES, EXPRESS OR...

Table of Contents